Diagnostic accuracy of ultrasound in patients with gout: A meta-analysis

被引:47
作者
Lee, Young Ho [1 ]
Song, Gwan Gyu [1 ]
机构
[1] Korea Univ, Coll Med, Med Ctr, Div Rheumatol,Dept Internal Med,Anam Hosp, 73 Inchon Ro, Seoul 02841, South Korea
关键词
Gout; US; Diagnostic accuracy; Meta-analysis; ULTRASONOGRAPHY; CLASSIFICATION; DISEASE; HETEROGENEITY; DEPOSITION; ARTHRITIS; CRITERIA; JOINT; BIAS;
D O I
10.1016/j.semarthrit.2017.09.012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aimed to evaluate the diagnostic performance of ultrasound (US) for patients with gout. Methods: We searched the Medline, Embase, Pubmed, and Cochrane Library databases, and performed a meta-analysis of the diagnostic accuracy of US according to the double contour sign, tophus, snowstorm, or bony erosion in patients with gout. Results: In total, 11 studies including 938 patients with gout, and 788 controls (patients with nongout inflammatory arthritis) were available for the meta-analysis. The pooled sensitivity and specificity of US were 65.1% ([95% confidence interval (CI): 62.0-68.2] and 89.0% (96.6-91.1), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 5.889 (3.365-10.30), 0.359 (0.266-0.485), and 17.61 (11.11-17.92), respectively. The area under the curve of US was 0.858 and the Q* index was 0.789, indicating good diagnostic accuracy. Some between-study heterogeneity was found in the meta-analyses. Meta-regression showed that the sample size, study design, and diagnostic criteria were not sources of heterogeneity, and subgroup meta-analyses did not change the overall diagnostic accuracy. US signs of tophus, snowstorm, or bony erosion besides the double contour sign were not sensitive (54.3%, 30.8%, and 51.6%), but specific (93.2%, 90.6%, and 93.3%) enough as a diagnostic tool. Conclusions: Our meta-analysis of published studies demonstrates that US offers good diagnostic accuracy with high specificity and can play an important role in the diagnosis of gout. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:703 / 709
页数:7
相关论文
共 32 条
[1]   Hyperuricaemia and gout: time for a new staging system? [J].
Dalbeth, Nicola ;
Stamp, Lisa .
ANNALS OF THE RHEUMATIC DISEASES, 2014, 73 (09) :1598-1600
[2]   Sensitivity and specificity of ultrasonographic features of gout in intercritical and chronic phase [J].
Das, Shyamashis ;
Ghosh, Alakendu ;
Ghosh, Parasar ;
Lahiri, Debasish ;
Sinhamahapatra, Pradyot ;
Basu, Kaushik .
INTERNATIONAL JOURNAL OF RHEUMATIC DISEASES, 2017, 20 (07) :887-893
[3]  
Delle Sedie A, 2010, CLIN EXP RHEUMATOL, V28, P147
[4]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188
[5]   Trim and fill: A simple funnel-plot-based method of testing and adjusting for publication bias in meta-analysis [J].
Duval, S ;
Tweedie, R .
BIOMETRICS, 2000, 56 (02) :455-463
[6]   Meta-analysis: Principles and procedures [J].
Egger, M ;
Smith, GD ;
Phillips, AN .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7121) :1533-1537
[7]   Bias in meta-analysis detected by a simple, graphical test [J].
Egger, M ;
Smith, GD ;
Schneider, M ;
Minder, C .
BMJ-BRITISH MEDICAL JOURNAL, 1997, 315 (7109) :629-634
[8]   Hyaline cartilage involvement in patients with gout and calcium pyrophosphate deposition disease. An ultrasound study [J].
Filippucci, E. ;
Riveros, M. Gutierrez ;
Georgescu, D. ;
Salaffi, F. ;
Grassi, W. .
OSTEOARTHRITIS AND CARTILAGE, 2009, 17 (02) :178-181
[9]   Crystal clear - Sonographic assessment of gout and calcium pyrophosphate deposition disease [J].
Grassi, W. ;
Meenagh, G. ;
Pascual, E. ;
Filippucci, E. .
SEMINARS IN ARTHRITIS AND RHEUMATISM, 2006, 36 (03) :197-202
[10]   Quantifying heterogeneity in a meta-analysis [J].
Higgins, JPT ;
Thompson, SG .
STATISTICS IN MEDICINE, 2002, 21 (11) :1539-1558