Noise-based tube current reduction method with iterative reconstruction for reduction of radiation exposure in coronary CT angiography

被引:17
|
作者
Shen, Junlin [1 ]
Du, Xiangying [1 ]
Guo, Daode [1 ]
Cao, Lizhen [1 ]
Gao, Yan [1 ]
Bai, Mei [2 ]
Li, Pengyu [1 ]
Liu, Jiabin [1 ]
Li, Kuncheng [1 ]
机构
[1] Capital Med Univ, Xuanwu Hosp, Dept Radiol, Beijing 100053, Peoples R China
[2] Capital Med Univ, Xuanwu Hosp, Dept Biomed Engn, Beijing 100053, Peoples R China
关键词
Iterative reconstruction; Coronary CT angiography; Radiation dose; IMAGE QUALITY; PROTOCOL;
D O I
10.1016/j.ejrad.2012.10.008
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To investigate the potential of noise-based tube current reduction method with iterative reconstruction to reduce radiation exposure while achieving consistent image quality in coronary CT angiography (CCTA). Materials and methods: 294 patients underwent CCTA on a 64-detector row CT equipped with iterative reconstruction. 102 patients with fixed tube current were assigned to Group 1, which was used to establish noise-based tube current modulation formulas, where tube current was modulated by the noise of test bolus image. 192 patients with noise-based tube current were randomly assigned to Group 2 and Group 3. Filtered back projection was applied for Group 2 and iterative reconstruction for Group 3. Qualitative image quality was assessed with a 5 point score. Image noise, signal intensity, volume CT dose index, and dose-length product were measured. Results: The noise-based tube current modulation formulas were established through regression analysis using image noise measurements in Group 1. Image noise was precisely maintained at the target value of 35.00 HU with small interquartile ranges for Group 2 (34.17-35.08 HU) and Group 3 (34.34-35.03 HU), while it was from 28.41 to 36.49 HU for Group 1. All images in the three groups were acceptable for diagnosis. A relative 14% and 41% reduction in effective dose for Group 2 and Group 3 were observed compared with Group 1. Conclusion: Adequate image quality could be maintained at a desired and consistent noise level with overall 14% dose reduction using noise-based tube current reduction method. The use of iterative reconstruction further achieved approximately 40% reduction in effective dose. (c) 2012 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:349 / 355
页数:7
相关论文
共 50 条
  • [1] Prospective ECG-Triggered Coronary CT Angiography: Clinical Value of Noise-Based Tube Current Reduction Method with Iterative Reconstruction
    Shen, Junlin
    Du, Xiangying
    Guo, Daode
    Cao, Lizhen
    Gao, Yan
    Yang, Qi
    Li, Pengyu
    Liu, Jiabin
    Li, Kuncheng
    PLOS ONE, 2013, 8 (05):
  • [2] Estimated Radiation Dose Reduction Using Adaptive Statistical Iterative Reconstruction in Coronary CT Angiography: The ERASIR Study
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 655 - 660
  • [3] Automated attenuation-based selection of tube voltage and tube current for coronary CT angiography: Reduction of radiation exposure versus a BMI-based strategy with an expert investigator
    Layritz, Christian
    Muschiol, Gerd
    Flohr, Thomas
    Bietau, Christian
    Marwan, Mohamed
    Schuhbaeck, Annika
    Schmid, Jasmin
    Ropers, Dieter
    Achenbach, Stephan
    Pflederer, Tobias
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (05) : 303 - 310
  • [4] Radiation Dose Reduction at Coronary Artery Calcium Scoring by Using a Low Tube Current Technique and Hybrid Iterative Reconstruction
    Matsuura, Noriaki
    Urashima, Masaki
    Fukumoto, Wataru
    Sunamori, Hiroshi
    Tatsugami, Fuminari
    Toyota, Naoyuki
    Awai, Kazuo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (01) : 119 - 124
  • [5] Radiation dose reduction in CT coronary angiography
    Shapiro B.P.
    Young P.M.
    Kantor B.
    Choe Y.H.
    McCollough C.H.
    Gerber T.C.
    Current Cardiology Reports, 2010, 12 (1) : 59 - 67
  • [6] Adaptive Iterative Dose Reduction in coronary CT angiography using 320-row CT: Assessment of radiation dose reduction and image quality
    Tomizawa, Nobuo
    Nojo, Takeshi
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (05) : 318 - 324
  • [7] Coronary CT angiography: image quality, diagnostic accuracy, and potential for radiation dose reduction using a novel iterative image reconstruction technique—comparison with traditional filtered back projection
    Antonio Moscariello
    Richard A. P. Takx
    U. Joseph Schoepf
    Matthias Renker
    Peter L. Zwerner
    Terrence X. O’Brien
    Thomas Allmendinger
    Sebastian Vogt
    Bernhard Schmidt
    Giancarlo Savino
    Christian Fink
    Lorenzo Bonomo
    Thomas Henzler
    European Radiology, 2011, 21
  • [8] Radiation Dose Reduction in Paranasal Sinus CT: With Feasibility of Iterative Reconstruction Technique
    Bang, Minseo
    Choi, Seong Hoon
    Park, Jongha
    Kang, Byeong Seong
    Kwon, Woon Jung
    Lee, Tae Hoon
    Nam, Jung Gwon
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2016, 155 (06) : 982 - 987
  • [9] Submillisievert Radiation Dose Coronary CT Angiography: Clinical Impact of the Knowledge-Based Iterative Model Reconstruction
    Iyama, Yuji
    Nakaura, Takeshi
    Kidoh, Masafumi
    Oda, Seitaro
    Utsunomiya, Daisuke
    Sakaino, Naritsugu
    Tokuyasu, Shinichi
    Osakabe, Hirokazu
    Harada, Kazunori
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2016, 23 (11) : 1393 - 1401
  • [10] Adaptive Statistical Iterative Reconstruction: Assessment of Image Noise and Image Quality in Coronary CT Angiography
    Leipsic, Jonathon
    LaBounty, Troy M.
    Heilbron, Brett
    Min, James K.
    Mancini, G. B. John
    Lin, Fay Y.
    Taylor, Carolyn
    Dunning, Allison
    Earls, James P.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (03) : 649 - 654