Respirometry in control of the activated sludge process

被引:99
作者
Spanjers, H
Vanrolleghem, P
Olsson, G
Dold, P
机构
[1] STATE UNIV GHENT,DEPT APPL MATH BIOMETRY & PROC CONTROL,B-9000 GHENT,BELGIUM
[2] LUND INST TECHNOL,DEPT IND ELECT ENGN & AUTOMAT,S-22100 LUND,SWEDEN
[3] MCMASTER UNIV,DEPT CIVIL ENGN,HAMILTON,ON L8S 4L7,CANADA
关键词
activated sludge; control; oxygen uptake rate; respirometer; respirometry; Scientific and Technical Report; sensor;
D O I
10.1016/0273-1223(96)84211-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper summarises progress of the IAWQ Task Group developing the Scientific and Technical Report (STR) on respirometry in control of the activated sludge process. The significance of respirometry in activated sludge systems is explained from a biochemical background. A classification is proposed which includes all respirometric measuring principles described in the literature. The different respiration rates that can be measured are reviewed and some variables that can be deduced from respiration rate are discussed. Some elementary control concepts will be provided that are necessary for the evaluation of respirometry-based control strategies. Finally, a number of respirometry-based control strategies will be classified and discussed. Copyright (C) 1996 IAWQ. Published by Elsevier Science Ltd.
引用
收藏
页码:117 / 126
页数:10
相关论文
empty
未找到相关数据