VALIDATION OF A FINITE ELEMENT MODEL OF THE MECHANICAL PERFORMANCE OF SURGICAL KNOTS OF VARYING TOPOLOGY
被引:0
作者:
Alden, Arz Y. Qwam
论文数: 0引用数: 0
h-index: 0
机构:
Western Michigan Univ, Dept Mech & Aerosp Engn, Kalamazoo, MI 49008 USA
Univ Anbar, Engn Coll, Mech Dept, Ramadi, Al Anbar, IraqWestern Michigan Univ, Dept Mech & Aerosp Engn, Kalamazoo, MI 49008 USA
Alden, Arz Y. Qwam
[1
,2
]
Geeslin, Andrew G.
论文数: 0引用数: 0
h-index: 0
机构:
Western Michigan Univ, Homer Stryker MD Sch Med Borgess Orthopaed, Kalamazoo, MI 49008 USAWestern Michigan Univ, Dept Mech & Aerosp Engn, Kalamazoo, MI 49008 USA
Geeslin, Andrew G.
[3
]
Gustafson, Peter A.
论文数: 0引用数: 0
h-index: 0
机构:
Western Michigan Univ, Dept Mech & Aerosp Engn, Homer Stryker MD Sch Med, Kalamazoo, MI 49008 USAWestern Michigan Univ, Dept Mech & Aerosp Engn, Kalamazoo, MI 49008 USA
Gustafson, Peter A.
[4
]
机构:
[1] Western Michigan Univ, Dept Mech & Aerosp Engn, Kalamazoo, MI 49008 USA
Background Knot tying is considered a basic surgical skill, however, there is no consensus on the best technique. Suture breakage and slippage are failure modes during surgical repair and are related to stress concentrations which cannot be easily established with physical testing. Few computational models exist that describe the effect of knot topology on the failure mechanism. The purpose of this study was to implement the finite element method to analyze the mechanical behavior of surgical sutures according to number of throws and to validate the model against experiments. Methods Experiments and models of monofilament and multifilament sutures were conducted. Multiple throw knots were tested to failure in a laboratory setting and with corresponding finite element models. Gross loads were compared when the knot reached a localized material yield stress in the model or when failure occurred in laboratory tests that have the same suture topology. Results The results of laboratory tests and corresponding finite element models of single throw knots were compared and found to be well correlated and consistent with existing literature in strength prediction and failure location. Moreover, single throw knots have reduced failure strengths relative to non-knotted suture approximately by 120 N for both monofilament and multifilament sutures, respectively.
机构:
Chinese Acad Med Sci & Peking Union Med Coll, 4 4 Med Doctor Program, Beijing, Peoples R China
Peiking Union Med Coll Hosp, Dept Orthopaed, 1 Shuaifuyuan Wangfujing Dongcheng Dist, Beijing 100730, Peoples R ChinaChinese Acad Med Sci & Peking Union Med Coll, 4 4 Med Doctor Program, Beijing, Peoples R China
Zhang, Lijia
Zhu, Baozhang
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Naton Med Inst Co Ltd, Beijing, Peoples R ChinaChinese Acad Med Sci & Peking Union Med Coll, 4 4 Med Doctor Program, Beijing, Peoples R China
Zhu, Baozhang
Chen, Liwan
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Naton Med Inst Co Ltd, Beijing, Peoples R ChinaChinese Acad Med Sci & Peking Union Med Coll, 4 4 Med Doctor Program, Beijing, Peoples R China
Chen, Liwan
Wang, Wenqing
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Naton Med Inst Co Ltd, Beijing, Peoples R ChinaChinese Acad Med Sci & Peking Union Med Coll, 4 4 Med Doctor Program, Beijing, Peoples R China
Wang, Wenqing
Zhang, Xiaoyong
论文数: 0引用数: 0
h-index: 0
机构:
Beijing Naton Med Inst Co Ltd, Beijing, Peoples R ChinaChinese Acad Med Sci & Peking Union Med Coll, 4 4 Med Doctor Program, Beijing, Peoples R China
Zhang, Xiaoyong
Zhang, Jianguo
论文数: 0引用数: 0
h-index: 0
机构:
Peiking Union Med Coll Hosp, Dept Orthopaed, 1 Shuaifuyuan Wangfujing Dongcheng Dist, Beijing 100730, Peoples R ChinaChinese Acad Med Sci & Peking Union Med Coll, 4 4 Med Doctor Program, Beijing, Peoples R China
机构:
Sichuan Univ, Key Lab Biomech Engn Sichuan Prov, Chengdu, Peoples R China
Sichuan Univ, Yibin Inst Ind Technol, Yibin Pk, Yibin, Peoples R ChinaSichuan Univ, Key Lab Biomech Engn Sichuan Prov, Chengdu, Peoples R China
Shu, Jingheng
Luo, Haotian
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Key Lab Biomech Engn Sichuan Prov, Chengdu, Peoples R China
Sichuan Univ, Yibin Inst Ind Technol, Yibin Pk, Yibin, Peoples R ChinaSichuan Univ, Key Lab Biomech Engn Sichuan Prov, Chengdu, Peoples R China
Luo, Haotian
Zhang, Yuanli
论文数: 0引用数: 0
h-index: 0
机构:
Chongqing Three Gorges Med Coll, Dept Med Technol, Chongqing, Peoples R ChinaSichuan Univ, Key Lab Biomech Engn Sichuan Prov, Chengdu, Peoples R China
Zhang, Yuanli
Liu, Zhan
论文数: 0引用数: 0
h-index: 0
机构:
Sichuan Univ, Key Lab Biomech Engn Sichuan Prov, Chengdu, Peoples R China
Sichuan Univ, Yibin Inst Ind Technol, Yibin Pk, Yibin, Peoples R ChinaSichuan Univ, Key Lab Biomech Engn Sichuan Prov, Chengdu, Peoples R China