Simulated workplace performance of N95 respirators

被引:44
作者
Coffey, CC [1 ]
Campbell, DL [1 ]
Zhuang, ZQ [1 ]
机构
[1] NIOSH, Dept Hlth & Human Serv, Publ Hlth Lab, Ctr Dis Control & Prevent, Morgantown, WV 26505 USA
来源
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL | 1999年 / 60卷 / 05期
关键词
fit-test; N95; respirator; pass/fail criterion; total penetration;
D O I
10.1080/00028899908984481
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
During July 1995 the National Institute for Occupational Safety and Health (NIOSH) began to certify nine new classes of particulate respirators. To determine the level of performance of these respirators, NIOSH researchers conducted a study to (1) measure the simulated workplace performance of 21 N95 respirator models, (2) determine whether fit-testing affected the performance, and (3) investigate the effect of varying fit-test pass/fail criteria on respirator performance. The performance of each respirator model was measured by conducting 100 total penetration tests. The performance of each respirator model was then estimated by determining the 95th percentile of the total penetration through the respirator (i.e., 95% of wearers of that respirator can expect to have a total penetration value below the 95th percentile penetration value). The 95th percentile of total penetrations for each respirator without fit-testing ranged from 6 to 88%. The 95th percentile of total penetrations for all the respirators combined was 33%, which exceeds the amount of total penetration (10%) normally expected of a half-mask respirator. When a surrogate fit test (1% criterion) was applied to the data, the 95th percentile of total penetrations for each respirator decreased to 1 to 16%. The 95th percentile of total penetrations for all the respirators combined was only 4%. Therefore, fit-testing of N95 respirators is necessary to ensure that the user receives the expected level of protection. The study also found that respirator performance was dependent on the value of the pass/fail criterion used in the surrogate fit-test.
引用
收藏
页码:618 / 624
页数:7
相关论文
共 13 条
  • [1] *AM IND HYG ASS RE, 1985, AM IND HYG ASSOC J, V46, pB22
  • [2] *ANSI, 1992, Z28821992 ANSI
  • [3] *COD FED REG, 1991, RESP PROT DEV TESTS
  • [4] Comparison of six respirator fit test methods with an actual measurement of exposure in a simulated health care environment: Part II - Method comparison testing
    Coffey, CC
    Campbell, DL
    Myers, WR
    Zhuang, ZQ
    [J]. AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1998, 59 (12): : 862 - 870
  • [5] COLTON CE, 1991, RESP PROTECTION MANU, P81
  • [6] *FED REG, 1995, RESP PROT DEV FIN RU, V60, P30336
  • [7] *FED REG, 1998, RESP PROT FIN RUL, V63, P1273
  • [8] ASSIGNED PROTECTION FACTORS FOR 2 RESPIRATOR TYPES BASED UPON WORKPLACE PERFORMANCE TESTING
    LENHART, SW
    CAMPBELL, DL
    [J]. ANNALS OF OCCUPATIONAL HYGIENE, 1984, 28 (02) : 173 - 182
  • [9] *LOS AL SCI LAB, 1974, LA5488
  • [10] MULLINS HE, 1995, AM IND HYG ASSOC J, V56, P1068