In-channel electrochemical detection for microchip capillary electrophoresis using an electrically isolated potentiostat

被引:161
|
作者
Martin, RS
Ratzlaff, KL
Huynh, BH
Lunte, SM
机构
[1] Univ Kansas, Dept Pharmaceut Chem, Lawrence, KS 66047 USA
[2] Univ Kansas, Ctr Bioanalyt Res, Lawrence, KS 66047 USA
[3] Univ Kansas, Dept Chem, Instrumentat Design Lab, Lawrence, KS 66045 USA
关键词
D O I
10.1021/ac011087p
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new electrode configuration for microchip capillary electrophoresis (CE) with electrochemical (EC) detection, is described. This approach makes it possible to place the working electrode directly in the separation channel. The "in-channel" EC detection was accomplished without the use of a decoupler through the utilization of a specially designed, electrically isolated potentiostat. The effect of the working electrode position on the separation performance (in terms of plate height and peak skew) of poly(dimethylsiloxane)-based microchip CEEC devices was evaluated by comparing the more commonly used end-channel configuration with this new in-channel approach. Using catechol as the test analyte, it was found that in-channel EC detection decreased the total plate height by a factor of 4.6 and lowered the peak skew by a factor of 1.3. A similar trend was observed for the small, inorganic ion nitrite. Furthermore, a fluorescent and electrochemically active amino acid derivative was used to directly compare the separation performance of in-channel EC detection to that of a widely used laser-induced fluorescence (LIF) detection scheme. In this case, it was found that the plate height and peak skew for both detection schemes were essentially equal, and the separation performance of in-channel EC detection is comparable to LIF, detection.
引用
收藏
页码:1136 / +
页数:72
相关论文
共 50 条
  • [1] In-channel amperometric detection for microchip electrophoresis using a wireless isolated potentiostat
    Gunasekara, Dulan B.
    Hulvey, Matthew K.
    Lunte, Susan M.
    ELECTROPHORESIS, 2011, 32 (08) : 832 - 837
  • [2] In-channel simplified decoupler with renewable electrochemical detection for microchip capillary electrophoresis
    Lin, Kuan-Wen
    Huang, Yan-Kai
    Su, Hsiu-Li
    Hsieh, You-Zung
    ANALYTICA CHIMICA ACTA, 2008, 619 (01) : 115 - 121
  • [3] Enhanced aminophenols monitoring using in-channel amperometric detection with dual-channel microchip capillary electrophoresis
    Chuanpin Chen
    Jong Hoon Hahn
    Environmental Chemistry Letters, 2011, 9 : 491 - 497
  • [4] Enhanced aminophenols monitoring using in-channel amperometric detection with dual-channel microchip capillary electrophoresis
    Chen, Chuanpin
    Hahn, Jong Hoon
    ENVIRONMENTAL CHEMISTRY LETTERS, 2011, 9 (04) : 491 - 497
  • [5] Low electric field DNA separation and in-channel amperometric detection by microchip capillary electrophoresis
    Ghanim, Motasem Hilmi
    Najimudin, Nazalan
    Ibrahim, Kamarulazizi
    Abdullah, Mohd Zaid
    IET NANOBIOTECHNOLOGY, 2014, 8 (02) : 77 - 82
  • [6] Evaluation of in-channel amperometric detection using a dual-channel microchip electrophoresis device and a two-electrode potentiostat for reverse polarity separations
    Meneses, Diogenes
    Gunasekara, Dulan B.
    Pichetsurnthorn, Pann
    da Silva, Jose A. F.
    de Abreu, Fabiane C.
    Lunte, Susan M.
    ELECTROPHORESIS, 2015, 36 (03) : 441 - 448
  • [7] Microchip capillary electrophoresis with electrochemical detection
    Zeng, Y
    Chen, H
    Pang, DW
    Wang, ZL
    Cheng, JK
    ANALYTICAL CHEMISTRY, 2002, 74 (10) : 2441 - 2445
  • [8] Dual-channel method for interference-free in-channel amperometric detection in microchip capillary electrophoresis
    Chen, Chuanpin
    Hahn, Jong Hoon
    ANALYTICAL CHEMISTRY, 2007, 79 (18) : 7182 - 7186
  • [9] Capillary electrophoresis and microchip capillary electrophoresis with electrochemical and electrochemiluminescence detection
    Du, Yan
    Wang, Erkang
    JOURNAL OF SEPARATION SCIENCE, 2007, 30 (06) : 875 - 890
  • [10] Nanoband electrode for high-performance in-channel amperometric detection in dual-channel microchip capillary electrophoresis
    Chen, Chuanpin
    Teng, Wei
    Hahn, Jong Hoon
    ELECTROPHORESIS, 2011, 32 (08) : 838 - 843