Variability in Absolute Apparent Diffusion Coefficient Values across Different Platforms May Be Substantial: A Multivendor, Multi-institutional Comparison Study

被引:250
作者
Sasaki, Makoto [1 ]
Yamada, Kei [2 ]
Watanabe, Yoshiyuki [3 ]
Matsui, Mieko [4 ]
Ida, Masahiro [5 ]
Fujiwara, Shunrou [1 ]
Shibata, Eri [1 ]
机构
[1] Iwate Med Univ, Adv Med Res Ctr, Morioka, Iwate 0208505, Japan
[2] Kyoto Prefectural Univ Med, Dept Radiol, Kyoto, Japan
[3] Natl Cardiovasc Ctr, Dept Radiol, Osaka, Japan
[4] Nishi Kobe Med Ctr, Dept Radiol, Kobe, Hyogo, Japan
[5] Ebara Hosp, Dept Radiol, Tokyo, Japan
关键词
D O I
10.1148/radiol.2492071681
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether and to what degree absolute apparent diffusion coefficient (ADC) values vary between different imagers, vendors, field strengths, and intraimager conditions. Materials and Methods: Informed consent and institutional review board approval were obtained. Diffusion-weighted (DW) images with nearly identical parameters were obtained at 1.5 and 3.0 T from 12 healthy volunteers at seven institutions by using 10 magnetic resonance (MR) imagers provided by four different vendors. ADC maps were generated from isotropic DW maps, and images with a b value of 0 sec/mm(2) were generated by using in-house software. The mean pixel values for the brain tissues were calculated for evaluating the differences among coil systems, imagers, vendors, and magnetic field strengths. Results: The absolute ADC values of gray and white matter from the same vendor varied substantially: 4%-9% at 1.5 and 3.0 T. With the exception of one vendor, the intervendor variability at 1.5 T was as high as 7%. Moreover, there was substantial intraimager variability, up to 8%, depending on the coil systems in certain imagers. Conclusion: There is significant variability in ADC values depending on the coil systems, imagers, vendors, and field strengths used for MR imaging. The relative ADC values may be more suitable than absolute ADC values for evaluating diffusion abnormalities in patients enrolled in multicenter acute ischemic stroke trials. (c) RSNA, 2008
引用
收藏
页码:624 / 630
页数:7
相关论文
共 23 条
  • [21] Predictors of hemorrhagic transformation after intravenous recombinant tissue plasminogen activator - Prognostic value of the initial apparent diffusion coefficient and diffusion-weighted lesion volume
    Selim, M
    Fink, JN
    Kumar, S
    Caplan, LR
    Horkan, C
    Chen, Y
    Linfante, I
    Schlaug, G
    [J]. STROKE, 2002, 33 (08) : 2047 - 2052
  • [22] In vivo method for correcting transmit/receive nonuniformities with phased array coils
    Wang, JH
    Qiu, ML
    Constable, RT
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (03) : 666 - 674
  • [23] Transient ischemic attacks before ischemic stroke:: Preconditioning the human brain?: A multicenter magnetic resonance imaging study
    Wegener, S
    Gottschalk, B
    Jovanovic, V
    Knab, R
    Fiebach, JB
    Schellinger, PD
    Kucinski, T
    Jungehülsing, GJ
    Brunecker, P
    Müller, B
    Banasik, A
    Amberger, N
    Wernecke, KD
    Siebler, M
    Röther, J
    Villringer, A
    Weih, M
    [J]. STROKE, 2004, 35 (03) : 616 - 621