Universal response in liquid chromatography using charged aerosol detection

被引:195
作者
Gorecki, Tadeusz
Lynen, Frederic
Szucs, Roman
Sandra, Pat
机构
[1] Univ Ghent, Pfizer Analyt Res Ctr, B-9000 Ghent, Belgium
[2] Pfizer Ltd, Analyt R&D, Sandwich CT13 9NJ, Kent, England
关键词
D O I
10.1021/ac060078j
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new, empirical approach is introduced to correct for the varying response of aerosol-based detectors with the varying composition of the mobile phase during gradient elution in HPLC. A Corona charged aerosol detector was used in the experiments. The detector is characterized by a nearly universal response at a given, constant mobile-phase composition for sufficiently nonvolatile analytes. A second pump was used to deliver an exactly inverse gradient compared to the analytical HPLC system, and both flows were mixed in a tee piece before introduction to the Corona detector. The approach proposed made it possible to extend the universal response from isocratic to gradient elution conditions in HPLC, vastly improving the usefulness of this detection technique. The constant response of the detector obtained in this way was first demonstrated in flow injection analysis. Very similar calibration curves were obtained for six sulfonamide drugs after mobile-phase compensation. The approach was also applied to gradient elution with excellent results. The data were characterized by good precision ranging from 4% RSD at 10 mg/L to 1.6% RSD at 780 mg/L. The average limit of detection with a 2-mu L injection was 0.5 mg/L, corresponding to 1 ng injected on the column. The approach proposed allows quantification of unknown compounds, e.g., in pharmaceutical mixtures. Measurement of analytes at a relative concentration of 0.05% versus the main component is demonstrated.
引用
收藏
页码:3186 / 3192
页数:7
相关论文
共 13 条
[1]  
[Anonymous], 29 INT S HIGH PERF L
[2]  
[Anonymous], 29 INT S HIGH PERF L
[3]   EVAPORATIVE ANALYZER AS A MASS DETECTOR FOR LIQUID-CHROMATOGRAPHY [J].
CHARLESWORTH, JM .
ANALYTICAL CHEMISTRY, 1978, 50 (11) :1414-1420
[4]   Evaporative light-scattering detection coupled to microcolumn liquid chromatography for the analysis of underivatized amino acids: Sensitivity, linearity of response and comparisons with UV absorbance detection [J].
Cobb, Z ;
Shaw, PN ;
Lloyd, LL ;
Wrench, N ;
Barrett, DA .
JOURNAL OF MICROCOLUMN SEPARATIONS, 2001, 13 (04) :169-175
[6]  
FORD DL, 1966, J OIL COLOUR CHEM AS, V49, P299
[7]   NITROGEN-SPECIFIC LIQUID-CHROMATOGRAPHY DETECTOR BASED ON CHEMILUMINESCENCE - APPLICATION TO THE ANALYSIS OF AMMONIUM NITROGEN IN WASTE-WATER [J].
FUJINARI, EM ;
COURTHAUDON, LO .
JOURNAL OF CHROMATOGRAPHY, 1992, 592 (1-2) :209-214
[8]  
Gamache PH, 2005, LC GC EUR, V18, P345
[9]  
Hooijschuur EWJ, 2000, HRC-J HIGH RES CHROM, V23, P309
[10]   Toward single-calibrant quantification in HPLC. A comparison of three detection strategies: Evaporative light scattering, chemiluminescent nitrogen, and proton NMR [J].
Lane, S ;
Boughtflower, B ;
Mutton, I ;
Paterson, C ;
Farrant, D ;
Taylor, N ;
Blaxill, Z ;
Carmody, C ;
Borman, P .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4354-4365