Advanced multi-contrast Jones matrix optical coherence tomography for Doppler and polarization sensitive imaging

被引:97
作者
Ju, Myeong Jin [1 ,3 ,4 ]
Hong, Young-Joo [1 ,4 ]
Makita, Shuichi [1 ,4 ]
Lim, Yiheng [1 ,4 ]
Kurokawa, Kazuhiro [1 ,4 ]
Duan, Lian [1 ,4 ]
Miura, Masahiro [2 ]
Tang, Shuo [3 ]
Yasuno, Yoshiaki [1 ,4 ]
机构
[1] Univ Tsukuba, Computat Opt Grp, Tsukuba, Ibaraki, Japan
[2] Tokyo Med Univ, Ibaraki Med Ctr, Dept Ophthalmol, Ami, Ibaraki, Japan
[3] Univ British Columbia, Dept Elect & Comp Engn, Vancouver, BC V5Z 1M9, Canada
[4] Computat Opt & Ophthalmol Grp, Tsukuba, Ibaraki, Japan
来源
OPTICS EXPRESS | 2013年 / 21卷 / 16期
基金
日本学术振兴会;
关键词
RETINAL BLOOD-FLOW; NERVE-FIBER LAYER; IN-VIVO; CLINICAL-APPLICATION; HUMAN SKIN; BIREFRINGENCE; TISSUE; EYE; MICROSCOPY; AGE;
D O I
10.1364/OE.21.019412
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
An advanced version of Jones matrix optical coherence tomography (JMT) is demonstrated for Doppler and polarization sensitive imaging of the posterior eye. JMT is capable of providing localized flow tomography by Doppler detection and investigating the birefringence property of tissue through a three-dimensional (3-D) Jones matrix measurement. Owing to an incident polarization multiplexing scheme based on passive optical components, this system is stable, safe in a clinical environment, and cost effective. Since the properties of this version of JMT provide intrinsic compensation for system imperfection, the system is easy to calibrate. Compared with the previous version of JMT, this advanced JMT achieves a sufficiently long depth measurement range for clinical cases of posterior eye disease. Furthermore, a fine spectral shift compensation method based on the cross-correlation of calibration signals was devised for stabilizing the phase of OCT, which enables a high sensitivity Doppler OCT measurement. In addition, a new theory of JMT which integrates the Jones matrix measurement, Doppler measurement, and scattering measurement is presented. This theory enables a sensitivity-enhanced scattering OCT and high-sensitivity Doppler OCT. These new features enable the application of this system to clinical cases. A healthy subject and a geographic atrophy patient were measured in vivo, and simultaneous imaging of choroidal vasculature and birefringence structures are demonstrated. (c) 2013 Optical Society of America
引用
收藏
页码:19412 / 19436
页数:25
相关论文
共 50 条
  • [1] Three-dimensional multi-contrast imaging of in vivo human skin by Jones matrix optical coherence tomography
    Li, En
    Makita, Shuichi
    Hong, Young-Joo
    Kasaragod, Deepa
    Yasuno, Yoshiaki
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03): : 1290 - 1305
  • [2] Multi-Contrast Jones-Matrix Optical Coherence Tomography-The Concept, Principle, Implementation, and Applications
    Yasuno, Yoshiaki
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2023, 29 (04)
  • [3] Parallel detection of Jones-matrix elements in polarization-sensitive optical coherence tomography
    Yamanari, Masahiro
    Uematsu, Sato
    Ishihara, Kenji
    Ikuno, Yasushi
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (05) : 2318 - 2336
  • [4] Supercontinuum source-based multi-contrast optical coherence tomography for rat retina imaging
    Syu, Jia-Pu
    Buddhakosai, Waradee
    Chen, Shih-Jen
    Ke, Chang-Chih
    Chiou, Shih-Hwa
    Kuo, Wen-Chuan
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (12): : 6132 - 6144
  • [5] Passive component based multifunctional Jones matrix swept source optical coherence tomography for Doppler and polarization imaging
    Lim, Yiheng
    Hong, Young-Joo
    Duan, Lian
    Yamanari, Masahiro
    Yasuno, Yoshiaki
    OPTICS LETTERS, 2012, 37 (11) : 1958 - 1960
  • [6] Retinal imaging with polarization-sensitive optical coherence tomography and adaptive optics
    Cense, Barry
    Gao, Weihua
    Brown, Jeffrey M.
    Jones, Steven M.
    Jonnal, Ravi S.
    Mujat, Mircea
    Park, B. Hyle
    de Boer, Johannes F.
    Miller, Donald T.
    OPTICS EXPRESS, 2009, 17 (24): : 21634 - 21651
  • [7] Depth-resolved investigation of multiple optical properties and wrinkle morphology in eye-corner areas with multi-contrast Jones matrix optical coherence tomography
    Yamazaki, Kohei
    Li, En
    Miyazawa, Arata
    Kobayashi, Masaki
    Sayo, Tetsuya
    Makita, Shuichi
    Takahashi, Yoshito
    Yasuno, Yoshiaki
    Sakai, Shingo
    SKIN RESEARCH AND TECHNOLOGY, 2021, 27 (03) : 435 - 443
  • [8] Machine-learning based segmentation of the optic nerve head using multi-contrast Jones matrix optical coherence tomography with semi-automatic training dataset generation
    Kasaragod, Deepa
    Makita, Shuichi
    Hong, Young-Joo
    Yasuno, Yoshiaki
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (07): : 3220 - 3243
  • [9] Birefringence imaging of posterior eye by multi-functional Jones matrix optical coherence tomography
    Sugiyama, Satoshi
    Hong, Young-Joo
    Kasaragod, Deepa
    Makita, Shuichi
    Uematsu, Sato
    Ikuno, Yasushi
    Miura, Masahiro
    Yasuno, Yoshiaki
    BIOMEDICAL OPTICS EXPRESS, 2015, 6 (12): : 4951 - 4974
  • [10] Advanced polarization sensitive analysis in optical coherence tomography
    Wieloszynska, Aleksandra
    Strakowski, Marcin R.
    APPLIED OPTICAL METROLOGY II, 2017, 10373