Probability of survival and failure mode of endodontically treated incisors without ferrule restored with CAD/CAM fiber-reinforced composite (FRC) post-cores

被引:5
作者
Bergamo, Edmara T. P. [1 ]
Lopes, Adolfo C. O. [1 ]
Campos, Tiago M. B. [1 ]
Amorim, Pedro Henrique [1 ]
Costa, Fabio [2 ]
Benalcazar-Jalkh, Ernesto B. [1 ]
de Carvalho, Laura F. [1 ]
Zahoui, Abbas [1 ]
Piza, Mariana M. T. [1 ]
Gutierres, Eliezer [1 ]
Witek, Lukasz [3 ,4 ]
Bonfante, Estevam A. [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Prosthodont & Periodontol, 9-75 Octavio Pinheiro Brizolla, BR-17012901 Bauru, SP, Brazil
[2] DOne 3D, 2625 Jose Adolfo Bianco Molina, BR-14024210 Ribeirao Preto, SP, Brazil
[3] New York Univ, Coll Dent, Dept Biomat, New York, NY 10012 USA
[4] New York Univ, Tandon Scholl Engn, Dept Biomed Engn, Brooklyn, NY USA
基金
巴西圣保罗研究基金会;
关键词
Dental materials; Polymers; Fiber-reinforced composite; Fatigue; FIXED DENTAL PROSTHESES; LOAD-BEARING CAPACITY; OF-THE-LITERATURE; FRACTURE-RESISTANCE; SINGLE CROWNS; BIOMECHANICAL CONSIDERATIONS; TEETH; FATIGUE; RESTORATION; METAL;
D O I
10.1016/j.jmbbm.2022.105519
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: This study evaluated the probability of survival and failure mode of endodontically treated incisors without ferrule restored with CAD/CAM FRC post-cores. Methods: Root canals of bovine incisors were treated, leaving post preparations of similar to 10 mm. Teeth were allocated into three groups: (i) cast metal post-core, (ii) FRC prefabricated post with a direct resin core build-up, and (iii) CAD/CAM FRC post-core. Posts and zirconia crowns were cemented using resin cement. Specimens were subjected to step-stress accelerated-life fatigue testing in water. Use level probability Weibull curves, probability of survival for a mission of 100,000 cycles at 25, 50, and 100 N, Weibull modulus, and characteristic strength were calculated and plotted. Failure mode was examined under a stereomicroscope. Results: Restored incisors demonstrated high probability of survival (93-100%) for missions estimated at 25 and 50 N, irrespective of post-core foundation. At 100 N, incisors restored with metal posts presented significantly higher probability of survival (99%) relative to CAD/CAM posts (79%), whereas FRC groups demonstrated no significant difference. Weibull analysis indicated no significant difference on the Weibull modulus (m = 3.38-5.92). Incisors reconstructed with metal post-cores (431 N) presented significantly higher characteristic strength relative to prefabricated (200 N) and CAD/CAM (202 N) FRC post-cores. While post fracture was the chief failure mode for prefabricated and CAD/CAM FRC post-cores, post and/or root fracture were the main event for metal post-cores. Conclusion: Endodontically treated incisors without ferrule restored with CAD/CAM FRC post-cores presented promising probability of survival for loads compatible with anterior masticatory forces and favorable failure modes.
引用
收藏
页数:10
相关论文
共 56 条
[1]  
Afroz Shaista, 2013, Indian J Dent Res, V24, P93, DOI 10.4103/0970-9290.114959
[2]   Survey of dentists to determine contemporary use of endodontic posts [J].
Ahmed, Sumitha N. ;
Donovan, Terry E. ;
Ghuman, Taneet .
JOURNAL OF PROSTHETIC DENTISTRY, 2017, 117 (05) :642-645
[3]   Stress Distributions for Hybrid Composite Endodontic Post Designs with and without a Ferrule: FEA Study [J].
Ausiello, Pietro ;
Gloria, Antonio ;
Maietta, Saverio ;
Watts, David C. ;
Martorelli, Massimo .
POLYMERS, 2020, 12 (08)
[4]  
Basaran EG, 2013, J PROSTHET DENT, V109, P88, DOI 10.1016/S0022-3913(13)60022-0
[5]   Load-bearing capacity of handmade and computer-aided design-computer-aided manufacturing-fabricated three-unit fixed dental prostheses of particulate filler composite [J].
Basaran, Emine Goncu ;
Ayna, Emrah ;
Vallittu, Pekka K. ;
Lassila, Lippo V. J. .
ACTA ODONTOLOGICA SCANDINAVICA, 2011, 69 (03) :144-150
[6]   Physicochemical and mechanical characterization of a fiber-reinforced composite used as frameworks of implant-supported prostheses [J].
Bergamo, Edmara T. P. ;
Bastos, Tiago M. C. ;
Lopes, Adolfo C. O. ;
Junior, Everardo N. S. de Araujo ;
Coelho, Paulo G. ;
Jalkh, Ernesto B. Benalcazar ;
Zahoui, Abbas ;
Bonfante, Estevam A. .
DENTAL MATERIALS, 2021, 37 (08) :E443-E453
[7]   Retention of zirconia crowns to Ti-base abutments: effect of luting protocol, abutment treatment and autoclave sterilization [J].
Bergamo, Edmara T. P. ;
Zahoui, Abbas ;
Amorin Ikejiri, Larissa Luri ;
Marun, Manoela ;
da Silva, Kimberly Peixoto ;
Coelho, Paulo G. ;
Soares, Simone ;
Bonfante, Estevam A. .
JOURNAL OF PROSTHODONTIC RESEARCH, 2021, 65 (02) :171-175
[8]   Mechanical properties, fracture resistance, and fatigue limits of short fiber reinforced dental composite resin [J].
Bijelic-Donova, Jasmina ;
Garoushi, Sufyan ;
Vallittu, Pekka K. ;
Lassila, Lippo V. J. .
JOURNAL OF PROSTHETIC DENTISTRY, 2016, 115 (01) :95-102
[9]  
Bonfante E A, 2016, Adv Dent Res, V28, P18, DOI 10.1177/0022034515624445
[10]   Digitally Produced Fiber-Reinforced Composite Substructures for Three-Unit Implant-Supported Fixed Dental Prostheses [J].
Bonfante, Estevam A. ;
Suzuki, Marcelo ;
Carvalho, Ricardo M. ;
Hirata, Ronaldo ;
Lubelski, Will ;
Bonfante, Gerson ;
Pegoraro, Thiago A. ;
Coelho, Paulo G. .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2015, 30 (02) :321-329