A comparison of natural- and laboratory-generated dose response curves for quartz optically stimulated luminescence signals from Chinese Loess

被引:155
作者
Chapot, M. S. [1 ]
Roberts, H. M. [1 ]
Duller, G. A. T. [1 ]
Lai, Z. P. [2 ,3 ]
机构
[1] Aberystwyth Univ, Inst Geog & Earth Sci, Aberystwyth SY23 3DB, Dyfed, Wales
[2] Chinese Acad Sci, State Key Lab Cryosphere Sci Cold & Arid Reg Envi, Lanzhou 730000, Peoples R China
[3] Chinese Acad Sci, Engn Res Inst, Lanzhou 730000, Peoples R China
基金
美国国家科学基金会;
关键词
Natural dose response curve; OSL; Loess; Chinese loess plateau; Luochuan; Maximum age range; SINGLE-ALIQUOT; GROWTH-CURVE; SAR PROTOCOL; OSL; CHRONOLOGY; COMPONENTS; FELDSPAR;
D O I
10.1016/j.radmeas.2012.09.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
It has previously been observed that laboratory-generated quartz optically stimulated luminescence (OSL) signals from different samples have similar dose response curves (DRCs) after they are normalized using a test dose. It therefore seems likely that growth of the normalized signal due to natural irradiation of quartz may also follow a general dose response curve. The existence of such a curve is investigated by constructing a natural DRC from the test dose-normalized natural OSL signals of seven samples from the Luochuan section of the Chinese Loess Plateau. The same aliquots are then used to build single aliquot regenerative (SAR) DRCs, making it possible to compare the natural and laboratory constructed curves. Two main differences are observed. Firstly, the laboratory-generated DRCs are best fitted with double saturating exponential functions whereas the natural DRC is equally well fitted with a single saturating function. Secondly, in the laboratory-generated DRCs the normalized OSL signal continues to increase at high laboratory doses (>500 Gy), whereas no growth is seen at these doses in the equivalent natural DRC. These differences between natural- and laboratory-generated DRCs are still apparent even if data are manipulated to isolate the fast component, or if a sensitivity corrected multiple aliquot regenerative (SC-MAR) dose procedure is used. This suggests that the observed differences are not due to the influence of different components or inter-regenerative dose cycle sensitivity changes. The divergence between the natural- and laboratory-generated DRC means that the current maximum limit of quartz OSL dating at the Luochuan section is 150 Gy, as De estimates above this value are likely to be underestimations. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1045 / 1052
页数:8
相关论文
共 35 条
  • [1] Equivalent dose estimation using a single aliquot of polymineral fine grains
    Banerjee, D
    Murray, AS
    Botter-Jensen, L
    Lang, A
    [J]. RADIATION MEASUREMENTS, 2001, 33 (01) : 73 - 94
  • [2] Investigations into the potential effects of pedoturbation on luminescence dating
    Bateman, MD
    Frederick, CD
    Jaiswal, MK
    Singhvi, AK
    [J]. QUATERNARY SCIENCE REVIEWS, 2003, 22 (10-13) : 1169 - 1176
  • [3] Developments in radiation, stimulation and observation facilities in luminescence measurements
    Botter-Jensen, L
    Andersen, CE
    Duller, GAT
    Murray, AS
    [J]. RADIATION MEASUREMENTS, 2003, 37 (4-5) : 535 - 541
  • [4] Luminescence dating of old (>70 ka) Chinese loess:: A comparison of single-aliquot OSL and IRSL techniques
    Buylaert, J. P.
    Vandenberghe, D.
    Murray, A. S.
    Huot, S.
    De Corte, F.
    Van den Haute, P.
    [J]. QUATERNARY GEOCHRONOLOGY, 2007, 2 (1-4) : 9 - 14
  • [5] Choi J., 2006, ANCIENT TL, V24, P9
  • [6] Stacked 2.6-Ma grain size record from the Chinese loess based on five sections and correlation with the deep-sea δ18O record -: art. no. 1033
    Ding, ZL
    Derbyshire, E
    Yang, SL
    Yu, ZW
    Xiong, SF
    Liu, TS
    [J]. PALEOCEANOGRAPHY, 2002, 17 (03): : 5 - 1
  • [7] Distinguishing quartz and feldspar in single grain luminescence measurements
    Duller, GAT
    [J]. RADIATION MEASUREMENTS, 2003, 37 (02) : 161 - 165
  • [8] LATE PLEISTOCENE CHRONOLOGY OF LOESS DEPOSITION NEAR LUOCHUAN, CHINA
    FORMAN, SL
    [J]. QUATERNARY RESEARCH, 1991, 36 (01) : 19 - 28
  • [9] Characterisation of blue-light stimulated luminescence components in different quartz samples: implications for dose measurement
    Jain, M
    Murray, AS
    Botter-Jensen, L
    [J]. RADIATION MEASUREMENTS, 2003, 37 (4-5) : 441 - 449
  • [10] Dose dependence of thermally transferred optically stimulated luminescence signals in quartz
    Kim, J. C.
    Duller, G. A. T.
    Roberts, H. M.
    Wintle, A. G.
    Lee, Y. I.
    Yi, S. B.
    [J]. RADIATION MEASUREMENTS, 2009, 44 (02) : 132 - 143