Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography

被引:17
|
作者
Shen, Junlin [1 ]
Du, Xiangying [1 ]
Guo, Daode [1 ]
Cao, Lizhen [1 ]
Gao, Yan [1 ]
Bai, Mei [2 ]
Li, Pengyu [1 ]
Liu, Jiabin [1 ]
Li, Kuncheng [1 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing 100053, Peoples R China
[2] Capital Med Univ, Xuanwu Hosp, Dept Biomed Engn, Beijing 100053, Peoples R China
关键词
Iterative reconstruction; Coronary CT angiography; Radiation dose; IMAGE QUALITY; PROTOCOL;
D O I
10.1016/j.ejrad.2012.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the potential of noise-based tube current reduction method with iterative reconstruction to reduce radiation exposure while achieving consistent image quality in coronary CT angiography (CCTA). Materials and methods: 294 patients underwent CCTA on a 64-detector row CT equipped with iterative reconstruction. 102 patients with fixed tube current were assigned to Group 1, which was used to establish noise-based tube current modulation formulas, where tube current was modulated by the noise of test bolus image. 192 patients with noise-based tube current were randomly assigned to Group 2 and Group 3. Filtered back projection was applied for Group 2 and iterative reconstruction for Group 3. Qualitative image quality was assessed with a 5 point score. Image noise, signal intensity, volume CT dose index, and dose-length product were measured. Results: The noise-based tube current modulation formulas were established through regression analysis using image noise measurements in Group 1. Image noise was precisely maintained at the target value of 35.00 HU with small interquartile ranges for Group 2 (34.17-35.08 HU) and Group 3 (34.34-35.03 HU), while it was from 28.41 to 36.49 HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 14% and 41% reduction in effective dose for Group 2 and Group 3 were observed compared with Group 1. Conclusion: Adequate image quality could be maintained at a desired and consistent noise level with overall 14% dose reduction using noise-based tube current reduction method. The use of iterative reconstruction further achieved approximately 40% reduction in effective dose. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [21] Tradeoff between noise reduction and inartificial visualization in a model-based iterative reconstruction algorithm on coronary computed tomography angiography
    Hirata, Kenichiro
    Utsunomiya, Daisuke
    Kidoh, Masafumi
    Funama, Yoshinori
    Oda, Seitaro
    Yuki, Hideaki
    Nagayama, Yasunori
    Iyama, Yuji
    Nakaura, Takeshi
    Sakabe, Daisuke
    Tsujita, Kenichi
    Yamashita, Yasuyuki
    MEDICINE, 2018, 97 (20)
  • [22] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Sonja Gordic
    Lotus Desbiolles
    Martin Sedlmair
    Robert Manka
    André Plass
    Bernhard Schmidt
    Daniela B. Husarik
    Francesco Maisano
    Simon Wildermuth
    Hatem Alkadhi
    Sebastian Leschka
    European Radiology, 2016, 26 : 459 - 468
  • [23] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Gordic, Sonja
    Desbiolles, Lotus
    Sedlmair, Martin
    Manka, Robert
    Plass, Andre
    Schmidt, Bernhard
    Husarik, Daniela B.
    Maisano, Francesco
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 459 - 468
  • [24] Synergistic Radiation Dose Reduction by Combining Automatic Tube Voltage Selection and Iterative Reconstruction
    Wortman, Jeremy R.
    Adduci, Alexander J.
    Sodickson, Aaron D.
    JOURNAL OF THORACIC IMAGING, 2016, 31 (02) : 111 - 118
  • [25] Tube current reduction and iterative image reconstruction for computed tomography myelography
    Paprottka, Karolin J.
    Schultz, Vivian
    Kupfer, Karina
    Beer, Meinrad
    Zimmer, Claus
    Kirschke, Jan S.
    Baum, Thomas
    Sollmann, Nico
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [26] Minimizing the radiation dose in coronary CT angiography using prospective ECG-triggering, low tube voltage and iterative reconstruction technologies
    Muzaffer Saglam
    Ersin Ozturk
    Kemal Kara
    Japanese Journal of Radiology, 2015, 33 : 46 - 47
  • [27] Model-based iterative reconstruction for reduction of radiation dose in abdominopelvic CT: comparison to adaptive statistical iterative reconstruction
    Yasaka, Koichiro
    Katsura, Masaki
    Akahane, Masaaki
    Sato, Jiro
    Matsuda, Izuru
    Ohtomo, Kuni
    SPRINGERPLUS, 2013, 2 : 1 - 9
  • [28] Minimizing the radiation dose in coronary CT angiography using prospective ECG-triggering, low tube voltage and iterative reconstruction technologies
    Saglam, Muzaffer
    Ozturk, Ersin
    Kara, Kemal
    JAPANESE JOURNAL OF RADIOLOGY, 2015, 33 (01) : 46 - 47
  • [29] CT dose reduction using Automatic Exposure Control and iterative reconstruction: A chest paediatric phantoms study
    Greffier, Jol
    Pereira, Fabricio
    Macri, Francesco
    Beregi, Jean-Paul
    Larbi, Ahmed
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (04): : 582 - 589
  • [30] Improved image quality with simultaneously reduced radiation exposure: Knowledge-based iterative model reconstruction algorithms for coronary CT angiography in a clinical setting
    Andre, Florian
    Fortner, Philipp
    Vembar, Mani
    Mueller, Dirk
    Stiller, Wolfram
    Buss, Sebastian J.
    Kauczor, Hans-Ulrich
    Katus, Hugo A.
    Korosoglou, Grigorios
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2017, 11 (03) : 213 - 220