Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography

被引:43
作者
Chansangpetch, Sunee [1 ,2 ,3 ]
Nguyen, Anwell [1 ]
Mora, Marta [1 ]
Badr, Mai [1 ]
He, Mingguang [4 ,5 ]
Porco, Travis C. [1 ]
Lin, Shan C. [1 ]
机构
[1] Univ Calif San Francisco, Dept Ophthalmol, 10 Koret Way, San Francisco, CA 94143 USA
[2] Chulalongkorn Univ, Dept Ophthalmol, Bangkok, Thailand
[3] King Chulalongkorn Mem Hosp, Thai Red Cross Soc, Bangkok, Thailand
[4] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Guangdong, Peoples R China
[5] Univ Melbourne, Royal Victorian Eye & Ear Hosp, Ctr Eye Res Australia, East Melbourne, Australia
基金
美国国家卫生研究院;
关键词
CASIA2; Visante OCT; anterior segment optical coherence tomography; swept-source Fourier-domain anterior segment optical coherence tomography; time-domain anterior segment optical coherence tomography; CHAMBER ANGLE MEASUREMENTS; NARROW ANGLES; GLAUCOMA; REPRODUCIBILITY; VISANTE; EYES; THICKNESS; BIOMETRY; DEVICES; CLOSURE;
D O I
10.1167/iovs.17-23574
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). METHODS. Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty-degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. RESULTS. ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771-0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [ CI]: 1.953.18), temporal ARA750 (slope 2.57, 95% CI: 2.04-3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12-1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (-0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. CONCLUSIONS. Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably.
引用
收藏
页码:1554 / 1561
页数:8
相关论文
共 34 条
[1]   Comparison of Anterior Segment Optical Tomography Parameters Measured Using a Semi-Automatic Software to Standard Clinical Instruments [J].
Ang, Marcus ;
Chong, Wesley ;
Huang, Huiqi ;
Tay, Wan Ting ;
Wong, Tien Yin ;
He, Ming-Guang ;
Aung, Tin ;
Mehta, Jodhbir S. .
PLOS ONE, 2013, 8 (06)
[2]   Anterior Segment Biometry Using Spectral-Domain Optical Coherence Tomography [J].
Aptel, Florent ;
Chiquet, Christophe ;
Gimbert, Aurelie ;
Romanet, Jean-Paul ;
Thuret, Gilles ;
Gain, Philippe ;
Campolmi, Nelly .
JOURNAL OF REFRACTIVE SURGERY, 2014, 30 (05) :354-+
[3]   Quantitative analysis of anterior segment optical coherence tomography images: the Zhongshan Angle Assessment Program [J].
Console, J. W. ;
Sakata, L. M. ;
Aung, T. ;
Friedman, D. S. ;
He, M. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2008, 92 (12) :1612-1616
[4]   Computer-animated model of accommodation and theory of reciprocal zonular action [J].
Goldberg, Daniel B. .
CLINICAL OPHTHALMOLOGY, 2011, 5 :1559-1566
[5]  
Ha Ahnul, 2016, Korean J Ophthalmol, V30, P140, DOI 10.3341/kjo.2016.30.2.140
[6]   Spectral- and time-domain optical coherence tomography measurements of macular thickness in normal eyes and in eyes with diabetic macular edema [J].
Ibrahim, M. A. ;
Sepah, Y. J. ;
Symons, R. C. A. ;
Channa, R. ;
Hatef, E. ;
Khwaja, A. ;
Bittencourt, M. ;
Heo, J. ;
Do, D. V. ;
Nguyen, Q. D. .
EYE, 2012, 26 (03) :454-462
[7]   A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research [J].
Koo, Terry K. ;
Li, Mae Y. .
JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) :155-163
[8]   Screening of narrow angles in the Singapore population: Evaluation of new noncontact screening methods [J].
Lavanya, Raghavan ;
Foster, Paul J. ;
Sakata, Lisandro M. ;
Friedman, David S. ;
Kashiwagi, Kenji ;
Wong, Tien-Yin ;
Aung, Han T. ;
Alfred, Tamuno ;
Gao, Hong ;
Ee, Adrian G. ;
Seah, Steve K. ;
Aung, Tin .
OPHTHALMOLOGY, 2008, 115 (10) :1720-1727
[9]   Anterior chamber angle measurement with anterior segment optical coherence tomography: A comparison between slit lamp OCT and Visante OCT [J].
Leung, Christopher Kai-Shun ;
Li, Haitao ;
Weinreb, Robert Neal ;
Liu, Jing ;
Cheung, Carol Yim Lui ;
Lai, Ricky Yiu Kwong ;
Pang, Chi Pui ;
Lam, Dennis Shun Chiu .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2008, 49 (08) :3469-3474
[10]   Comparative study of central corneal thickness measurement with slit-lamp optical coherence tomography and visante optical coherence tomography [J].
Li, Haitao ;
Leung, Christopher Kai Shun ;
Wong, Lee ;
Cheung, Carol Yim Lui ;
Pang, Chi Pui ;
Weinreb, Robert Neal ;
Lam, Dennis Shun Chiu .
OPHTHALMOLOGY, 2008, 115 (05) :796-801