An amplified graphene oxide-based fluorescence aptasensor based on target-triggered aptamer hairpin switch and strand-displacement polymerization recycling for bioassays

被引:45
|
作者
Hu, Kun [1 ]
Liu, Jinwen [1 ]
Chen, Jia [1 ]
Huang, Yong [1 ]
Zhao, Shulin [1 ]
Tian, Jianniao [1 ]
Zhang, Guohai [1 ]
机构
[1] Guangxi Normal Univ, Coll Chem & Chem Engn, Minist Educ, Key Lab Chem & Mol Engn Med Resources, Guilin 541004, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
Aptamer; Graphene oxide; Strand-displacement polymerization; Amplified fluorescence assay; Interferon-gamma; HIGHLY SENSITIVE DETECTION; PROTEIN-DETECTION; NUCLEIC-ACID; RESONANCE; DNA; ASSAY; IONS; NANOPARTICLES; DNAZYME;
D O I
10.1016/j.bios.2012.11.025
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An amplified graphene oxide (GO) based fluorescence aptasensor based on target-triggered aptamer hairpin switch and strand-displacement polymerization recycling is developed for bioassays. The dye-labeled single-strand DNA (aptamer hairpin) was adsorbed on the surface of GO, which result in the fluorescence quenching of dye, and exhibiting minimal background fluorescence. Upon the target, primer and polymerase, the stem of the aptamer hairpin was opened, and binds with the primer to triggers the circular target strand-displacement polymerization reaction, which produces huge amounts of duplex helixes DNA and lead to strong fluorescence emission due to shielding of nucelobases within its double-helix structure. During the polymerization reaction, the primer was extended, and target was displaced. And the displaced target recognizes and hybridizes with another hairpin probe, triggering the next round of polymerization reaction, and the circle process induces fluorescence signal amplification for the detection of analyte. To test the feasibility of the aptasensor systems, interferon-gamma (IFN-gamma) was employed as a model analyte. A detection limit as low as 1.5 fM is obtained based on the GO aptasensor with a linear range of three orders of magnitude. The present method was successfully applied for the detection of IFN-gamma in human plasma. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:598 / 602
页数:5
相关论文
共 25 条
  • [11] Fluorometric determination of agrA gene transcription in methicillin-resistant Staphylococcus aureus with a graphene oxide-based assay using strand-displacement polymerization recycling and hybridization chain reaction
    Ning, Yi
    Chen, Shanquan
    Hu, Jue
    Li, Ling
    Chen, Lijuan
    Lu, Fangguo
    MICROCHIMICA ACTA, 2020, 187 (07)
  • [12] A graphene oxide-based strand displacement amplification platform for ricin detection using aptamer as recognition element
    Li, Chun Hong
    Xiao, Xue
    Tao, Jing
    Wang, Dong Mei
    Huang, Cheng Zhi
    Zhen, Shu Jun
    BIOSENSORS & BIOELECTRONICS, 2017, 91 : 149 - 154
  • [13] A novel label-free fluorescence aptamer-based sensor method for cocaine detection based on isothermal circular strand-displacement amplification and graphene oxide absorption
    Qiu, Li
    Zhou, Hui
    Zhu, Wenping
    Qiu, Liping
    Jiang, Jianhui
    Shen, Guoli
    Yu, Ruqin
    NEW JOURNAL OF CHEMISTRY, 2013, 37 (12) : 3998 - 4003
  • [14] Highly Sensitive Multiple microRNA Detection Based on Fluorescence Quenching of Graphene Oxide and Isothermal Strand-Displacement Polymerase Reaction
    Dong, Haifeng
    Zhang, Jing
    Ju, Huangxian
    Lu, Huiting
    Wang, Shiyan
    Jin, Shi
    Hao, Kaihong
    Du, Hongwu
    Zhang, Xueji
    ANALYTICAL CHEMISTRY, 2012, 84 (10) : 4587 - 4593
  • [15] Graphene oxide-based fluorometric determination of methicillin-resistant Staphylococcus aureus by using target-triggered chain reaction and deoxyribonuclease-assisted recycling
    Yi Ning
    Li Zou
    Qiang Gao
    Jue Hu
    Fangguo Lu
    Microchimica Acta, 2018, 185
  • [16] Graphene oxide-based fluorometric determination of methicillin-resistant Staphylococcus aureus by using target-triggered chain reaction and deoxyribonuclease-assisted recycling
    Ning, Yi
    Zou, Li
    Gao, Qiang
    Hu, Jue
    Lu, Fangguo
    MICROCHIMICA ACTA, 2018, 185 (03)
  • [17] A label-free and enzyme-free fluorescent aptasensor for amplified detection of kanamycin in milk sample based on target-triggered catalytic hairpin assembly
    Cui, Wanling
    Hu, Guodong
    Lv, Enguang
    Li, Chonghui
    Wang, Zhenxing
    Li, Qiang
    Qian, Zhaohong
    Wang, Jihua
    Xu, Shicai
    Wang, Rui
    FOOD CONTROL, 2022, 133
  • [18] The systemic characterization of aptamer cocktail for bacterial detection studied by graphene oxide-based fluorescence resonance energy transfer aptasensor
    Li, Baichang
    Feng, Dongwei
    Miao, Yunfei
    Liang, Xuewang
    Gu, Le
    Lan, Hongying
    Gao, Shimeng
    Zhang, Yaxi
    Deng, Yulin
    Geng, Lina
    JOURNAL OF MOLECULAR RECOGNITION, 2021, 34 (12)
  • [19] An immobilization-free electrochemical aptamer-based assay for zearalenone based on target-triggered dissociation of DNA from polydopamine nanospheres with strand displacement amplification
    Zhu, Xi
    Yang, Caiping
    Quan, Wanqian
    Yang, Guidi
    Guo, Longhua
    Xu, Huifeng
    ANALYTICAL METHODS, 2023, 15 (07) : 987 - 992
  • [20] Homogeneous Electrochemical Method for Ochratoxin A Determination Based on Target Triggered Aptamer Hairpin Switch and Exonuclease III-Assisted Recycling Amplification
    Liu, Chang
    Guo, Yajing
    Luo, Fang
    Rao, Pingfan
    Fu, Caili
    Wang, Shaoyun