VALIDATION OF A FINITE ELEMENT MODEL OF THE MECHANICAL PERFORMANCE OF SURGICAL KNOTS OF VARYING TOPOLOGY

被引:0
作者
Alden, Arz Y. Qwam [1 ,2 ]
Geeslin, Andrew G. [3 ]
Gustafson, Peter A. [4 ]
机构
[1] Western Michigan Univ, Dept Mech & Aerosp Engn, Kalamazoo, MI 49008 USA
[2] Univ Anbar, Engn Coll, Mech Dept, Ramadi, Al Anbar, Iraq
[3] Western Michigan Univ, Homer Stryker MD Sch Med Borgess Orthopaed, Kalamazoo, MI 49008 USA
[4] Western Michigan Univ, Dept Mech & Aerosp Engn, Homer Stryker MD Sch Med, Kalamazoo, MI 49008 USA
来源
PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2018, VOL 3 | 2019年
关键词
ARTHROSCOPIC KNOTS; SLIDING KNOTS; SUTURE; TENDON; SECURITY; REPAIR; STRENGTH; POLYESTER; BEHAVIOR; TENSILE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Knot tying is considered a basic surgical skill, however, there is no consensus on the best technique. Suture breakage and slippage are failure modes during surgical repair and are related to stress concentrations which cannot be easily established with physical testing. Few computational models exist that describe the effect of knot topology on the failure mechanism. The purpose of this study was to implement the finite element method to analyze the mechanical behavior of surgical sutures according to number of throws and to validate the model against experiments. Methods Experiments and models of monofilament and multifilament sutures were conducted. Multiple throw knots were tested to failure in a laboratory setting and with corresponding finite element models. Gross loads were compared when the knot reached a localized material yield stress in the model or when failure occurred in laboratory tests that have the same suture topology. Results The results of laboratory tests and corresponding finite element models of single throw knots were compared and found to be well correlated and consistent with existing literature in strength prediction and failure location. Moreover, single throw knots have reduced failure strengths relative to non-knotted suture approximately by 120 N for both monofilament and multifilament sutures, respectively.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] The Impact of Coronal Configuration of the Proximal Femur on its Mechanical Properties and the Validation of a New Theoretical Model: Finite Element Analysis and Biomechanical Examination
    Zhang, Lijia
    Zhu, Baozhang
    Chen, Liwan
    Wang, Wenqing
    Zhang, Xiaoyong
    Zhang, Jianguo
    ORTHOPAEDIC SURGERY, 2023, 15 (01) : 62 - 69
  • [22] Hydro-mechanical coupling in the periodontal ligament: A porohyperelastic finite element model
    Bergomi, Marzio
    Cugnoni, Joel
    Galli, Matteo
    Botsis, John
    Belser, Urs C.
    Wiskott, H. W. Anselm
    JOURNAL OF BIOMECHANICS, 2011, 44 (01) : 34 - 38
  • [23] Explicit coupled thermo-mechanical finite element model of steel solidification
    Koric, Seid
    Hibbeler, Lance C.
    Thomas, Brian G.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2009, 78 (01) : 1 - 31
  • [24] Development and validation of a weight-bearing finite element model for total knee replacement
    Woiczinski, M.
    Steinbrueck, A.
    Weber, P.
    Mueller, P. E.
    Jansson, V.
    Schroeder, Ch.
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2016, 19 (10) : 1033 - 1045
  • [25] Development and validation of a new finite element human head model: Yet another head model (YEAHM)
    Fernandes, Fabio A. O.
    Tchepel, Dmitri
    Alves de Sousa, Ricardo J.
    Ptak, Mariusz
    ENGINEERING COMPUTATIONS, 2018, 35 (01) : 477 - 496
  • [26] Establishment and Validation of a Computed Tomography-Based Finite Element Model of Lumbar Vertebrae
    Zhang, Lu
    Zhao, Wen-Zhi
    Xia, Xin
    Chen, Bing-Zhi
    2015 INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION AND ARTIFICIAL INTELLIGENCE (CAAI 2015), 2015, : 160 - 166
  • [27] A procedure to convert field sensor data for finite element model inputs and its validation
    Khan, Zafrul H.
    Tarefder, Rafiqul A.
    CONSTRUCTION AND BUILDING MATERIALS, 2019, 212 : 442 - 455
  • [28] Experimental validation of finite element model for proximal composite femur using optical measurements
    Grassi, Lorenzo
    Vaananen, Sami P.
    Yavari, Saber Amin
    Weinans, Harrie
    Jurvelin, Jukka S.
    Zadpoor, Amir A.
    Isaksson, Hanna
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 21 : 86 - 94
  • [29] CFRTP single-lap adhesive bonding and its mechanical performance enhanced by laser surface treatment: Finite element simulation and experimental validation
    Liu, Zhaobing
    Li, Shucheng
    Yu, Yaoyao
    OPTICS AND LASER TECHNOLOGY, 2025, 181
  • [30] 3D Printing Experimental Validation of the Finite Element Analysis of the Maxillofacial Model
    Shu, Jingheng
    Luo, Haotian
    Zhang, Yuanli
    Liu, Zhan
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9