Retinal oxygen metabolism in healthy subjects and glaucoma patients

被引:69
作者
Olafsdottir, Olof Birna [1 ]
Vandewalle, Evelien [2 ,3 ]
Pinto, Luis Abegao [4 ]
Geirsdottir, Asbjorg [1 ,5 ]
De Clerck, Eline [3 ]
Stalmans, Peter [3 ]
Gottfredsdottir, Maria Soffia [5 ]
Kristjansdottir, Jona Valgerdur [5 ]
Van Calster, Joachim [3 ]
Zeyen, Thierry [3 ]
Stefansson, Einar [1 ,5 ]
Stalmans, Ingeborg [2 ,3 ]
机构
[1] Univ Iceland, Dept Ophthalmol, Reykjavik, Iceland
[2] Katholieke Univ Leuven, Lab Ophthalmol, Dept Ophthalmol Neurosci, Louvain, Belgium
[3] Katholieke Univ Leuven Hosp, Dept Ophthalmol, B-3000 Louvain, Belgium
[4] Univ Lisbon, Fac Med, Dept Pharmacol & Neurosci, P-1699 Lisbon, Portugal
[5] Natl Univ Hosp Iceland, Landspitali, Dept Ophthalmol, Reykjavik, Iceland
关键词
GOLDMANN APPLANATION TONOMETER; ICARE TONOMETER; VESSEL DIAMETER; BLOOD-FLOW; SATURATION; DORZOLAMIDE; OXIMETRY; EYES;
D O I
10.1136/bjophthalmol-2013-303162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background To test whether retinal oxygen metabolism is different in glaucoma patients compared with healthy subjects. Methods This was a two-centre study where retinal vessel oxygen saturation was measured in glaucoma patients and healthy individuals with a non-invasive spectrophotometric retinal oximeter. Visual fields were obtained in the glaucoma patients. Results No statistical difference was found in retinal oxygen saturation in arterioles (p=0.16), venules (p=0.16) and arteriovenous difference (p=0.24) when all glaucoma patients (n=74) were compared with healthy individuals (n=89). When patients with advanced glaucoma (visual field mean defect (MD >= 10 dB, n=21)) were compared with healthy individuals, the oxygen saturation in venules was higher in glaucoma patients (58.2%+/-5.4% vs 53.8%+/-6.4%; p=0.0054, mean+/-SD) and the arteriovenous difference was lower in glaucoma patients (36.4%+/-4.7% vs 39.5%+/-5.7%; p=0.021). In glaucoma patients with mild glaucoma (visual field MD <= 5 dB, n=33), no statistical differences were found in retinal oxygen saturation compared with healthy individuals. Conclusions Glaucoma patients with advanced glaucoma have higher oxygen saturation in venules and lower arteriovenous difference in oxygen saturation compared with healthy individuals. The decreased arteriovenous difference in severe glaucoma may be related to lower oxygen consumption secondary to neuropathy.
引用
收藏
页码:329 / 333
页数:5
相关论文
共 21 条
  • [1] Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation
    Beach, JM
    Schwenzer, KJ
    Srinivas, S
    Kim, D
    Tiedeman, JS
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) : 748 - 758
  • [2] Reliability of vessel diameter measurements with a retinal oximeter
    Blondal, Renata
    Sturludottir, Margret Kara
    Hardarson, Sveinn Hakon
    Halldorsson, Gisli Hreinn
    Stefansson, Einar
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 249 (09) : 1311 - 1317
  • [3] Comparison of ICare tonometer with Goldmann applanation tonometer in glaucoma patients
    Brusini, P
    Salvetat, ML
    Zeppieri, M
    Tosoni, C
    Parisi, L
    [J]. JOURNAL OF GLAUCOMA, 2006, 15 (03) : 213 - 217
  • [4] Flammer J, 1994, Surv Ophthalmol, V38 Suppl, pS3, DOI 10.1016/0039-6257(94)90041-8
  • [5] The impact of ocular blood flow in glaucoma
    Flammer, J
    Orgül, S
    Costa, VP
    Orzalesi, N
    Krieglstein, GK
    Serra, LM
    Renard, JP
    Stefánsson, E
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 2002, 21 (04) : 359 - 393
  • [6] Retinal Vessel Oxygen Saturation in Healthy Individuals
    Geirsdottir, Asbjorg
    Palsson, Olafur
    Hardarson, Sveinn Hakon
    Olafsdottir, Olof Birna
    Kristjansdottir, Jona Valgerdur
    Stefansson, Einar
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (09) : 5433 - 5442
  • [7] Gottfredsdottir MS, 2011, ARVO M, V52, P5668
  • [8] Automatic retinal oximetry
    Hardarson, Sveinn Hakon
    Harris, Alon
    Karlsson, Robert Arnar
    Halldorsson, Gisli Hreinn
    Kagemann, Larry
    Rechtman, Ehud
    Zoega, Gunnar Mar
    Eysteinsson, Thor
    Benediktsson, Jon Atli
    Thorsteinsson, Adalbjorn
    Jensen, Peter Koch
    Beach, James
    Stefansson, Einar
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (11) : 5011 - 5016
  • [9] Glaucoma Filtration Surgery and Retinal Oxygen Saturation
    Hardarson, Sveinn Hakon
    Gottfredsdottir, Maria Soffia
    Halldorsson, Gisli Hreinn
    Karlsson, Robert Arnar
    Benediktsson, Jon Atli
    Eysteinsson, Thor
    Beach, James M.
    Harris, Alon
    Stefansson, Einar
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (11) : 5247 - 5250
  • [10] A review of methods for human retinal oximetry
    Harris, A
    Dinn, RB
    Kagemann, L
    Rechtman, E
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2003, 34 (02) : 152 - 164