The role of99mTc-MIBI SPECT/CT in patients with secondary hyperparathyroidism: comparison with99mTc-MIBI planar scintigraphy and ultrasonography

被引:18
作者
Jiang, Shu-Qin [1 ]
Yang, Ting [1 ]
Zou, Qiong [1 ]
Xu, Lei [1 ]
Ye, Ting [1 ]
Kang, Yin-Qian [1 ]
Li, Wan-Ru [1 ]
Jiao, Ju [1 ]
Zhang, Yong [1 ]
机构
[1] Sun Yat Sen Univ, Affiliated Hosp 3, Dept Nucl Med, 600 Tianhe Rd,Tianhe St, Guangzhou 510630, Peoples R China
关键词
(99m)tc-MIBI SPECT; CT; Secondary hyperparathyroidism; Sensitivity; TC-99M-SESTAMIBI SCINTIGRAPHY; COMPUTED-TOMOGRAPHY; TC-99M-MIBI; PARATHYROIDECTOMY; LOCALIZATION; ULTRASOUND; NECK;
D O I
10.1186/s12880-020-00517-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background This study aimed to compare the sensitivity of(99m)Tc-MIBI SPECT/CT,Tc-99m-MIBI planar scintigraphy and ultrasonography (US) in patients with secondary hyperparathyroidism (SHPT), and to explore the factors that affect the sensitivity of(99m)Tc-MIBI SPECT/CT. Methods In this retrospective study, forty-six patients with SHPT who underwent(99m)Tc-MIBI planar scintigraphy,Tc-99m-MIBI SPECT/CT and US were enrolled. They underwent surgery within 1 month. We compared the sensitivity of the different imaging methods based on the lesions according to the pathological results. The parathyroid lesions on(99m)Tc-MIBI SPECT/CT images were divided into missed diagnosis group (MDG) and non-missed diagnosis group (NMDG). We compared the lesion to background ratio (LBR), maximum diameter, volume, the mean CT Hounsfield unit values (CTmean) and location of lesions between MDG and NMDG. Results The sensitivity of(99m)Tc-MIBI SPECT/CT,Tc-99m-MIBI planar scintigraphy and US were 70.30% versus 48.48% versus 61.82%, respectively. The sensitivity of(99m)Tc-MIBI SPECT/CT combined US was 79.39%, which was higher than(99m)Tc-MIBI SPECT/CT with significant difference (P = 0.000). On(99m)Tc-MIBI SPECT/CT images, the LBR, maximum diameter and volume of lesions in MDG was smaller than those in NMDG with significant difference (P < 0.001). The average LBR, maximum diameter and volume of lesions in MDG and NMDG were 3.42 +/- 1.28, 9.32 +/- 2.69 mm, 208.51 +/- 163.22 mm(3)versus 6.75 +/- 5.08, 15.03 +/- 4.94 mm and 863.85 +/- 1216.0 mm(3), respectively. Conclusions Tc-99m-MIBI SPECT/CT exhibited the highest sensitivity among the three methods. When(99m)Tc-MIBI SPECT/CT combined with US, the sensitivity can be further improved. Lesions with lower MIBI uptake and smaller lesions on(99m)Tc-MIBI SPECT/CT images were easily missed.
引用
收藏
页数:7
相关论文
共 26 条
[1]   Contrast-enhanced computed tomography does not improve the diagnostic value of parathyroid dual-phase MIBI SPECT/CT [J].
Andersen, Trine B. ;
Aleksyniene, Ramune ;
Boldsen, Soren K. ;
Gade, Michael ;
Bertelsen, Henrik ;
Petersen, Lars J. .
NUCLEAR MEDICINE COMMUNICATIONS, 2018, 39 (05) :435-440
[2]   Hyperparathyroidism [J].
Bilezikian, John P. ;
Bandeira, Leonardo ;
Khan, Aliya ;
Cusano, Natalie E. .
LANCET, 2018, 391 (10116) :168-178
[3]   Effect of Etelcalcetide vs Cinacalcet on Serum Parathyroid Hormone in Patients Receiving Hemodialysis With Secondary Hyperparathyroidism A Randomized Clinical Trial [J].
Block, Geoffrey A. ;
Bushinsky, David A. ;
Cheng, Sunfa ;
Cunningham, John ;
Dehmel, Bastian ;
Drueke, Tilman B. ;
Ketteler, Markus ;
Kewalramani, Reshma ;
Martin, Kevin J. ;
Moe, Sharon M. ;
Patel, Uptal D. ;
Silver, Justin ;
Sun, Yan ;
Wang, Hao ;
Chertow, Glenn M. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2017, 317 (02) :156-164
[4]   Comparison of ultrasonographic characteristics of the thyroid gland in healthy small-, medium-, and large-breed dogs [J].
Brömel, C ;
Pollard, RE ;
Kass, PH ;
Samii, VF ;
Davidson, AP ;
Nelson, RW .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2006, 67 (01) :70-77
[5]   99mTc-MIBI pinhole SPECT in primary hyperparathyroidism:: comparison with conventional SPECT, planar scintigraphy and ultrasonography [J].
Carlier, Thomas ;
Oudoux, Aurore ;
Mirallie, Eric ;
Seret, Alain ;
Daumy, Isabelle ;
Leux, Christophe ;
Bodet-Milin, Caroline ;
Kraeber-Bodere, Francoise ;
Ansquer, Catherine .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (03) :637-643
[6]   2009 EANM parathyroid guidelines [J].
Hindie, Elif ;
Ugur, Oemer ;
Fuster, David ;
O'Doherty, Michael ;
Grassetto, Gaia ;
Urena, Pablo ;
Kettle, Andrew ;
Gulec, Seza A. ;
Pons, Francesca ;
Rubello, Domenico .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 (07) :1201-1216
[7]   Clinical Value of Tc99m-MIBI SPECT/CT Versus 4D-CT or US in Management of Patients With Hyperparathyroidism [J].
Kedarisetty, Suraj ;
Fundakowski, Christopher ;
Ramakrishnan, Karthika ;
Dadparvar, Simin .
ENT-EAR NOSE & THROAT JOURNAL, 2019, 98 (03) :149-157
[8]  
Kobylecka M, 2017, J ULTRASON, V17, P17, DOI 10.15557/JoU.2017.0002
[9]   A Prospective Comparative Study of Parathyroid Dual-Phase Scintigraphy, Dual-Isotope Subtraction Scintigraphy, 4D-CT, and Ultrasonography in Primary Hyperparathyroidism [J].
Krakauer, Martin ;
Wieslander, Bente ;
Myschetzky, Peter S. ;
Lundstrom, Anke ;
Bacher, Theis ;
Sorensen, Christian H. ;
Trolle, Waldemar ;
Nygaard, Birte ;
Bennedbaek, Finn N. .
CLINICAL NUCLEAR MEDICINE, 2016, 41 (02) :93-100
[10]   Parathyroidectomy in the Management of Secondary Hyperparathyroidism [J].
Lau, Wei Ling ;
Obi, Yoshitsugu ;
Kalantar-Zadeh, Kamyar .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2018, 13 (06) :952-961