Measuring the trace elemental composition of size-resolved airborne particles

被引:112
作者
Herner, JD
Green, PG
Kleeman, MJ
机构
[1] Univ Calif Davis, Dept Civil & Environm Engn, Davis, CA 95616 USA
[2] Calif Air Resources Board, Div Res, Sacramento, CA 95812 USA
关键词
D O I
10.1021/es052315q
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new method to measure the trace elemental composition of size-resolved airborne particles that uses acetone extraction followed by ICPMS analysis is compared to three other established methods: copper anode XRF, molybdenum anode XRF, and an ICPMS method that uses HF digestion. The method detection limit (MDL), accuracy, and precision of each method is studied through the analysis of ambient samples collected in California. The MDLs of the new acetone-ICPMS method are similar to MDLs for the established HF-ICPMS method. Both sets of ICPMS MDLs are 1-3 orders of magnitude lower than XRF MDLs for approximately 50 elements other than the light crustal elements such as silicon, sulfur, calcium, and zinc. The accuracy of the acetone-ICPMS method was verified by comparison to measurements made using ion chromatography and the HF-ICPMS method. The acetone-ICPMS analysis method was more precise than the conventional HF-ICPMS method for collocated measurements. Both ICPMS methods were more precise than XRF for most elements. The size distribution of 21 elements contained in ambient particles collected with cascade impactors could be measured with good precision using the new acetone-ICPMS analysis method: lithium, sulfur, potassium, titanium, vanadium, manganese, iron, gallium, germanium, arsenic, selenium, bromine, rubidium, strontium, cadmium tin, antimony, barium, thallium, lead, and bismuth. It is likely that the size distribution of an additional 9 elements could also be measured when concentrations are sufficiently high: phosphorus, molybdenum, niobium, palladium, cesium, europium, holmium, platinum, and uranium. None of the conventional methods were able to measure the size distribution of these elements with acceptable precision under the conditions studied. The new acetone-ICPMS method should provide useful data for the study of the health effects of airborne particles.
引用
收藏
页码:1925 / 1933
页数:9
相关论文
共 22 条
  • [1] High-speed digital photographic study of an inductively coupled plasma during laser ablation: comparison of dried solution aerosols from a microconcentric nebulizer and solid particles from laser ablation
    Aeschliman, DB
    Bajic, SJ
    Baldwin, DP
    Houk, RS
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2003, 18 (09) : 1008 - 1014
  • [2] Sao Paulo aerosol characterization study
    Alonso, CD
    Martins, MHRB
    Romano, J
    Godinho, R
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 1997, 47 (12): : 1297 - 1300
  • [3] Investigation of sources of atmospheric aerosol at a hot spot area in Dhaka, Bangladesh
    Begum, BA
    Biswas, SK
    Kim, E
    Hopke, PK
    Khaliquzzaman, M
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2005, 55 (02) : 227 - 240
  • [4] Source identification and apportionment of fine particulate matter in Houston, TX, using positive matrix factorization
    Buzcu, B
    Fraser, MP
    Kulkarni, P
    Chellam, S
    [J]. ENVIRONMENTAL ENGINEERING SCIENCE, 2003, 20 (06) : 533 - 545
  • [5] Elemental composition of springtime aerosol in Chillan, Chile
    Carvacho, OF
    Trzepla-Nabaglo, K
    Ashbaugh, LL
    Flocchini, RG
    Melín, P
    Celis, J
    [J]. ATMOSPHERIC ENVIRONMENT, 2004, 38 (31) : 5349 - 5352
  • [6] Airborne particulate matter and human health: A review
    Davidson, CI
    Phalen, RF
    Solomon, PA
    [J]. AEROSOL SCIENCE AND TECHNOLOGY, 2005, 39 (08) : 737 - 749
  • [7] SENSITIVITY VERSUS TARGET BACKINGS FOR ELEMENTAL ANALYSIS BY ALPHA EXCITED X-RAY-EMISSION
    FLOCCHINI, RG
    FEENEY, PJ
    SOMMERVILLE, RJ
    CAHILL, TA
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1972, 100 (03): : 397 - +
  • [8] Size and composition distribution of airborne particulate matter in northern California: I-particulate mass, carbon, and water-soluble ions
    Herner, JD
    Aw, J
    Gao, O
    Chang, DP
    Kleeman, MJ
    [J]. JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION, 2005, 55 (01) : 30 - 51
  • [9] High speed photographic study of wet droplets and solid particles in the inductively coupled plasma
    Houk, RS
    Winge, RK
    Chen, XS
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (10) : 1139 - 1148
  • [10] A CYCLONE FOR SIZE-SELECTIVE SAMPLING OF AMBIENT AIR
    JOHN, W
    REISCHL, G
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1980, 30 (08): : 872 - 876