Comparison of Electroencephalography and Cerebral Oximetry to Determine the Need for In-Line Arterial Shunting in Patients Undergoing Carotid Endarterectomy

被引:16
作者
Mauermann, William J. [1 ]
Crepeau, Amy Z. [2 ]
Pulido, Juan N. [1 ]
Lynch, James J. [1 ]
Lobbestael, Aaron [4 ]
Oderich, Gustavo S. [3 ]
Worrell, Gregory A. [2 ]
机构
[1] Mayo Clin, Coll Med, Dept Anesthesiol, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Dept Neurol, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Dept Vasc Surg, Rochester, MN 55905 USA
[4] Nonin Med, Plymouth, MN USA
关键词
anesthesia; electroencephalography; cerebral oximetry; shunting; carotid endarterectomy; stroke; noninvasive; regional spectroscopy; NEAR-INFRARED SPECTROSCOPY; STUMP PRESSURE; EEG; ANESTHESIA; OXYGENATION; CRITERION; STENOSIS; ROUTINE;
D O I
10.1053/j.jvca.2013.02.013
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: To compare cerebral near-infrared regional spectroscopy (NIRS) with the 12-lead electroencephalogram for the detection of ischemia during carotid artery clamping for carotid endarterectomy (CEA). Design: Prospective, observational. Setting: Single, tertiary care center. Participants: Ninety patients older than 18 undergoing elective, unilateral CEA. Interventions: In addition to EEG monitoring, all patients underwent continuous blinded NIRS monitoring with sensors placed bilaterally above the supraorbital ridge. Measurements and Main Results: Seventeen patients were excluded, leaving 73 patients available for evaluation. Four patients (5.5%) required shunting based on EEG findings. Changes in cerebral oxygen saturation (rSO(2)) were assessed on the operative side using the average value for the 1 minute prior to cross-clamp and the lowest rSO(2) value the first 5 minutes postclamp. Each 1% absolute decrease and each 1% relative decrease from baseline conferred a 50% increase in the need for shunt placement (OR 1.5; 95% CI (1.03-2.26); p = 0.03 and OR 1.4; 95% CI (1.02-1.81); p = 0.04 respectively). Sensitivity, specificity, and positive and negative predictive values were determined using significant cutoffs of >= 5% absolute change or >= 10% relative change. Positive predictive value was low ( <25%) for both absolute and relative changes. Conclusions: A decrease in rSO(2) during carotid crossclamping for CEA is associated with EEG-determined need for shunting, but the positive predictive value is low. Using the above cutoffs in the current series would have resulted in an increase in the shunt rate by approximately 20% when it was not indicated by EEG. (C) 2013 Elsevier Inc. All rights reserved.
引用
收藏
页码:1253 / 1259
页数:7
相关论文
共 23 条
  • [1] Prospective randomized trial of routine versus selective shunting in carotid endarterectomy based on stump pressure
    AbuRahma, Ali F.
    Stone, Patrick A.
    Hass, Stephen M.
    Dean, L. Scott
    Habib, Joseph
    Keiffer, Tammi
    Emmett, Mary
    [J]. JOURNAL OF VASCULAR SURGERY, 2010, 51 (05) : 1133 - 1138
  • [2] 2011 ASA/ACCF/AHA/AANN/AANS/ACR/ASNR/CNS/SAIP/SCAI/SIR/SNIS/SVM/SVS Guideline on the Management of Patients With Extracranial Carotid and Vertebral Artery Disease: Executive Summary
    Brott, Thomas G.
    Halperin, Jonathan L.
    Abbara, Suhny
    Bacharach, J. Michael
    Barr, John D.
    Bush, Ruth L.
    Cates, Christopher U.
    Creager, Mark A.
    Fowler, Susan B.
    Friday, Gary
    Hertzberg, Vicki S.
    Mciff, E. Bruce
    Moore, Wesley S.
    Panagos, Peter D.
    Riles, Thomas S.
    Rosenwasser, Robert H.
    Taylor, Allen J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 57 (08) : 1002 - 1044
  • [3] Stenting versus Endarterectomy for Treatment of Carotid-Artery Stenosis
    Brott, Thomas G.
    Hobson, Robert W., II
    Howard, George
    Roubin, Gary S.
    Clark, Wayne M.
    Brooks, William
    Mackey, Ariane
    Hill, Michael D.
    Leimgruber, Pierre P.
    Sheffet, Alice J.
    Howard, Virginia J.
    Moore, Wesley S.
    Voeks, Jenifer H.
    Hopkins, L. Nelson
    Cutlip, Donald E.
    Cohen, David J.
    Popma, Jeffrey J.
    Ferguson, Robert D.
    Cohen, Stanley N.
    Blackshear, Joseph L.
    Silver, Frank L.
    Mohr, J. P.
    Lal, Brajesh K.
    Meschia, James F.
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) : 11 - 23
  • [4] Correlation of carotid artery stump pressure and neurologic changes during 474 carotid endarterectomies performed in awake patients
    Calligaro, KD
    Dougherty, MJ
    [J]. JOURNAL OF VASCULAR SURGERY, 2005, 42 (04) : 684 - 689
  • [5] de Letter JAM, 1998, NEUROL RES, V20, pS23
  • [6] Facco E., 1992, Neurophysiologie Clinique, V22, P437, DOI 10.1016/S0987-7053(05)80018-8
  • [7] Cerebral oximetry does not correlate with electroencephalography and somatosensory evoked potentials in determining the need for shunting during carotid endarterectomy
    Friedell, Mark L.
    Clark, Jason M.
    Graham, David A.
    Isley, Michael R.
    Zhang, Xiao-Feng
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 48 (03) : 601 - 606
  • [8] Cerebral Near-Infrared Spectroscopy in Adults: A Work in Progress
    Ghosh, Arnab
    Elwell, Clare
    Smith, Martin
    [J]. ANESTHESIA AND ANALGESIA, 2012, 115 (06) : 1373 - 1383
  • [9] Correlation of Cerebral Oximetry With Internal Carotid Artery Stump Pressures in Carotid Endarterectomy
    Manwaring, Mark L.
    Durham, Christopher A.
    McNally, Michael M.
    Agle, Steven C.
    Parker, Frank M.
    Stoner, Michael C.
    [J]. VASCULAR AND ENDOVASCULAR SURGERY, 2010, 44 (04) : 252 - 256
  • [10] CORRELATION OF REGIONAL CEREBRAL BLOOD-FLOW (RCBF) WITH EEG CHANGES DURING ISOFLURANE ANESTHESIA FOR CAROTID ENDARTERECTOMY - CRITICAL RCBF
    MESSICK, JM
    CASEMENT, B
    SHARBROUGH, FW
    MILDE, LN
    MICHENFELDER, JD
    SUNDT, TM
    [J]. ANESTHESIOLOGY, 1987, 66 (03) : 344 - 349