Automated magnetic sorbent extraction based on octadecylsilane functionalized maghemite magnetic particles in a sequential injection system coupled with electrothermal atomic absorption spectrometry for metal determination

被引:41
|
作者
Giakisikli, Georgia [1 ]
Anthemidis, Aristidis N. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Fac Sci, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
Magnetic particles; Sequential injection; Column preconcentration; Metal determination; Electrothermal atomic absorption spectrometry; SOLID-PHASE EXTRACTION; OPTICAL-EMISSION-SPECTROMETRY; BIOLOGICAL SAMPLES PRIOR; TRACE HEAVY-METALS; ON-VALVE SYSTEM; PRECONCENTRATION SYSTEM; ONLINE PRECONCENTRATION; ENVIRONMENTAL-SAMPLES; CARBON NANOTUBES; NATURAL-WATERS;
D O I
10.1016/j.talanta.2013.02.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new automatic sequential injection (SI) system for on-line magnetic sorbent extraction coupled with electrothermal atomic absorption spectrometry (ETAAS) has been successfully developed for metal determination. In this work, we reported effective on-line immobilization of magnetic silica particles into a microcolumn by the external force of two strong neodymium iron boron (NdFeB) magnets across it, avoiding the use of frits. Octadecylsilane functionalized maghemite magnetic particles were used as sorbent material. The potentials of the system were demonstrated for trace cadmium determination in water samples. The method was based on the on-line complex formation with diethyldithiocarbamate (DDTC), retention of Cd-DDTC on the surface of the MPs and elution with isobutyl methyl ketone (IBMK). The formation mechanism of the magnetic solid phase packed column and all critical parameters (chemical, flow, graphite furnace) influencing the performance of the system were optimized and offered good analytical characteristics. For 5 mL sample volume, a detection limit of 3 ng L-1, a relative standard deviation of 3.9% at 50 ng L-1 level (n=11) and a linear range of 9-350 ng L-1 were obtained. The column remained stable for more than 600 cycles keeping the cost down in routine analysis. The proposed method was evaluated by analyzing certified reference materials and natural waters. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 50 条
  • [21] Selenium speciation using capillary electrophoresis coupled with modified electrothermal atomic absorption spectrometry after selective extraction with 5-sulfosalicylic acid functionalized magnetic nanoparticles
    Yan, Lizhen
    Deng, Biyang
    Shen, Caiying
    Long, Chanjuan
    Deng, Qiufen
    Tao, Chunyao
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1395 : 173 - 179
  • [22] Implementation of suitable flow injection/sequential injection-sample separation/preconcentration schemes for determination of trace metal concentrations using detection by electrothermal atomic absorption spectrometry and inductively coupled plasma mass spectrometry
    Hansen, EH
    Wang, JH
    ANALYTICA CHIMICA ACTA, 2002, 467 (1-2) : 3 - 12
  • [23] Sequential injection solvent dispersive micro solid phase extraction (SI-SD-μSPE) platform coupled with atomic absorption spectrometry for lead determination in water samples
    Stamna, Antonia
    Anthemidis, Aristidis N.
    MICROCHEMICAL JOURNAL, 2020, 156
  • [24] An automated flow injection system for metal determination by flame atomic absorption spectrometry involving on-line fabric disk sorptive extraction technique
    Anthemidis, A.
    Kazantzi, V.
    Samanidou, V.
    Kabir, A.
    Furton, K. G.
    TALANTA, 2016, 156 : 64 - 70
  • [25] UNMODIFIED MULTI-WALLED CARBON NANOTUBES AS SORBENT MATERIAL IN FLOW INJECTION ON-LINE SORBENT EXTRACTION PRECONCENTRATION SYSTEM FOR CADMIUM DETERMINATION BY FLAME ATOMIC ABSORPTION SPECTROMETRY
    Anthemidis, Aristidis N.
    Paschalidou, Magdalini
    ANALYTICAL LETTERS, 2012, 45 (09) : 1098 - 1110
  • [26] Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples
    Georgia Giakisikli
    Alejandro Ayala Quezada
    Junpei Tanaka
    Aristidis N. Anthemidis
    Hiroya Murakami
    Norio Teshima
    Tadao Sakai
    Analytical Sciences, 2015, 31 : 383 - 389
  • [27] Magnetic dispersive solid phase extraction using modified magnetic multi-walled carbon nanotubes combined with electrothermal atomic absorption spectrometry for the determination of selenium
    Firouzabadi, Zahra Dehghani
    Dadfarnia, Shayessteh
    Shabani, Ali Mohammad Haji
    Ehrampoush, Mohammad Hassan
    Tafti, Elaheh Nourbala
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2018, 98 (06) : 555 - 569
  • [28] SIMULTANEOUS SOLID PHASE CHELATE EXTRACTION FOR ULTRATRACE DETERMINATION OF COPPER, NICKEL, AND ZINC BY MICROSAMPLE INJECTION SYSTEM COUPLED FLAME ATOMIC ABSORPTION SPECTROMETRY
    Sert, Ramazan
    Hol, Aysen
    Kartal, Aslihan Arslan
    Akdogan, Abdullah
    Elci, Aydan
    Baig, Jameel Ahmed
    Divrikli, Umit
    Elci, Latif
    ANALYTICAL LETTERS, 2013, 46 (16) : 2570 - 2582
  • [29] Preconcentration of heavy metal ions on magnetic multi-walled carbon nanotubes using magnetic solid-phase extraction and determination in vegetable samples by electrothermal atomic absorption spectrometry: Box–Behnken design
    Sara Khodadadi
    Elahe Konoz
    Ali Niazi
    Ali Ezabadi
    Chemical Papers, 2022, 76 : 6735 - 6751
  • [30] Ligandless dispersive solid phase extraction of cobalt ion using magnetic graphene oxide as an adsorbent followed by its determination with electrothermal atomic absorption spectrometry
    AlKinani, Alaa
    Eftekhari, Mohammad
    Gheibi, Mohammad
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2021, 101 (01) : 17 - 34