Application of Ultrasonic Guided Waves for Inspection of High Density Polyethylene Pipe Systems

被引:17
作者
Lowe, Premesh Shehan [1 ]
Lais, Habiba [2 ]
Paruchuri, Veena [3 ]
Gan, Tat-Hean [2 ]
机构
[1] Univ Sheffield, Nucl AMRC, Brunel Way, Rotherham S60 5WG, S Yorkshire, England
[2] Brunel Innovat Ctr, Granta Pk, Great Abington CB21 6AL, Cambs, England
[3] Univ Surrey, Stag Hill, Guildford GU2 7XH, Surrey, England
关键词
thermoplastic pipe; ultrasonic guided waves; inspection; array design; non-destructive testing; finite element analysis; industrialization; flexible macro-fiber composite transducer; MODE; PROPAGATION; TRANSDUCER;
D O I
10.3390/s20113184
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The structural integrity assessment of thermoplastic pipes has become an interesting area of research due to its elevated usage in the liquid/gas transportation industry. Ultrasonic guided wave testing has gained higher attention from industry for the inspection of elongated structures due to the reduced inspection time and cost associated with conventional non-destructive testing techniques, e.g., ultrasonic testing, radiography, and visual inspection. Current research addresses the inspection of thermoplastic pipes using ultrasonic guided waves as a low cost and permanently installed structural health-monitoring tool. Laboratory and numerical investigations were conducted to study the potential of using ultrasonic guided waves to assess the structural health of thermoplastic pipe structures in order to define optimum frequency range for inspection, array design, and length of inspection. In order to achieve a better surface contact, flexible Macro-Fiber Composite transducers were used in this investigation, and the Teletest((R)) Focus+ system was used as the pulser/receiver. Optimum frequency range of inspection was at 15-25 kHz due to the level of attenuation at higher frequencies and the larger dead zone at lower frequencies due to the pulse length. A minimum of 14 transducers around the circumference of a 3 inch pipe were required to suppress higher order flexural modes at 16 kHz. According to the studied condition, 1.84 m of inspection coverage could be achieved at a single direction for pulse-echo, which could be improved by using a higher number of transducers for excitation and using pitch-catch configuration.
引用
收藏
页码:1 / 15
页数:15
相关论文
共 23 条
  • [21] Wilcox PD, 2001, J INTEL MAT SYST STR, V12, P553, DOI [10.1177/10453890122145348, 10.1106/N9PB-Y62E-P0Y2-50QF]
  • [22] Evaluation of fatigue cracks using nonlinearities of acousto-ultrasonic waves acquired by an active sensor network
    Zhou, Chao
    Hong, Ming
    Su, Zhongqing
    Wang, Qiang
    Cheng, Li
    [J]. SMART MATERIALS AND STRUCTURES, 2013, 22 (01)
  • [23] Non-Destructive In-Situ Condition Assessment of Plastic Pipe Using Ultrasound
    Zhu, Juanjuan
    Collins, Richard P.
    Boxall, Joby B.
    Mills, Robin S.
    Dwyer-joyce, Rob
    [J]. COMPUTING AND CONTROL FOR THE WATER INDUSTRY (CCWI2015): SHARING THE BEST PRACTICE IN WATER MANAGEMENT, 2015, 119 : 148 - 157