Noncontrast-enhanced renal angiography using multiple inversion recovery and alternating TR balanced steady-state free precession

被引:2
作者
Dong, Hattie Z. [1 ]
Worters, Pauline W. [2 ]
Wu, Holden H. [1 ,3 ]
Ingle, R. Reeve [1 ]
Vasanawala, Shreyas S. [2 ]
Nishimura, Dwight G. [1 ]
机构
[1] Stanford Univ, Magnet Resonance Syst Res Lab, Dept Elect Engn, Stanford, CA 94305 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[3] Stanford Univ, Div Cardiovasc Med, Stanford, CA 94305 USA
关键词
angiography; noncontrast-enhanced angiography; SSFPangiography; multiple inversion recovery; projective imaging; MR-ANGIOGRAPHY; BREATH-HOLD; RF PULSES; ARTERIES; SEQUENCES; DESIGN; SSFP;
D O I
10.1002/mrm.24480
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Noncontrast-enhanced renal angiography techniques based on balanced steady-state free precession avoid external contrast agents, take advantage of high inherent blood signal from the T-2/T-1 contrast mechanism, and have short steady-state free precession acquisition times. However, background suppression is limited; inflow times are inflexible; labeling region is difficult to define when tagging arterial flow; and scan times are long. To overcome these limitations, we propose the use of multiple inversion recovery preparatory pulses combined with alternating pulse repetition time balanced steady-state free precession to produce renal angiograms. Multiple inversion recovery uses selective spatial saturation followed by four nonselective inversion recovery pulses to concurrently null a wide range of background T-1 species while allowing for adjustable inflow times; alternating pulse repetition time steady-state free precession maintains vessel contrast and provides added fat suppression. The high level of suppression enables imaging in three-dimensional as well as projective two-dimensional formats, the latter of which has a scan time as short as one heartbeat. In vivo studies at 1.5 T demonstrate the superior vessel contrast of this technique. Magn Reson Med 70:527-536, 2013. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:527 / 536
页数:10
相关论文
共 50 条
  • [41] Fluoroscopic contrast-enhanced MR angiography with a magnetization-prepared steady-state free precession technique in peripheral arterial occlusive disease
    Huegli, RW
    Aschwanden, M
    Scheffler, K
    Bilecen, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (01) : 242 - 247
  • [42] Fat-suppressed steady-state free precession imaging using phase detection
    Hargreaves, BA
    Vasanawala, SS
    Nayak, KS
    Hu, BS
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2003, 50 (01) : 210 - 213
  • [43] Assessment of Magnetization Transfer Effects in Myocardial Tissue Using Balanced Steady-State Free Precession (bSSFP) Cine MRI
    Weber, Oliver M.
    Speier, Peter
    Scheffler, Klaus
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (03) : 699 - 705
  • [44] Highly Accelerated Breath-Hold Noncontrast Electrocardiographically- and Pulse-Gated Balanced Steady-State Free Precession Magnetic Resonance Angiography of the Thoracic Aorta: Comparison With Electrocardiographically-Gated Computed Tomographic Angiography
    Lim, Ruth P.
    Singh, Susan G.
    Hornsey, Emma
    Kearney, Leighton
    Churilov, Leonid
    Storey, Pippa
    Begbie, Mark
    Shoobridge, Jennifer
    Xu, Jian
    Rayner, Melanie
    Matalanis, George
    Smith, Gerard
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2019, 43 (02) : 323 - 332
  • [45] Improved In-Stent Lumen Visualization using Intravascular MRI and a Balanced Steady-State Free-Precession Sequence
    Gilbert, Guillaume
    Soulez, Gilles
    Beaudoin, Gilles
    ACADEMIC RADIOLOGY, 2009, 16 (12) : 1466 - 1474
  • [46] Arterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling
    Han, Paul Kyu
    Marin, Thibault
    Zhuo, Yue
    Ouyang, Jinsong
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 126 - 132
  • [47] Intrascanner and Interscanner Variability of Magnetization Transfer-Sensitized Balanced Steady-State Free Precession Imaging
    Gloor, M.
    Scheffler, K.
    Bieri, O.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (04) : 1113 - 1118
  • [48] Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP): repeatability and comparison of different tagging location
    Yuyang Zhang
    Zhen Xing
    Ying Liu
    Dejun She
    Zheng Zeng
    Dairong Cao
    Abdominal Imaging, 2014, 39 : 1000 - 1008
  • [49] Rapid anatomical imaging of the neonatal brain using T2-prepared 3D balanced steady-state free precession
    Park, Jinho
    Jang, MinJung
    Heier, Linda
    Limperopoulos, Catherine
    Zun, Zungho
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (04) : 1456 - +
  • [50] Nonenhanced renal MR angiography using steady-state free precession (SSFP) and time-spatial labeling inversion pulse (Time-SLIP): repeatability and comparison of different tagging location
    Zhang, Yuyang
    Xing, Zhen
    Liu, Ying
    She, Dejun
    Zeng, Zheng
    Cao, Dairong
    ABDOMINAL IMAGING, 2014, 39 (05): : 1000 - 1008