Ultrasound real-time elastography can predict malignancy in BI-RADS®-US 3 lesions

被引:37
作者
Wojcinski, Sebastian [1 ]
Boehme, Esther [2 ]
Farrokh, Andre [2 ]
Soergel, Philipp [1 ]
Degenhardt, Friedrich [2 ]
Hillemanns, Peter [1 ]
机构
[1] Hannover Med Sch, Dept OB GYN, D-30625 Hannover, Germany
[2] Franziskus Hosp, Dept OB GYN, Bielefeld, Germany
关键词
Sonoelastography; Breast lesions; BI-RADS-US; 3; Diagnostic accuracy; Breast cancer; Breast imaging; BREAST-LESIONS; ELASTICITY; BENIGN; DIFFERENTIATION; STATISTICS; CRITERIA;
D O I
10.1186/1471-2407-13-159
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Lesions of the breast that are classified BI-RADS (R)-US 3 by ultrasound are probably benign and observation is recommended, although malignancy may occasionally occur. In our study, we focus exclusively on BI-RADS (R)-US 3 lesions and hypothesize that sonoelastography as an adjunct to conventional ultrasound can identify a high-risk-group and a low-risk-group within these patients. Methods: A group of 177 breast lesions that were classified BI-RADS (R)-US 3 were additionally examined with real-time sonoelastography. Elastograms were evaluated according to the Tsukuba Elasticity Score. Pretest and posttest probability of disease (POD), sensitivity (SE), specificity (SP), positive (PPV) and negative predictive values (NPV) and likelihood-ratios (LR) were calculated. Furthermore, we analyzed the false-negative and false-positive cases and performed a model calculation to determine how elastography could affect the proceedings in population screening. Results: In our collection of BI-RADS (R)-US 3 cases there were 169 benign and eight malignant lesions. The pretest POD was 4.5% (95% confidence interval (CI): 2.1-9.0). In patients with a suspicious elastogram (high-risk group), the posttest POD was significantly higher (13.2%, p = 0.041) and the positive LR was 3.2 (95% CI: 1.7-5.9). With a benign elastogram (low-risk group), the posttest POD decreased to 2.2%. SE, SP, PPV and NPV for sonoelastography in BI-RADS (R)-US 3 lesions were 62.5% (95% CI: 25.9-89.8), 80.5% (95% CI: 73.5-86.0), 13.2% (95% CI: 5.0-28.9) and 97.8% (95% CI: 93.3-99.4), respectively. Conclusions: Sonoelastography yields additional diagnostic information in the evaluation of BI-RADS (R)-US 3 lesions of the breast. The examiner can identify a low-risk group that can be vigilantly observed and a high-risk group that should receive immediate biopsy due to an elevated breast cancer risk.
引用
收藏
页数:11
相关论文
共 25 条
[1]  
[Anonymous], 2008, World Cancer Report 2008
[2]  
Barr RG, 2011, RAD SOC N AM 2011 SC
[3]   The Utility of the "Bull's-Eye" Artifact on Breast Elasticity Imaging in Reducing Breast Lesion Biopsy Rate [J].
Barr, Richard G. ;
Lackey, Amanda E. .
ULTRASOUND QUARTERLY, 2011, 27 (03) :151-155
[4]  
Ciurea A I, 2011, Ultraschall Med, V32 Suppl 1, pS27, DOI 10.1055/s-0029-1245684
[5]  
Farrokh A, 2010, ULTRASCHALL MED, V31, P13
[6]   Acoustic radiation force imaging sonoelastography for noninvasive staging of liver fibrosis [J].
Fierbinteanu-Braticevici, Carmen ;
Andronescu, Dan ;
Usvat, Radu ;
Cretoiu, Dragos ;
Baicus, Cristian ;
Marinoschi, Gabriela .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (44) :5525-5532
[7]   Sonographic Criteria for the Differentiation of Benign and Malignant Breast Lesions using Real-Time Spatial Compound Imaging in Combination with XRES Adaptive Image Processing [J].
Hahn, M. ;
Roessner, L. ;
Krainick-Strobel, U. ;
Gruber, I. V. ;
Kraemer, B. ;
Gall, C. ;
Siegmann, K. C. ;
Wallwiener, D. ;
Kagan, K. O. .
ULTRASCHALL IN DER MEDIZIN, 2012, 33 (03) :270-274
[8]   The Accuracy of BI-RADS Classification of Breast Ultrasound as a First-Line Imaging Method [J].
Hille, H. ;
Vetter, M. ;
Hackeloeer, B. J. .
ULTRASCHALL IN DER MEDIZIN, 2012, 33 (02) :160-163
[9]  
IARC, 2008, GLOB DAT
[10]   Breast disease: Clinical application of US elastography for diagnosis [J].
Itoh, A ;
Ueno, E ;
Tohno, E ;
Kamma, H ;
Takahashi, H ;
Shiina, T ;
Yamakawa, M ;
Matsumura, T .
RADIOLOGY, 2006, 239 (02) :341-350