EquiMoves: A Wireless Networked Inertial Measurement System for Objective Examination of Horse Gait

被引:73
作者
Bosch, Stephan [1 ,5 ]
Braganca, Filipe Serra [2 ]
Marin-Perianu, Mihai [1 ]
Marin-Perianu, Raluca [1 ]
van der Zwaag, Berend Jan [1 ]
Voskamp, John [3 ]
Back, Willem [2 ,4 ]
van Weeren, Rene [2 ]
Havinga, Paul [5 ]
机构
[1] Inertia Technol BV, NL-7521 AG Enschede, Netherlands
[2] Univ Utrecht, Fac Vet Med, Dept Equine Sci, NL-3584 CM Utrecht, Netherlands
[3] Rosmark Consultancy, NL-6733 AA Wekerom, Netherlands
[4] Univ Ghent, Fac Vet Med, Dept Surg & Anaesthesia Domest Anim, B-9820 Merelbeke, Belgium
[5] Univ Twente, Pervas Syst Grp, Dept Comp Sci, NL-7522 NB Enschede, Netherlands
关键词
horse; gait analysis; lameness; IMU; optical motion capture; agreement analysis; GROUND REACTION FORCES; HIND-LIMB LAMENESS; MEASUREMENT UNIT; SUBJECTIVE LAMENESS; MOTION CAPTURE; SENSOR SYSTEM; MOVEMENT ADAPTATIONS; DISTAL LIMB; FORELIMB; KINEMATICS;
D O I
10.3390/s18030850
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, we describe and validate the EquiMoves system, which aims to support equine veterinarians in assessing lameness and gait performance in horses. The system works by capturing horse motion from up to eight synchronized wireless inertial measurement units. It can be used in various equine gait modes, and analyzes both upper-body and limb movements. The validation against an optical motion capture system is based on a Bland-Altman analysis that illustrates the agreement between the two systems. The sagittal kinematic results (protraction, retraction, and sagittal range of motion) show limits of agreement of +/- 2.3 degrees and an absolute bias of 0.3 degrees in the worst case. The coronal kinematic results (adduction, abduction, and coronal range of motion) show limits of agreement of -8.8 and 8.1 degrees, and an absolute bias of 0.4 degrees in the worst case. The worse coronal kinematic results are most likely caused by the optical system setup (depth perception difficulty and suboptimal marker placement). The upper-body symmetry results show no significant bias in the agreement between the two systems; in most cases, the agreement is within +/- 5 mm. On a trial-level basis, the limits of agreement for withers and sacrum are within +/- 2 mm, meaning that the system can properly quantify motion asymmetry. Overall, the bias for all symmetry-related results is less than 1 mm, which is important for reproducibility and further comparison to other systems.
引用
收藏
页数:35
相关论文
共 93 条
[1]  
AAEP, 1999, GUID VET SERV HORS S
[2]  
Ahmadi A, 2014, IEEE SENSOR, P2211, DOI 10.1109/ICSENS.2014.6985479
[3]   The effect of induced hindlimb lameness on thoracolumbar kinematics during treadmill locomotion [J].
Alvarez, C. B. Gomez ;
Bobbert, M. F. ;
Lamers, L. ;
Johnston, C. ;
Back, W. ;
van Weeren, P. R. .
EQUINE VETERINARY JOURNAL, 2008, 40 (02) :147-152
[4]   Back kinematics of healthy trotting horses during treadmill versus over ground locomotion [J].
Alvarez, C. B. Gomez ;
Rhodin, M. ;
Bystrom, A. ;
Back, W. ;
van Werren, P. R. .
EQUINE VETERINARY JOURNAL, 2009, 41 (03) :297-300
[5]  
[Anonymous], 2004, STRAPDOWN INERTIAL N
[6]   Evidence of bias affecting the interpretation of the results of local anaesthetic nerve blocks when assessing lameness in horses [J].
Arkell, M. ;
Archer, R. M. ;
Guitian, F. J. ;
May, S. A. .
VETERINARY RECORD, 2006, 159 (11) :346-349
[7]  
Back W, 2013, EQUINE LOCOMOTION, V2nd
[8]   Assessment of Foot Kinematics During Steady State Running Using a Foot-Mounted IMU [J].
Bailey, G. P. ;
Harle, R. .
ENGINEERING OF SPORT 10, 2014, 72 :32-37
[9]   Choice of agreement indices for assessing and improving measurement reproducibility in a core laboratory setting [J].
Barnhart, Huiman X. ;
Yow, Eric ;
Crowley, Anna Lisa ;
Daubert, Melissa A. ;
Rabineau, Dawn ;
Bigelow, Robert ;
Pencina, Michael ;
Douglas, Pamela S. .
STATISTICAL METHODS IN MEDICAL RESEARCH, 2016, 25 (06) :2939-2958
[10]   Science in brief: Highlights from the equine abstracts at the Eighth International Conference on Canine and Equine Locomotion [J].
Barstow, A. ;
Persson-Sjodin, E. .
EQUINE VETERINARY JOURNAL, 2016, 48 (06) :673-675