Comparison of biomechanical behaviour of maxilla following Le Fort I osteotomy with 2-versus 4-plate fixation using 3D-FEA. Part 1: Advancement surgery

被引:31
作者
Atac, M. S. [1 ]
Erkmen, E. [1 ]
Yucel, E. [1 ]
Kurt, A. [2 ]
机构
[1] Gazi Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06510 Ankara, Turkey
[2] Atilim Univ, Dept Mfg Engn, Ankara, Turkey
关键词
3D finite element analysis; Le Fort I osteotomy; advancement surgery; internal fixation;
D O I
10.1016/j.ijom.2008.10.004
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The study aimed to calculate the location and intensity of the maximum stress fields on the fixation plates and surrounding maxilla following Le Fort I osteotomies after advancement procedures using three-dimensional finite element analysis. The models were generated using skull CT scan data. Le Fort I osteotomy Simulations were made and two separate impacted maxillary models were designed. The ADV-2 model has 2 plate fixations bilaterally at the piriform rims, the ADV-4 model has 4 plate fixations at the zygomatic buttresses and piriform rims. The stress fields on bone, plate and screws were computed for each model. Posterior occlusal loads were simulated on one side in the molar-premolar region, in all three directions, reflecting the chewing forces. The increased locations of highest Von Mises stresses on the plates and highest maximum principle stresses on the bones were determined in ADV-2 models especially Under horizontal and oblique loads when compared with ADV-4 models. Evaluation of the highest Von Mises Stress Values and maximum principal stress revealed that oblique load in the ADV-2 model received the highest values. 4-plate fixation following Le Fort I advancement Surgery exerts less stress on the maxillary bones and fixation materials than 2-plate fixation.
引用
收藏
页码:1117 / 1124
页数:8
相关论文
共 21 条
[1]   A biologic model for assessment of osseous strain patterns and plating systems in the human maxilla [J].
Alberts, LR ;
Phillips, KO ;
Tu, HK ;
Stinson, WW ;
Friedman, A .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2003, 61 (01) :79-88
[2]  
Araujo MM, 2001, J ORAL MAXIL SURG, V59, P1034, DOI 10.1053/joms.2001.25832
[3]   Stability of Le Fort I osteotomy with advancement: A comparison of single maxillary surgery and a two-jaw procedure [J].
Bothur, S ;
Blomqvist, JE ;
Isaksson, S .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1998, 56 (09) :1029-1033
[4]   Fixation of bimaxillary osteotomies with resorbable plates and screws: Experience in 20 consecutive cases [J].
Edwards, RC ;
Kiely, KD ;
Eppley, BL .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (03) :271-276
[5]   STABILITY OF LEFORT-I OSTEOTOMY WITH MAXILLARY ADVANCEMENT - A COMPARISON OF COMBINED WIRE FIXATION AND RIGID FIXATION [J].
EGBERT, M ;
HEPWORTH, B ;
MYALL, R ;
WEST, R .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 53 (03) :243-248
[6]   Comparison of different fixation methods following sagittal split ramus osteotomies using three-dimensional finite elements analysis -: Part 1:: advancement surgery posterior loading [J].
Erkmen, E ;
Simsek, B ;
Yücel, E ;
Kurt, A .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2005, 34 (05) :551-558
[7]   Three-dimensional finite element analysis used to compare methods of fixation after sagittal split ramus osteotomy:: setback surgery-posterior loading [J].
Erkmen, E ;
Simsek, B ;
Yücel, E ;
Kurt, A .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2005, 43 (02) :97-104
[8]  
GRAF H, 1974, HELV ODONTOL ACTA, V18, P7
[9]   A biomechanical evaluation of mandibular angle fracture plating techniques [J].
Haug, RH ;
Fattahi, TT ;
Goltz, M .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (10) :1199-1210
[10]   A biomechanical analysis of the orbitozygomatic complex in human cadavers: Examination of load sharing and failure patterns following fixation with titanium and bioresorbable plating systems [J].
Kasrai, L ;
Hearn, T ;
Gur, E ;
Forrest, CR .
JOURNAL OF CRANIOFACIAL SURGERY, 1999, 10 (03) :237-243