Optimising fluorescein diacetate sputum smear microscopy for assessing patients with pulmonary tuberculosis

被引:3
|
作者
Datta, Sumona [1 ,2 ,3 ]
Alvarado, Keren [2 ]
Gilman, Robert H. [4 ]
Valencia, Teresa [2 ]
Aparicio, Christian [2 ]
Ramos, Eric S. [2 ]
Montoya, Rosario [2 ,3 ]
Evans, Carlton A. [1 ,2 ,3 ]
机构
[1] Imperial Coll London, Wellcome Trust Ctr Global Hlth Res, Infect Dis & Immun, London, England
[2] Univ Peruana Cayetano Heredia, Lab Res & Dev, IFHAD Innovat Hlth & Dev, Lima, Peru
[3] Asociac Benefica Prisma, IPSYD, Lima, Peru
[4] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Int Hlth, Baltimore, MD USA
来源
PLOS ONE | 2019年 / 14卷 / 04期
基金
美国国家卫生研究院; 英国惠康基金; 比尔及梅琳达.盖茨基金会;
关键词
DIAGNOSIS; INFECTIOUSNESS;
D O I
10.1371/journal.pone.0214131
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Assessing Mycobacterium tuberculosis (TB) viability by fluorescein diacetate (FDA) microscopy can predict TB culture results, treatment response and infectiousness. However, diverse methods have been published. We aimed to optimise FDA microscopy, minimising sputum processing, biohazard and complexity for use in resource-constrained settings. Methods and results Optimization: Patients with smear-positive pulmonary TB before treatment and healthy control participants provided sputa. These were divided into equal aliquots that were tested directly or after NaOH centrifuge-decontamination. Each aliquot was cultured and used to prepare slides (n = 80). FDA microscopy used: 1 or 3 drops of sputum; with/out acid-alcohol wash; with/out phenol sterilization; with 0/30/60 seconds KMnO4 quenching. Control samples all had negative culture and microscopy results. FDA microscopy had higher sensitivity when performed directly (without centrifuge-decontamination) on 1 drop of sputum (P<0.001), because 3 drops obscured microscopy. Acid-alcohol wash and KMnO4 quenching made bacilli easier to identity (P = 0.005). Phenol sterilization did not impair microscopy (P>0.1). Validation: The 2 protocols that performed best in the optimization experiments were reassessed operationally by comparing duplicate slides (n = 412) stained with KMnO4 quenching for 30 versus 60 seconds. FDA microscopy results were similar (P = 0.4) and highly reproducible, with 97% of counts agreeing within +/-1 logarithm. Storage: Smear microscopy slides and aliquots of the sputum from which they were made were stored for 4 weeks. Twice-weekly, paired slides (n = 80) were stained with freshly prepared versus stored FDA and read quantitatively. Storing sputum, microscopy slides or FDA solution at 4 degrees C or room temperature had no effect on FDA microscopy results (all P>0.2). Cost: Material costs for each slide tested by FDA microscopy using reagents purchased locally were USD $0.05 and required the same equipment, time and skills as auramine acid-fast microscopy. Conclusions We recommend a simple, bio-secure protocol for FDA microscopy that provides sensitive and repeatable results without requiring centrifugation.
引用
收藏
页数:24
相关论文
共 50 条
  • [22] TB-SA ANTIBODY TEST FOR DIAGNOSIS AND MONITORING TREATMENT OUTCOME OF SPUTUM SMEAR NEGATIVE PULMONARY TUBERCULOSIS PATIENTS
    Li, Xinxu
    Xu, Hancheng
    Jiang, Shiwen
    Jing, Kuanhe
    Wang, Li
    Liu, Xiaoqiu
    Li, Weibin
    Zhang, Hui
    Wang, Lixia
    SOUTHEAST ASIAN JOURNAL OF TROPICAL MEDICINE AND PUBLIC HEALTH, 2011, 42 (05) : 1147 - 1153
  • [23] Impact of sputum gross appearance and volume on smear positivity of pulmonary tuberculosis: a prospective cohort study
    Yoon, Soon Ho
    Lee, Nyoung Keun
    Yim, Jae Joon
    BMC INFECTIOUS DISEASES, 2012, 12
  • [24] Yield of smear, culture and amplification tests from repeated sputum induction for the diagnosis of pulmonary tuberculosis
    Al Zahrani, K
    Al Jahdali, H
    Poirier, L
    René, P
    Menzies, D
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2001, 5 (09) : 855 - 860
  • [25] Characterization of non-tuberculous mycobacterial pulmonary disease and pulmonary tuberculosis in patients with AFB smear-positive sputum: A retrospective comparative study
    Li, Xiaoming
    Sun, Dezhi
    Liang, Changsheng
    Gu, Wen
    HELIYON, 2024, 10 (17)
  • [26] Same-day Smear Method Compared with Conventional Sputum Method for Diagnosing Pulmonary Tuberculosis
    Ravindra, Adimulam Ganga
    Rajaram, Manju
    Dwivedi, Dharm Prakash
    Mohapatra, Madhusmita Mohanty
    Palanivel, Chinnakali
    Ramakrishnan, Jayalakshmi
    Saka, Vinod Kumar
    CUREUS, 2018, 10 (06):
  • [27] Comparison of sputum induction and bronchoscopy in diagnosis of sputum smear-negative pulmonary tuberculosis: a systemic review and meta-analysis
    Luo, Wen
    Lin, Yihua
    Li, Zhibin
    Wang, Wanyu
    Shi, Yonghong
    BMC PULMONARY MEDICINE, 2020, 20 (01)
  • [28] Comparison of sputum induction and bronchoscopy in diagnosis of sputum smear-negative pulmonary tuberculosis: a systemic review and meta-analysis
    Wen Luo
    Yihua Lin
    Zhibin Li
    Wanyu Wang
    Yonghong Shi
    BMC Pulmonary Medicine, 20
  • [29] Survey of physician use of radiography and sputum smear microscopy for tuberculosis diagnosis and follow-up in Botswana
    Huebner, RE
    Moeti, TL
    Binkin, NJ
    Rumisha, DW
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 1997, 1 (04) : 333 - 338
  • [30] An alternative 1-day smear microscopy protocol for the diagnosis of pulmonary tuberculosis
    Rawat, Jagdish
    Biswas, Debasis
    Sindhwani, Girish
    Masih, Victor
    RESPIROLOGY, 2010, 15 (07) : 1127 - 1130