Automated magnetic sorbent extraction based on octadecylsilane functionalized maghemite magnetic particles in a sequential injection system coupled with electrothermal atomic absorption spectrometry for metal determination

被引:41
|
作者
Giakisikli, Georgia [1 ]
Anthemidis, Aristidis N. [1 ]
机构
[1] Aristotle Univ Thessaloniki, Fac Sci, Dept Chem, Analyt Chem Lab, Thessaloniki 54124, Greece
关键词
Magnetic particles; Sequential injection; Column preconcentration; Metal determination; Electrothermal atomic absorption spectrometry; SOLID-PHASE EXTRACTION; OPTICAL-EMISSION-SPECTROMETRY; BIOLOGICAL SAMPLES PRIOR; TRACE HEAVY-METALS; ON-VALVE SYSTEM; PRECONCENTRATION SYSTEM; ONLINE PRECONCENTRATION; ENVIRONMENTAL-SAMPLES; CARBON NANOTUBES; NATURAL-WATERS;
D O I
10.1016/j.talanta.2013.02.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new automatic sequential injection (SI) system for on-line magnetic sorbent extraction coupled with electrothermal atomic absorption spectrometry (ETAAS) has been successfully developed for metal determination. In this work, we reported effective on-line immobilization of magnetic silica particles into a microcolumn by the external force of two strong neodymium iron boron (NdFeB) magnets across it, avoiding the use of frits. Octadecylsilane functionalized maghemite magnetic particles were used as sorbent material. The potentials of the system were demonstrated for trace cadmium determination in water samples. The method was based on the on-line complex formation with diethyldithiocarbamate (DDTC), retention of Cd-DDTC on the surface of the MPs and elution with isobutyl methyl ketone (IBMK). The formation mechanism of the magnetic solid phase packed column and all critical parameters (chemical, flow, graphite furnace) influencing the performance of the system were optimized and offered good analytical characteristics. For 5 mL sample volume, a detection limit of 3 ng L-1, a relative standard deviation of 3.9% at 50 ng L-1 level (n=11) and a linear range of 9-350 ng L-1 were obtained. The column remained stable for more than 600 cycles keeping the cost down in routine analysis. The proposed method was evaluated by analyzing certified reference materials and natural waters. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:229 / 235
页数:7
相关论文
共 50 条
  • [1] Extraction and preconcentration of trace levels of cobalt using functionalized magnetic nanoparticles in a sequential injection lab-on-valve system with detection by electrothermal atomic absorption spectrometry
    Wang, Yang
    Luo, Xiaoyu
    Tang, Jie
    Hu, Xiaoya
    Xu, Qin
    Yang, Chun
    ANALYTICA CHIMICA ACTA, 2012, 713 : 92 - 96
  • [2] Determination of copper in seawater by using a sequential injection system incorporating a sample pretreatment module coupled to electrothermal atomic absorption spectrometry
    Yu Yong-Liang
    Du Zhuo
    Wang Jian-Hua
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (03) : 431 - 434
  • [3] A sequential injection on-line column preconcentration system for determination of cadmium by electrothermal atomic absorption spectrometry
    Xu, ZR
    Pan, HY
    Xu, SK
    Fang, ZL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2000, 55 (03) : 213 - 219
  • [4] Preparation of a functionalized magnetic metal-organic framework sorbent for the extraction of lead prior to electrothermal atomic absorption spectrometer analysis
    Wang, Yang
    Xie, Jing
    Wu, Yichun
    Ge, Huali
    Hu, Xiaoya
    JOURNAL OF MATERIALS CHEMISTRY A, 2013, 1 (31) : 8782 - 8789
  • [5] Development of an automated sequential injection on-line solvent extraction-back extraction procedure as demonstrated for the determination of cadmium with detection by electrothermal atomic absorption spectrometry
    Wang, JH
    Hansen, EH
    ANALYTICA CHIMICA ACTA, 2002, 456 (02) : 283 - 292
  • [6] Magnetic Nanoparticles Coated with Ionic Liquid as a Sorbent for Solid Phase Extraction of Chromium(VI) Prior to Its Determination by Electrothermal Atomic Absorption Spectrometry
    Karimi, Mehdi
    Shabani, Ali M. H.
    Dadfarnia, Shayessteh
    JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 2016, 27 (01) : 144 - 152
  • [7] Combination of a magnetic ionic liquid and magnetic particles for the determination of Pb(II) and Sn(IV) using electrothermal atomic absorption spectrometry
    Munoz-Sandoval, Maria Jose
    Vicente-Martinez, Yesica
    Hernandez-Cordoba, Manuel
    Lopez-Garcia, Ignacio
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2024, 216
  • [8] Automatic On-line Solid-phase Extraction-Electrothermal Atomic Absorption Spectrometry Exploiting Sequential Injection Analysis for Trace Vanadium, Cadmium and Lead Determination in Human Urine Samples
    Giakisikli, Georgia
    Quezada, Alejandro Ayala
    Tanaka, Junpei
    Anthemidis, Aristidis N.
    Murakami, Hiroya
    Teshima, Norio
    Sakai, Tadao
    ANALYTICAL SCIENCES, 2015, 31 (05) : 383 - 389
  • [9] Non-chromatographic determination of ultratraces of V(V) and V(IV) based on a double column solid phase extraction flow injection system coupled to electrothermal atomic absorption spectrometry
    Leticia Kim, Manuela
    Beatriz Tudino, Mabel
    TALANTA, 2009, 79 (03) : 940 - 946
  • [10] An automatic on-line sol-gel pyridylethylthiopropyl functionalized silica-based sorbent extraction system coupled to flame atomic absorption spectrometry for lead and copper determination in beer samples
    Manousi, Natalia
    Kabir, Abuzar
    Furton, Kenneth G.
    Stathogiannopoulou, Magdalini
    Drosaki, Eleni
    Anthemidis, Aristidis
    FOOD CHEMISTRY, 2022, 394