Novel sucrose three-enzyme conductometric biosensor

被引:39
作者
Soldatkin, O. O. [1 ]
Peshkova, V. M. [1 ,2 ]
Dzyadevych, S. V. [1 ]
Soldatkin, A. P. [1 ]
Jaffrezic-Renault, N. [3 ]
El'skaya, A. V. [1 ]
机构
[1] Natl Acad Sci Ukraine, Lab Biomol Elect, Inst Mol Biol & Genet, UA-03143 Kiev, Ukraine
[2] Natl Taras Shevchenko Univ Kiev, UA-01033 Kiev, Ukraine
[3] Univ Lyon 1, CNRS, UMR 5180, Sci Analyt Lab, F-69622 Villeurbanne, France
来源
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS | 2008年 / 28卷 / 5-6期
关键词
conductometric biosensor; invertase; mutarotase; sucrose;
D O I
10.1016/j.msec.2007.10.034
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
For the first time a conductometric biosensor for sucrose determination has been developed using a complex three-enzyme (invertase, mutarotase, and glucose oxidase) containing membrane as a sensitive element immobilized on the conductometric interdigitated planar electrodes. The time of measurement of sucrose concentration in the solution was about 1-2 min. The dynamic range of biosensor depends on buffer capacity, being 2 mu M-5 mM of sucrose in 5 mM phosphate buffer. The conductometric biosensor developed demonstrates high selectivity, operational stability and reproducibility. The dependence of sensor response on pH and ionic strength of tested solution has been studied in this work. Storage conditions have also been under investigation. The sensor appeared to be eligible towards application in practice. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:959 / 964
页数:6
相关论文
共 21 条
  • [1] HYBRID BIOSENSOR FOR THE DETERMINATION OF SUCROSE
    BARLIKOVA, A
    SVORC, J
    MIERTUS, S
    [J]. ANALYTICA CHIMICA ACTA, 1991, 247 (01) : 83 - 87
  • [2] DZYADEVICH SV, 1994, RUSSIAN J ELECTROCHE, V30, P982
  • [3] Dzyadevych S. V., 2005, Biopolimery i Kletka, V21, P91
  • [4] OXYGEN-STABILIZED ENZYME ELECTRODE FOR D-GLUCOSE ANALYSIS IN FERMENTATION BROTHS
    ENFORS, SO
    [J]. ENZYME AND MICROBIAL TECHNOLOGY, 1981, 3 (01) : 29 - 32
  • [5] Enzymatic membranes for determination of some disaccharides by means of an oxygen electrode
    Filipiak, M
    Fludra, K
    Gosciminska, E
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (04) : 355 - 364
  • [6] Enhancement of operational stability of an enzyme biosensor for glucose and sucrose using protein based stabilizing agents
    Gouda, MD
    Kumar, MA
    Thakur, MS
    Karanth, NG
    [J]. BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) : 503 - 507
  • [7] GUEMAS Y, 2000, APPL BIOCHEM BIOTECH, V89, P81
  • [8] HERBRETEAU B, 1990, HRC-J HIGH RES CHROM, V13, P239, DOI 10.1002/jhrc.1240130405
  • [9] An amperometric flow injection analysis enzyme sensor for sucrose using a tetracyanoquinodimethane modified graphite paste electrode
    Lima, JL
    Pandey, PC
    Weetall, HH
    [J]. BIOSENSORS & BIOELECTRONICS, 1996, 11 (08) : 719 - 723
  • [10] LOWERY LP, 1994, ANAL CHEM, V66, P1752