Failed intubation has been a serious problem in obstetric anaesthesia in the UK. The current study was designed to assess the use of the 'ACCESS' simulator (Anaesthetic Computer-Controlled Emergency Situation Simulator) to evaluate our trainees' performance in an obstetric failed intubation setting. Using a scoring system based on our department's failed intubation drill in obstetrics, 13 junior anaesthetists were recruited for the study and all took part in the simulation exercise. Six weeks later they were all tutored as a group or individually on the important points raised from their first simulations. Two weeks after that, 12 of the candidates were re-tested, and 11 scored better than their first time. The results were confidential and the authors ensured all feedback was of a positive nature. The study shows that a simulator may be a useful tool for assessment of performance in a simulated emergency situation when combined with practice and formal teaching. (C) 2001 Harcourt Publishers Ltd.
引用
收藏
页码:273 / 277
页数:5
相关论文
共 11 条
[1]  
BYRNE AJ, 1994, ANAESTHESIA, V49, P376
[2]   DOES TRAINING ON AN ANESTHESIA SIMULATOR LEAD TO IMPROVEMENT IN PERFORMANCE [J].
CHOPRA, V ;
GESINK, BJ ;
DEJONG, J ;
BOVILL, JG ;
SPIERDIJK, J ;
BRAND, R .
BRITISH JOURNAL OF ANAESTHESIA, 1994, 73 (03) :293-297
[3]   A COMPREHENSIVE ANESTHESIA SIMULATION ENVIRONMENT - RECREATING THE OPERATING-ROOM FOR RESEARCH AND TRAINING [J].
GABA, DM ;
DEANDA, A .
ANESTHESIOLOGY, 1988, 69 (03) :387-394
[4]   Difficult and failed intubation in obstetrics [J].
Harmer, M .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 1997, 6 (01) :25-31
[5]   Airway obstruction with cricoid pressure [J].
Hartsilver, EL ;
Vanner, RG .
ANAESTHESIA, 2000, 55 (03) :208-211
[6]   General anesthesia for cesarean section: are we really prepared? [J].
Hawkins, JL ;
Gibbs, CP .
INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 1998, 7 (03) :145-146
[7]   Failed intubation revisited: 17-yr experience in a teaching maternity unit [J].
Hawthorne, L ;
Wilson, R ;
Lyons, G ;
Dresner, M .
BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 (05) :680-684
[8]   Training in obstetric general anaesthesia: a vanishing art? [J].
Johnson, RV ;
Lyons, GR ;
Wilson, RC ;
Robinson, APC .
ANAESTHESIA, 2000, 55 (02) :179-183
[9]  
*ROYAL COLL AN, 1994, SPEC TRAIN AN SUP AS
[10]   Use of a computerized ACLS simulator improves performance of ACLS guidelines [J].
Schwid, HA ;
Rooke, A ;
Ross, BK ;
Sivarajan, M .
ANESTHESIOLOGY, 1997, 87 (03) :A934-A934