Clinical Study of the Ascending Aorta Wall Motion by Velocity Vector Imaging in Patients with Primary Hypertension

被引:6
作者
Wang, Lei [1 ]
Wang, Jing [1 ]
Xie, Mingxing [1 ]
Wang, Xinfang [1 ]
Lv, Qing [1 ]
Chen, Ming [1 ]
Zheng, Shaoping [1 ]
机构
[1] Huazhong Univ Sci & Technol, Dept Ultrasonog, Hubei Prov Key Lab Mol Imaging, Union Hosp,Tongji Med Coll, Wuhan 430022, Peoples R China
关键词
velocity vector imaging; hypertension; ascending aorta; anterior wall; RISK-FACTOR; STIFFNESS; ATHEROSCLEROSIS; DISTENSIBILITY; VALIDATION; THICKNESS; DIAMETER; DISEASE; ANGLE; FLOW;
D O I
10.1007/s11596-009-0127-z
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
We studied the wall motion characteristics of the ascending aorta by velocity vector imaging (VVI) in primary hypertension patients. The ascending aortas both in 30 patients with primary hypertension and 30 normal controls were examined by Acuson sequoia 512 equiped with VVI. The maximum velocity (Vs, Ve) of every point on the anterior wall of ascending aorta both in systole and diastole was measured. The aortic diameter was wider in the hypertension patients than that in the healthy subjects (P < 0.05). The movement amplitude of the anterior wall of the ascending aorta in long axis view in the hypertension patients was lower than that in the healthy subjects (P < 0.05). The motion and time to peak in systole of each point of the ascending aorta in the healthy subjects had no significant difference (P > 0.05). The velocity curves of the anterior wall of ascending aorta both in the hypertension and healthy subjects were regular, and the curve in systole was named S wave and that in diastole named E wave. The velocity of S wave and E wave was slower in the hypertension patients than that in the healthy subjects (P < 0.05). The time to peak of S wave on the anterior wall of ascending aorta in systole was shorter in the hypertension patients than in the healthy subjects (P < 0.05). VVI could be used to accurately and directly observe the movement character of the ascending aorta walls, which would help us understand the elasticity of great arteries in patients with hypertension.
引用
收藏
页码:127 / 130
页数:4
相关论文
共 50 条
[21]   Impaired cardiac and vascular motion in patients with Takayasu's arteritis: A velocity vector imaging-based study [J].
Yurdakul, Selen ;
Alibaz-Oner, Fatma ;
Direskeneli, Haner ;
Aytekin, Saide .
EUROPEAN JOURNAL OF RHEUMATOLOGY, 2018, 5 (01) :16-21
[22]   Morphology of the ascending aorta: a study on 114 Chinese patients [J].
Lei Liu ;
Wei Wang ;
Qingsheng Lu ;
Zaiping Jing ;
Suming Zhang ;
Bing Xu .
Journal of Interventional Medicine, 2018, 1 (01) :22-27
[23]   VECTOR FLOW IMAGING OF THE ASCENDING AORTA IN PATIENTS WITH TRICUSPID AND BICUSPID AORTIC VALVE STENOSIS TREATED WITH BIOLOGICAL AND MECHANICAL IMPLANTS [J].
Hansen, Kristoffer Lindskov ;
Moller-Sorensen, Hasse ;
Kjaergaard, Jesper ;
Jensen, Jorgen Arendt ;
Nielsen, Michael Bachmann .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (01) :64-72
[24]   Assessment of left ventricular wall motion in diabetic rats using velocity vector imaging combined with stress echocardiography [J].
Wei, Zhangrui ;
Su, Haili ;
Zhang, Haibin ;
Zhou, Xiaodong ;
Zhu, Ting ;
Liu, Liwen ;
Zhu, Yongsheng ;
He, Guangbin ;
Tian, Qiong ;
Zhang, Jun .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (06) :609-616
[25]   Evaluation of the asynchronization and function of the left ventricle in patients with chronic pulmonary hypertension by velocity vector imaging [J].
Wang Chao-hong ;
Wang Yue-heng ;
Niu Ning-ning ;
Xie Ying-xin ;
Wang Lin .
CHINESE MEDICAL JOURNAL, 2013, 126 (23) :4457-4462
[26]   Relation of aortic wall alterations and ascending aorta diameter in patients with bicuspid aortic valve [J].
Bauer, M ;
Meyer, R ;
Bauer, U ;
Goetze, N ;
Lange, PE ;
Hetzer, R .
ZEITSCHRIFT FUR KARDIOLOGIE, 2002, 91 (10) :818-824
[27]   Evaluation of the correlation of wall elasticity between different sections of radial artery by velocity vector imaging [J].
Tong, Ge ;
Gao, Yihua ;
Yuan, Dandan .
MEDICAL ULTRASONOGRAPHY, 2024, 26 (03) :264-269
[28]   Use of velocity vector imaging technology to evaluate the motion of myocardial infarction [J].
马莎 ;
王玉璟 ;
潘炎 .
South China Journal of Cardiology, 2012, 13 (03) :201-205
[29]   Clinical, imaging and surgical variability of postoperative pseudoaneurysm of the ascending aorta: Report of three cases [J].
Valdes-Dupeyron, Osvaldo ;
Nafeh-AbizReck, Manuel ;
Villar-Inclan, Alejandro ;
Hernandez-Nunez, Raiza ;
Carballo-Hidalgo, Rolando N. ;
Rodriguez-Rey, Katina ;
Chao Garcia, Jean L. .
CORSALUD, 2014, 6 (03) :259-265
[30]   ANALYSIS OF SYSTOLIC BACKFLOWAND SECONDARY HELICAL BLOOD FLOW IN THE ASCENDING AORTA USING VECTOR FLOW IMAGING [J].
Hansen, Kristoffer Lindskov ;
Moller-Sorensen, Hasse ;
Kjaergaard, Jesper ;
Jensen, Maiken Brit ;
Lund, Jens Teglgaard ;
Pedersen, Mads Moller ;
Lange, Theis ;
Jensen, Jorgen Arendt ;
Nielsen, Michael Bachmann .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (04) :899-908