Amperometric detection of hydrogen peroxide at nano-ruthenium oxide/riboflavin nanocomposite-modifled glassy carbon electrodes

被引:40
作者
Roushani, Mahmoud [1 ]
Karami, Elham [1 ]
Salimi, Abdollah [2 ]
Sahraei, Reza [1 ]
机构
[1] Ilam Univ, Dept Chem, Ilam, Iran
[2] Univ Kurdistan, Dept Chem, Sanandaj, Iran
关键词
Hydrogen peroxide; Nano-ruthenium oxide; RF; Chemical modified electrode; Electrocatalytic; HORSERADISH-PEROXIDASE; NANOPARTICLES; BIOSENSOR; REDUCTION; GRAPHENE; OXIDE; H2O2; GRAPHITE; PLATINUM; GLUCOSE;
D O I
10.1016/j.electacta.2013.09.069
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A simple and sensitive electrochemical sensor based on nano-ruthenium oxide/riboflavin modified glassy carbon (GC/RuOx/RF) electrode was constructed and utilized to determine H2O2. By immersing the GC/RuOx modified electrode into RF solution for a short period of time (5-70 s), a thin film of the proposed molecule was immobilized onto the electrode surface. The modified electrode showed stable and a well-defined redox couples at a wide pH range (1-10), with surface confined characteristics. Experimental results revealed that RF was adsorbed on the surface of RuOx nanoparticles (NPs) and in comparison to usual methods for the immobilization of RF, such as electropolymerization, the electrochemical reversibility and stability of this modified electrode has been improved. The heterogeneous electron transfer rate constant (k(s)) and the surface coverage of immobilized RF on the GC/RuOx electrode was obtained as 16.8 s(-1) and 2.2 x 10(-11) mol cm(-2), respectively. The electrocatalytic activity of the modified electrode toward hydrogen peroxide reduction was investigated and it was found that the GC/RuOx/RF electrode illustrates electrocatalytic activity toward H2O2 reduction at reduced overpotential. The catalytic rate constant (k(cat)) of the modified electrode toward H2O2 is 9.1 x 10(3) M-1 s(-1). This biosensor shows excellent sensitivity toward H2O2 in buffer solution (pH 7) with a wide linear range from 0.15 mu M to 3 mM. The detection limit and sensitivity are 150 nM and 35 nA mu M-1 respectively. Furthermore, the fabricated H2O2 chemical sensor exhibited excellent stability, remarkable catalytic activity and reproducibility. Published by Elsevier Ltd.
引用
收藏
页码:134 / 140
页数:7
相关论文
共 38 条
[1]  
ANDRIEUX CP, 1978, J ELECTROANAL CHEM, V93, P163, DOI 10.1016/S0022-0728(78)80230-7
[2]   Simultaneous determination of chlorine and oxygen evolving at RuO2/Ti and RuO2-TiO2/Ti anodes by differential electrochemical mass spectroscopy [J].
Arikawa, T ;
Murakami, Y ;
Takasu, Y .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1998, 28 (05) :511-516
[3]   Electrochemical sensing of NADH based on Meldola Blue immobilized silver nanoparticle-conducting polymer electrode [J].
Balamurugan, A. ;
Ho, Kun-Cheng ;
Chen, Shen-Ming ;
Huang, Tzu-Yen .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2010, 362 (1-3) :1-7
[4]   ELECTROOXIDATION OF CO AND METHANOL ON GRAPHITE-BASED PLATINUM-ELECTRODES COMBINED WITH OXIDE-SUPPORTED ULTRAFINE GOLD PARTICLES [J].
BISWAS, PC ;
NODASAKA, Y ;
ENYO, M ;
HARUTA, M .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 381 (1-2) :167-177
[5]  
Breyer B., 1960, Journal of Electroanalytical Chemistry, V1, P453, DOI 10.1016/0022-0728(60)85293-X
[6]   Dithiobissuccinimidyl propionate as an anchor for assembling peroxidases at electrodes surfaces and its application in a H2O2 biosensor [J].
Darder, M ;
Takada, K ;
Pariente, F ;
Lorenzo, E ;
Abruña, HD .
ANALYTICAL CHEMISTRY, 1999, 71 (24) :5530-5537
[7]  
Friedrich W., 1988, VITAMINS, P404
[8]   CYCLIC VOLTAMMETRY OF FAD ADSORBED ON GRAPHITE, GLASSY-CARBON, PLATINUM AND GOLD ELECTRODES [J].
GORTON, L ;
JOHANSSON, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1980, 113 (01) :151-158
[9]  
Hamid R., 2011, SENSOR ACTUAT B-CHEM, V160, P1450
[10]   UNUSUAL ADSORPTION EFFECTS IN ELECTROCHEMICAL REDUCTION OF FLAVIN MONONUCLEOTIDE AT MERCURY ELECTRODES [J].
HARTLEY, AM ;
WILSON, GS .
ANALYTICAL CHEMISTRY, 1966, 38 (06) :681-&