What Are the Quality of Life-Related Benefits and Losses Associated with Real-Time Continuous Glucose Monitoring? A Survey of Current Users

被引:73
作者
Polonsky, William H. [1 ,2 ]
Hessler, Danielle [3 ]
机构
[1] Univ Calif San Diego, San Diego, CA 92103 USA
[2] Behav Diabet Inst, San Diego, CA USA
[3] Univ Calif San Francisco, San Francisco, CA 94143 USA
关键词
SUBCUTANEOUS INSULIN INFUSION; MULTIPLE DAILY INJECTIONS; SATISFACTION; ACCURACY; ADULTS; CGM;
D O I
10.1089/dia.2012.0298
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: How does real-time (RT) continuous glucose monitoring (CGM) affect quality of life (QOL)? We explored the types and frequencies of diabetes-specific QOL changes resulting from RT-CGM as reported by current users and investigated what patient-reported factors predict these changes. Subjects and Methods: Current RT-CGM users (n = 877) completed an online questionnaire investigating perceived QOL benefits/losses since RT-CGM initiation and RT-CGM attitudes and behavior. Exploratory factor analysis (EFA) examined the 16 QOL benefit/loss items to identify underlying factors. Regression analyses examined associations between demographics and RT-CGM attitudes and behavior with the QOL factors emerging from the EFA. Results: Three major QOL factors emerged: Perceived Control over Diabetes, Hypoglycemic Safety, and Interpersonal Support. QOL improvement was common for Perceived Control over Diabetes and Hypoglycemic Safety (86% and 85% of respondents, respectively), although less common for Interpersonal Support (37%). Consistent independent predictors of perceived benefits were greater confidence in using RT-CGM data (P < 0.001), satisfaction with device accuracy (P <= 0.05) and usability (P < 0.01), older age (P < 0.01), more frequent receiver screen views (P < 0.05), and use of multiple daily injections (Hypoglycemic Safety and Interpersonal Support, P <= 0.05). Conclusions: Diabetes-specific QOL benefits resulting from RT-CGM were common. Major predictors of QOL benefits were satisfaction with device accuracy and usability and trust in one's ability to use RT-CGM data, suggesting that "perceived efficacy," for both device and self, are key QOL determinants. Psychoeducational strategies to boost confidence in using RT-CGM data and provide reasonable device expectations might enhance QOL benefits.
引用
收藏
页码:295 / 301
页数:7
相关论文
共 19 条
[1]   Effect of Continuous Glucose Monitoring on Hypoglycemia in Type 1 Diabetes [J].
Battelino, Tadej ;
Phillip, Moshe ;
Bratina, Natasa ;
Nimri, Revital ;
Oskarsson, Per ;
Bolinder, Jan .
DIABETES CARE, 2011, 34 (04) :795-800
[2]   The Effect of Continuous Glucose Monitoring in Well-Controlled Type 1 Diabetes [J].
Beck, Roy W. .
DIABETES CARE, 2009, 32 (08) :1378-1383
[3]   Use of Continuous Glucose Monitoring in Subjects With Type 1 Diabetes on Multiple Daily Injections Versus Continuous Subcutaneous Insulin Infusion Therapy A prospective 6-month study [J].
Garg, Satish K. ;
Voelmle, Mary K. ;
Beatson, Christie R. ;
Miller, Hayley A. ;
Crew, Lauren B. ;
Freson, Brandon J. ;
Hazenfield, Rachel M. .
DIABETES CARE, 2011, 34 (03) :574-579
[4]   Comparison of Accuracy and Safety of the SEVEN and the Navigator Continuous Glucose Monitoring Systems [J].
Garg, Satish K. ;
Smith, James ;
Beatson, Christie ;
Lopez-Baca, Benita ;
Voelmle, Mary ;
Gottlieb, Peter A. .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (02) :65-72
[5]   Psychometric Properties of the Hypoglycemia Fear Survey-II for Adults With Type 1 Diabetes [J].
Gonder-Frederick, Linda A. ;
Schmidt, Karen M. ;
Vajda, Karen A. ;
Greear, Megan L. ;
Singh, Harsimran ;
Shepard, Jaclyn A. ;
Cox, Daniel J. .
DIABETES CARE, 2011, 34 (04) :801-806
[6]   Determining Clinical and Psychological Benefits and Barriers with Continuous Glucose Monitoring Therapy [J].
Halford, Jean ;
Harris, Claudia .
DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (03) :201-205
[7]   Validation of Measures of Satisfaction with and Impact of Continuous and Conventional Glucose Monitoring [J].
Hirsch, Irl B. ;
Gilliam, Lisa K. ;
Fitzpatrick, Kathy ;
Khakpour, Dori ;
Weinzimer, Stuart A. ;
Tamborlane, William V. ;
Ives, Brett ;
Bosson-Heenan, Joan ;
Wolpert, Howard ;
Shetty, Greeshma ;
Atakov-Castillo, Astrid ;
Giusti, Judith ;
O'Donnell, Stacey ;
Ghiloni, Suzanne ;
Bode, Bruce W. ;
O'Neil, Kelli ;
Tolbert, Lisa ;
Wysocki, Tim ;
Fox, Larry A. ;
Mauras, Nelly ;
Englert, Kimberly ;
Permuy, Joe ;
Buckingham, Bruce ;
Wilson, Darrell M. ;
Block, Jennifer ;
Benassi, Kari ;
Tsalikian, Eva ;
Tansey, Michael ;
Kucera, Debra ;
Coffey, Julie ;
Cabbage, Joanne ;
Laffel, Lori ;
Milaszewski, Kerry ;
Pratt, Katherine ;
Bismuth, Elise ;
Keady, Joyce ;
Lawlor, Margie ;
Chase, H. Peter ;
Fiallo-Scharer, Rosanna ;
Wadwa, Paul ;
Messer, Laurel ;
Gage, Victoria ;
Burdick, Patricia ;
Lawrence, Jean M. ;
Clemons, Robert ;
Maeva, Michelle ;
Sattler, Bonnie ;
Beck, Roy W. ;
Ruedy, Katrina J. ;
Kollman, Craig .
DIABETES TECHNOLOGY & THERAPEUTICS, 2010, 12 (09) :679-684
[8]   Continuous glucose monitoring systems for type 1 diabetes mellitus [J].
Langendam, Miranda W. ;
Luijf, Yoeri M. ;
Hooft, Lotty ;
DeVries, J. Hans ;
Mudde, Aart H. ;
Scholten, Rob J. P. M. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (01)
[9]   Evaluating the Accuracy, Reliability, and Clinical Applicability of Continuous Glucose Monitoring (CGM): Is CGM Ready for Real Time? [J].
Mazze, Roger S. ;
Strock, Ellie ;
Borgman, Sarah ;
Wesley, David ;
Stout, Philip ;
Racchini, Joel .
DIABETES TECHNOLOGY & THERAPEUTICS, 2009, 11 (01) :11-18
[10]   Quality of life and treatment satisfaction in adults with Type 1 diabetes: a comparison between continuous subcutaneous insulin infusion and multiple daily injections [J].
Nicolucci, A. ;
Maione, A. ;
Franciosi, M. ;
Amoretti, R. ;
Busetto, E. ;
Capani, F. ;
Bruttomesso, D. ;
Di Bartolo, P. ;
Girelli, A. ;
Leonetti, F. ;
Morviducci, L. ;
Ponzi, P. ;
Vitacolonna, E. .
DIABETIC MEDICINE, 2008, 25 (02) :213-220