Vascular Access Monitoring and Surveillance: An Update

被引:13
作者
Valliant, Amanda [1 ]
McComb, Kathryn [1 ]
机构
[1] Univ Wisconsin Hosp & Clin, Div Nephrol, Madison, WI 53792 USA
关键词
Vascular access; Monitoring; Surveillance; BLOOD-FLOW SURVEILLANCE; HEMODIALYSIS ACCESS; ARTERIOVENOUS-FISTULA; PERFORMANCE-CHARACTERISTICS; ULTRASOUND DILUTION; VENOUS-PRESSURE; STENOSIS; THROMBOSIS; MORBIDITY; GRAFTS;
D O I
10.1053/j.ackd.2015.06.002
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Vascular access in dialysis patients remains both a critical link to survival and a significant source of morbidity. Currently, the National Kidney Foundation Kidney Disease Outcomes Quality Initiative (NKF-KDOQI) vascular access guidelines recommend routine vascular access monitoring and encourage dedicated surveillance techniques to be used for early detection of access stenosis and prevention of thrombosis. There is a paucity of clear evidence supporting 1 surveillance technique over another. The purpose of this review is to describe the benefits and limitations of various surveillance techniques commonly used in the care of dialysis patients. Further studies in this area will be useful to determine the most appropriate combination of aggressive clinical monitoring and additional surveillance data to strike a balance between graft thrombosis and unnecessary vascular interventions. (C) 2015 by the National Kidney Foundation, Inc. All rights reserved.
引用
收藏
页码:446 / 452
页数:7
相关论文
共 37 条
[1]  
[Anonymous], 2013, USRDS 2013 Annual Data Report: Atlas of Chronic Kidney Disease and End-Stage Renal Disease in the United States
[2]   Accuracy of physical examination in the detection of arteriovenous fistula stenosis [J].
Asif, Arif ;
Leon, Carlos ;
Orozco-Vargas, Luis Carlos ;
Krishnamurthy, Gururaj ;
Choi, Kenneth L. ;
Mercado, Carlos ;
Merrill, Donna ;
Thomas, Ian ;
Salman, Loay ;
Artikov, Shukhrat ;
Bourgoignie, Jacques J. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2007, 2 (06) :1191-1194
[3]   Predicting hemodialysis access failure with color flow Doppler ultrasound [J].
Bay, WH ;
Henry, ML ;
Lazarus, JM ;
Lew, NL ;
Ling, J ;
Lowrie, EG .
AMERICAN JOURNAL OF NEPHROLOGY, 1998, 18 (04) :296-304
[4]   Surveillance of arteriovenous hemodialysis access: A systematic review and meta-analysis [J].
Casey, Edward T. ab ;
Murad, M. Hassan ac ;
Rizvi, Adnan Z. ad ;
Sidawy, Anton N. f ;
McGrath, Martina M. a ;
Elamin, Mohamed B. ;
Flynn, David N. a ;
McCausland, Finnian R. a ;
Vo, Danny H. a ;
El-Zoghby, Ziad ;
Duncan, Audra A. d ;
Tracz, Michal J. ab ;
Erwin, Patricia J. a ;
Montori, Victor M. ae .
JOURNAL OF VASCULAR SURGERY, 2008, 48 :48S-54S
[5]   Value of static venous pressure for predicting arteriovenous graft thrombosis [J].
Dember, LA ;
Holmberg, EF ;
Kaufman, JS .
KIDNEY INTERNATIONAL, 2002, 61 (05) :1899-1904
[6]   Are hemodialysis access flow measurements by ultrasound dilution the standard of care for access surveillance? [J].
Garland, JS ;
Moist, LM ;
Lindsay, RM .
ADVANCES IN RENAL REPLACEMENT THERAPY, 2002, 9 (02) :91-98
[7]   Fistula First Breakthrough Initiative (FFBI): Lessons About Arteriovenous Fistula Prevalence Goals [J].
Howard, Andrew D. ;
Howard, Robin S. ;
Goldstein, Stuart L. ;
Meyer, Klemens B. .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2013, 61 (03) :523-+
[8]   Simulations of the blood flow in the arterio-venous fistula for haemodialysis [J].
Jodko, Daniel ;
Obidowski, Damian ;
Reorowicz, Piotr ;
Jozwik, Krzysztof .
ACTA OF BIOENGINEERING AND BIOMECHANICS, 2014, 16 (01) :69-74
[9]  
Kumbar L, INT J NEPHROL
[10]   Comparison of hemodialysis blood access flow rates using online measurement of conductivity dialysance and ultrasound dilution [J].
Lacson, Eduardo ;
Lazarus, J. Michael ;
Panlitio, Roy ;
Gotch, Frank .
AMERICAN JOURNAL OF KIDNEY DISEASES, 2008, 51 (01) :99-106