Volar versus dorsal plating in the management of intra-articular distal radius fractures

被引:169
|
作者
Ruch, DS [1 ]
Papadonikolakis, A [1 ]
机构
[1] Duke Univ, Med Ctr, Div Orthopaed Surg, Durham, NC 27710 USA
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 2006年 / 31A卷 / 01期
关键词
distal; dorsal; fractures; plating; radius; volar;
D O I
10.1016/j.jhsa.2005.09.011
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose: To compare the complications and functional and radiographic outcomes of volar and dorsal plating of intra-articular distal radius fractures. Methods: This retrospective review included 34 patients found by searching a database of 350 patients treated for distal radius fractures. Inclusion criteria were (1) at least 1 year of follow-up data and (2) open reduction and internal fixation of a multifragmentary fragment intra-articular distal radius fracture with either a nonlocking volar or dorsal plate. Twenty patients were treated with a dorsal plate and 14 patients were treated with a volar nonlocking plate. Objective and subjective outcome parameters were compared between the 2 groups. Objective evaluations included wrist range of motion, grip strength, and preoperative and postoperative radiographic parameters (radial inclination, palmar tilt, ulnar variance, fracture pattern). Subjective evaluations were performed using the Disabilities of the Arm, Shoulder, and Hand (DASH) questionnaire score and the Gartland and Werley score. Results: Volar plating resulted in a significantly better Gartland-Werley score compared with dorsal plating. There were no significant differences in the DASH score.Volar collapse was documented in 5 of the 20 patients in the dorsal plating group, which resulted in a mild loss of pronation compared with the volar plating group. No collapse occurred in the volar plating group. In addition the difference in the percentage of wrist range of motion compared with the contralateral wrist was not significant. Dorsal plating was associated with a ruptured extensor indicis tendon in 1 patient; secondary surgical procedures were required in 4 patients (tenolyses and radial styloidectomy). Volar plating was associated with median nerve neuropathy in 2 patients and intersection syndrome in one. Conclusions: Although both groups of patients had similar DASH scores the functional outcome in terms of Gartland and Werley scores was better in the volar plating group. In addition there was a higher rate of volar collapse and late complications in the dorsal plating group compared with the volar plating group.
引用
收藏
页码:9 / 16
页数:8
相关论文
共 50 条
  • [41] Intra-Articular Fractures of the Hand
    Oak, Nikhil
    Lawton, Jeffrey N.
    HAND CLINICS, 2013, 29 (04) : 535 - +
  • [42] Complications after volar plate synthesis for distal radius fractures
    Pacchiarini, Luca
    Oldrini, Lorenzo Massimo
    Feltri, Pietro
    Lucchina, Stefano
    Filardo, Giuseppe
    Candrian, Christian
    EFORT OPEN REVIEWS, 2024, 9 (06) : 580 - 580
  • [43] Intraarticular Distal End Radius Fractures Treated with Volar Locking Plate Variations
    Gaonkar, Nishant
    Patil, Nitin
    Kolekar, Anupam
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1030 - S1032
  • [44] Volar plate versus k-wire fixation of distal radius fractures
    Brennan, Stephen A.
    Kiernan, Christine
    Beecher, Suzanne
    O'Reilly, Rory T.
    Devitt, Brian M.
    Kearns, Stephen R.
    O'Sullivan, Michael E.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2016, 47 (02): : 372 - 376
  • [45] Complications following dorsal versus volar plate fixation of distal radius fracture: A meta-analysis
    Wei, Jie
    Yang, Tu-Bao
    Luo, Wei
    Qin, Jia-Bi
    Kong, Fan-Jing
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (02) : 265 - 275
  • [46] Complications of Low-Profile Dorsal Versus Volar Locking Plates in the Distal Radius: A Comparative Study
    Yu, Yangyang R.
    Makhni, Melvin C.
    Tabrizi, Shervin
    Rozental, Tamara D.
    Mundanthanam, George
    Day, Charles S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (07): : 1135 - 1141
  • [47] Biomechanics of Subcutaneous Locked Plating Versus Burke Plate and External Fixator for Comminuted Distal Radius Fractures
    Fleifel, Dominik
    Pytiak, Andrew V.
    Jin, Xin
    Cizmic, Zlatan
    Vaidya, Rahul
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [48] Comparison of 4 Fluoroscopic Views for Dorsal Cortex Screw Penetration After Volar Plating of the Distal Radius
    Ozer, Kagan
    Wolf, Jennifer M.
    Watkins, Bruce
    Hak, David J.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (05): : 963 - 967
  • [49] Volar Locking Plate Fixation for Distal Radius Fractures Distal to the Watershed Line with an Intact Lunate Volar Rim
    Cha, Soo Min
    Shin, Hyun Dae
    Kim, Seung Won
    JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2023, 28 (06) : 708 - 716
  • [50] Hardware-Related Complications After Dorsal Plating for Displaced Distal Radius Fractures
    Matzon, Jonas L.
    Kenniston, Julia
    Beredjiklian, Pedro K.
    ORTHOPEDICS, 2014, 37 (11) : E978 - E982