Evaluation of the In Vivo Efficiency and Safety of Hepatic Radiofrequency Ablation Using a 15-G Octopus® in Pig Liver

被引:10
作者
Lee, Eun Sun [1 ]
Lee, Jeong Min [1 ,2 ]
Kim, Kyung Won [1 ]
Lee, In Joon [3 ]
Han, Joon Koo [1 ,2 ]
Choi, Byung Ihn [1 ,2 ]
机构
[1] Seoul Natl Univ, Coll Med, Dept Radiol, Seoul 110744, South Korea
[2] Seoul Natl Univ, Coll Med, Inst Radiat Med, Seoul 110744, South Korea
[3] Natl Canc Ctr, Seoul 410769, South Korea
关键词
Pulsed radiofrequency treatment; Liver; Ablation techniques; SMALL HEPATOCELLULAR-CARCINOMA; INTERNALLY COOLED ELECTRODES; TISSUE ABLATION; ETHANOL INJECTION; EX-VIVO; PERFUSION ELECTRODE; MULTIPLE; MONOPOLAR; VOLUME; TUMORS;
D O I
10.3348/kjr.2013.14.2.194
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To determine in vivo efficacy of radiofrequency ablation (RFA) in porcine Liver by using 15-gauge Octopus (R) (15-G Octopus (R)) electrodes to create a large coagulation. Materials and Methods: A total of 18 coagulations were created by using a 180-W generator and 15-G Octopus (R) electrodes during laparotomy, performed in 14 pigs. Coagulation necrosis was created in the pig Livers by the use of one of three RFA protocols: 1) group A, monopolar RFA using a 15-G Octopus (R) electrode with a 5-mm inter-electrode distance (n = 4); 2) group B, monopolar RFA using a 15-G Octopus (R) electrode with a 10-mm inter-electrode distance (n = 6); and 3) group C, switching monopolar RFA using two 15-G Octopus (R) electrodes (n = 8). The energy efficiency, shape, maximum and minimum diameters (Dmx and Dmi), and the volume of the coagulation volume were measured in each group. The Summary statistics were obtained and Mann-Whitney test was were performed. Results: The mean ablated volume of each group was 49.23 cm(3) in A, 64.11 cm(3) in B, and 72.35 cm(3) in C. The mean Dmx and Dmi values were 5.68 cm and 4.58 cm in A and 5.97 cm and 4.97 cm in B, respectively. In group C, the mean diameters of Dmx and Dmi were 6.80 cm and 5.11 cm, respectively. The mean ratios of Dmi/Dmx were 1.25, 1.20, and 1.35 in groups A, B, and C, respectively. There was one animal death during the RFA procedure, the cause of which could not be subsequently determined. However, there were no other significant, procedure-related complications during the seven-hour-delayed CT scans. Conclusion: RFA procedures using 15-G Octopus (R) electrodes are useful and safe for creating a large ablation in a single electrode model as well as in the multiple electrodes model.
引用
收藏
页码:194 / 201
页数:8
相关论文
共 22 条
[1]   Radiofrequency ablation of unresectable primary and metastatic hepatic malignancies - Results in 123 patients [J].
Curley, SA ;
Izzo, F ;
Delrio, P ;
Ellis, LM ;
Granchi, J ;
Vallone, P ;
Fiore, F ;
Pignata, S ;
Daniele, B ;
Cremona, F .
ANNALS OF SURGERY, 1999, 230 (01) :1-8
[2]   Radiofrequency ablation of liver tumours: systematic review [J].
Decadt, B ;
Siriwardena, AK .
LANCET ONCOLOGY, 2004, 5 (09) :550-560
[3]   Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases [J].
Goldberg, SN ;
Solbiati, L ;
Hahn, PF ;
Cosman, E ;
Conrad, JE ;
Fogle, R ;
Gazelle, GS .
RADIOLOGY, 1998, 209 (02) :371-379
[4]  
GOLDBERG SN, 1995, ACAD RADIOL, V2, P399
[5]  
Goldberg SN, 1996, ACAD RADIOL, V3, P636
[6]   Percutaneous Radiofrequency Ablation of Hepatocellular Carcinomas Adjacent to the Gallbladder with Internally Cooled Electrodes: Assessment of Safety and Therapeutic Efficacy [J].
Kim, Sang Won ;
Rhim, Hyunchul ;
Park, Mihyun ;
Kim, Heejung ;
Kim, Young-sun ;
Choi, Dongil ;
Lim, Hyo K. .
KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (04) :366-376
[7]   Multiple-electrode radiofrequency ablations using Octopus® electrodes in an in vivo porcine liver model [J].
Lee, E. S. ;
Lee, J. M. ;
Kim, W. S. ;
Choi, S. H. ;
Joo, I. ;
Kim, M. ;
Yoo, D. H. ;
Yoo, R-E ;
Han, J. K. ;
Choi, B. I. .
BRITISH JOURNAL OF RADIOLOGY, 2012, 85 (1017) :E609-E615
[8]   Switching monopolar radiofrequency ablation technique using multiple, internally cooled electrodes and a multichannel generator - Ex vivo and in vivo pilot study [J].
Lee, Jeong Min ;
Han, Joon Koo ;
Kim, Hyo Cheol ;
Choi, Young Hun ;
Kim, Se Hyung ;
Choi, Jin Young ;
Choi, Byung Ihn .
INVESTIGATIVE RADIOLOGY, 2007, 42 (03) :163-171
[9]   Hepatic radiofrequency ablation using multiple probes:: Ex vivo and in vivo comparative studies of monopolar versus multipolar modes [J].
Lee, Jeong Min ;
Han, Joon Koo ;
Lee, Jae Young ;
Kim, Se Hyung ;
Choi, Jin Young ;
Lee, Min Woo ;
Choi, Seung Hong ;
Eo, Hong ;
Choi, Byung Ihn .
KOREAN JOURNAL OF RADIOLOGY, 2006, 7 (02) :106-117
[10]   Radiofrequency ablation of the porcine liver in vivo: Increased coagulation with an internally cooled perfusion electrode [J].
Lee, JM ;
Han, JK ;
Chang, JM ;
Chung, SY ;
Kim, SH ;
Lee, JY ;
Lee, MW ;
Choi, BI .
ACADEMIC RADIOLOGY, 2006, 13 (03) :343-352