Surface characterization and bonding properties of milled polyetheretherketone dental posts

被引:31
作者
Benli, Merve [1 ]
Gumus, Beril Eker [2 ,3 ]
Kahraman, Yusuf [2 ,3 ]
Huck, Olivier [4 ,5 ,6 ]
Ozcan, Mutlu [7 ]
机构
[1] Istanbul Univ, Fac Dent, Dept Prosthodont, Istanbul, Turkey
[2] Yildiz Tech Univ, Sci & Technol Applicat, Istanbul, Turkey
[3] Yildiz Tech Univ, Res Ctr, Istanbul, Turkey
[4] Federat Med Translat Strasbourg FMTS, Fac Med, UMR Osteoarticular & Dent Regenerat Nanomed 1260, INSERM, Strasbourg, France
[5] Hop Univ Strasbourg, Pole Med & Chirurg Bucco Dent, Strasbourg, France
[6] Univ Strasbourg, Fac Chirurg Dent, Strasbourg, France
[7] Univ Zurich, Ctr Dent & Oral Med, Dent Mat Unit, Clin Fixed & Removable Prosthodont & Dent Mat Sci, Zurich, Switzerland
关键词
Polyetheretherketone; Dental post; Tensile bond; Surface roughness; Post failure; ENDODONTICALLY TREATED TEETH; GLASS-FIBER POSTS; OF-THE-LITERATURE; BIOMECHANICAL CONSIDERATIONS; MECHANICAL-PROPERTIES; LUTING AGENTS; ROOT CANALS; STRENGTH; PEEK; COMPOSITE;
D O I
10.1007/s10266-020-00484-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
PEEK has been used in many dental applications except intra-radicular post. The aim of this study is to test polyetheretherketone (PEEK) as a dental post material through tensile bond strength (TBS) and surface roughness (SR), and to compare it with glass-fiber and cast-metal posts. Thus, 60 human maxillary central incisors with a single root were endodontically treated and divided into three groups (n = 20) according to the type of post (Group P: PEEK, Group F: Glass-fiber, Group M: Cast-metal). Appropriate surface treatment was employed for each group and SR was determined by a three-dimensional non-contact profilometer before cementation. All posts were luted to the canal dentin using self-etch resin cement (Panavia F2.0). Pull-out test was performed on a universal testing machine at a speed of 0.5 mm/min crosshead speed until failure, and TBS were calculated. One-way ANOVA, Tukey's HSD, and Pearson chi-squared tests were performed for statistical analyses (alpha = 0.05). According to the results, group F demonstrated the highest SR (2.93 +/- 0.18 mu m) and lowest TBS values (10.05 +/- 0.53 MPa), while group P exhibited lowest SR (1.37 +/- 0.11 mu m) and highest TBS values (14.33 +/- 0.58 MPa) (p < 0.001). No significant differences in failure modes were identified among groups, mostly adhesive (p = 0.243). As conclusion, PEEK may be a reliable and contemporary option for dental post systems when used with appropriate surface treatment and luting agent. This high-performance polymer may be a novel candidate as a contemporary dental post system due to its superior mechanical, chemical, thermal, and esthetical properties with low risk of fracture.
引用
收藏
页码:596 / 606
页数:11
相关论文
共 74 条
[1]  
Ahmet SO, 2019, AM J DENT, V32, P113
[2]   EFFECT OF LUTING AGENTS ON THE TENSILE BOND STRENGTH OF GLASS FIBER POSTS: AN IN VITRO STUDY [J].
Aleisa, Khalil ;
Al-Dwairi, Ziad N. ;
Alghabban, Rawda ;
Goodacre, Charles J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (03) :216-222
[3]  
[Anonymous], 1997, 42871997 ISO
[4]   Effect of surface treatment on retention of glass-fiber endodontic posts [J].
Balbosh, A ;
Kern, M .
JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (03) :218-223
[5]   Load-bearing capacity of all-ceramic three-unit fixed partial dentures with different computer-aided design (CAD)/computer-aided manufacturing (CAM) fabricated framework materials [J].
Beuer, Florian ;
Steff, Bastian ;
Naumann, Michael ;
Sorensen, John A. .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2008, 116 (04) :381-386
[6]   Effect of casting technique on surface roughness and consequent mass loss after polishing of NiCr and CoCr base metal alloys: A comparative study with titanium [J].
Bezzon, OL ;
Pedrazzi, H ;
Zaniquelli, O ;
da Silva, TBC .
JOURNAL OF PROSTHETIC DENTISTRY, 2004, 92 (03) :274-277
[7]  
Bonfante Gerson, 2007, Braz. oral res., V21, P159
[8]   An In Vitro Evaluation of the Effect of Various Adhesives and Surface Treatments on Bond Strength of Resin Cement to Polyetheretherketone [J].
Caglar, Ipek ;
Ates, Sabit Melih ;
Duymus, Zeynep Yesil .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01) :E342-E349
[9]   Effects of different sulfuric acid etching concentrations on PEEK surface bonding to resin composite [J].
Chaijareenont, Pisaisit ;
Prakhamsai, Sasiprapha ;
Silthampitag, Patcharawan ;
Takahashi, Hidekazu ;
Arksornnukit, Mansuang .
DENTAL MATERIALS JOURNAL, 2018, 37 (03) :385-392
[10]   Mechanical properties of glass fiber-reinforced endodontic posts [J].
Cheleux, Nicolas ;
Sharrock, Patrick J. .
ACTA BIOMATERIALIA, 2009, 5 (08) :3224-3230