Optimising fluorescein diacetate sputum smear microscopy for assessing patients with pulmonary tuberculosis

被引:3
|
作者
Datta, Sumona [1 ,2 ,3 ]
Alvarado, Keren [2 ]
Gilman, Robert H. [4 ]
Valencia, Teresa [2 ]
Aparicio, Christian [2 ]
Ramos, Eric S. [2 ]
Montoya, Rosario [2 ,3 ]
Evans, Carlton A. [1 ,2 ,3 ]
机构
[1] Imperial Coll London, Wellcome Trust Ctr Global Hlth Res, Infect Dis & Immun, London, England
[2] Univ Peruana Cayetano Heredia, Lab Res & Dev, IFHAD Innovat Hlth & Dev, Lima, Peru
[3] Asociac Benefica Prisma, IPSYD, Lima, Peru
[4] Johns Hopkins Bloomberg Sch Publ Hlth, Dept Int Hlth, Baltimore, MD USA
来源
PLOS ONE | 2019年 / 14卷 / 04期
基金
美国国家卫生研究院; 英国惠康基金; 比尔及梅琳达.盖茨基金会;
关键词
DIAGNOSIS; INFECTIOUSNESS;
D O I
10.1371/journal.pone.0214131
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Assessing Mycobacterium tuberculosis (TB) viability by fluorescein diacetate (FDA) microscopy can predict TB culture results, treatment response and infectiousness. However, diverse methods have been published. We aimed to optimise FDA microscopy, minimising sputum processing, biohazard and complexity for use in resource-constrained settings. Methods and results Optimization: Patients with smear-positive pulmonary TB before treatment and healthy control participants provided sputa. These were divided into equal aliquots that were tested directly or after NaOH centrifuge-decontamination. Each aliquot was cultured and used to prepare slides (n = 80). FDA microscopy used: 1 or 3 drops of sputum; with/out acid-alcohol wash; with/out phenol sterilization; with 0/30/60 seconds KMnO4 quenching. Control samples all had negative culture and microscopy results. FDA microscopy had higher sensitivity when performed directly (without centrifuge-decontamination) on 1 drop of sputum (P<0.001), because 3 drops obscured microscopy. Acid-alcohol wash and KMnO4 quenching made bacilli easier to identity (P = 0.005). Phenol sterilization did not impair microscopy (P>0.1). Validation: The 2 protocols that performed best in the optimization experiments were reassessed operationally by comparing duplicate slides (n = 412) stained with KMnO4 quenching for 30 versus 60 seconds. FDA microscopy results were similar (P = 0.4) and highly reproducible, with 97% of counts agreeing within +/-1 logarithm. Storage: Smear microscopy slides and aliquots of the sputum from which they were made were stored for 4 weeks. Twice-weekly, paired slides (n = 80) were stained with freshly prepared versus stored FDA and read quantitatively. Storing sputum, microscopy slides or FDA solution at 4 degrees C or room temperature had no effect on FDA microscopy results (all P>0.2). Cost: Material costs for each slide tested by FDA microscopy using reagents purchased locally were USD $0.05 and required the same equipment, time and skills as auramine acid-fast microscopy. Conclusions We recommend a simple, bio-secure protocol for FDA microscopy that provides sensitive and repeatable results without requiring centrifugation.
引用
收藏
页数:24
相关论文
共 50 条
  • [1] Sputum Microscopy With Fluorescein Diacetate Predicts Tuberculosis Infectiousness
    Datta, Sumona
    Sherman, Jonathan M.
    Tovar, Marco A.
    Bravard, Marjory A.
    Valencia, Teresa
    Montoya, Rosario
    Quino, Willi
    D'Arcy, Nikki
    Ramos, Eric S.
    Gilman, Robert H.
    Evans, Carlton A.
    JOURNAL OF INFECTIOUS DISEASES, 2017, 216 (05) : 514 - 524
  • [2] Sputum smear microscopy in tuberculosis: Is it still relevant?
    Desikan, Prabha
    INDIAN JOURNAL OF MEDICAL RESEARCH, 2013, 137 : 442 - 444
  • [3] Evaluation of Fluorescein Diacetate Viability Staining during Treatment Follow-up Examinations of Smear Positive Pulmonary Tuberculosis Patients
    Gaikwad, Ujjwala Nitin
    Das, Padma
    Bhargava, Anudita
    Behera, Ajoy Kumar
    Jagzape, Tushar Bharat
    Chandraker, Sachin
    INTERNATIONAL JOURNAL OF MYCOBACTERIOLOGY, 2025, 14 (01) : 30 - 35
  • [4] Audit of the practice of sputum smear examination for patients with suspected pulmonary tuberculosis in Fiji
    Gounder, Shakti
    Tayler-Smith, Katherine
    Khogali, Mohammed
    Raikabula, Maopa
    Harries, Anthony D.
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2013, 107 (07) : 427 - 431
  • [5] Supervised and induced sputum among patients with smear-negative pulmonary tuberculosis
    Chang, K. C.
    Leung, C. C.
    Yew, W. W.
    Tam, C. M.
    EUROPEAN RESPIRATORY JOURNAL, 2008, 31 (05) : 1085 - 1090
  • [6] Value of third sputum smear for detection of pulmonary tuberculosis in HIV infected patients
    Marjani, Majid
    Tabarsi, Payam
    Baghaei, Parvaneh
    Mansouri, Davoud
    Masjedi, Mohammad Reza
    Velayati, Ali Akbar
    INFECTIOUS DISEASE REPORTS, 2012, 4 (02) : 140 - 141
  • [7] Sensitivity of direct versus concentrated sputum smear microscopy in HIV-infected patients suspected of having pulmonary tuberculosis
    Cattamanchi, Adithya
    Dowdy, David W.
    Davis, J. Lucian
    Worodria, William
    Yoo, Samuel
    Joloba, Moses
    Matovu, John
    Hopewell, Philip C.
    Huang, Laurence
    BMC INFECTIOUS DISEASES, 2009, 9
  • [8] Critical appraisal of current recommendations and practices for tuberculosis sputum smear microscopy
    Gilpin, C.
    Kim, S. J.
    Lumb, R.
    Rieder, H. L.
    Van Deun, A.
    INTERNATIONAL JOURNAL OF TUBERCULOSIS AND LUNG DISEASE, 2007, 11 (09) : 946 - 952
  • [9] Treatment adherence among sputum smear-positive pulmonary tuberculosis patients in mountainous areas in China
    Yao, Song
    Huang, Wen-Hui
    van den Hof, Susan
    Yang, Shu-Min
    Wang, Xiao-Lin
    Chen, Wei
    Fang, Xue-Hui
    Pan, Hai-Feng
    BMC HEALTH SERVICES RESEARCH, 2011, 11
  • [10] Role of fibreoptic bronchoscopy in early diagnosis of sputum smear negative pulmonary tuberculosis
    Kumar, Raj
    Gupta, Nitesh
    EUROPEAN RESPIRATORY JOURNAL, 2014, 44