Vortex Phenomena in Sidewall Aneurysm Hemodynamics: Experiment and Numerical Simulation

被引:44
作者
Le, Trung B. [1 ,2 ]
Troolin, Daniel R. [3 ]
Amatya, Devesh [4 ]
Longmire, Ellen K. [4 ]
Sotiropoulos, Fotis [1 ,2 ]
机构
[1] Univ Minnesota, St Anthony Falls Lab, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Civil Engn, Minneapolis, MN 55455 USA
[3] TSI Inc, Minneapolis, MN USA
[4] Univ Minnesota, Dept Aerosp Engn, Minneapolis, MN 55455 USA
关键词
Computational Fluid Dynamics; Aneurysm number; Vortex flow; Volumetric velocity measurement; CEREBRAL ANEURYSMS; PULSATILE FLOW; INTRACRANIAL ANEURYSM; VELOCITY-MEASUREMENTS; CAROTID BIFURCATION; BOUNDARY METHOD; SHEAR-STRESS; BLOOD-FLOW; MODEL; 3D;
D O I
10.1007/s10439-013-0811-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We carry out high-resolution laboratory experiments and numerical simulations to investigate the dynamics of unsteady vortex formation across the neck of an anatomic in vitro model of an intracranial aneurysm. A transparent acrylic replica of the aneurysm is manufactured and attached to a pulse duplicator system in the laboratory. Time-resolved three-dimensional three-component velocity measurements are obtained inside the aneurysm sac under physiologic pulsatile conditions. High-resolution numerical simulations are also carried out under conditions replicating as closely as possible those of the laboratory experiment. Comparison of the measured and computed flow fields shows very good agreement in terms of instantaneous velocity fields and three-dimensional coherent structures. Both experiments and numerical simulations show that a well-defined vortical structure is formed near the proximal neck at early systole. This vortical structure is advected by the flow across the aneurysm neck and impinges on the distal wall. The results underscore the complexity of aneurysm hemodynamics and point to the need for integrating high-resolution, time-resolved three-dimensional experimental and computational techniques. The current work emphasizes the importance of vortex formation phenomena at aneurysmal necks and reinforces the findings of previous computational work and recent clinical studies pointing to links between flow pulsatility and aneurysm growth and rupture.
引用
收藏
页码:2157 / 2170
页数:14
相关论文
共 44 条
[1]  
[Anonymous], 1988, P SUMM PROGR CTR TUR
[2]   Flow instability and wall shear stress variation in intracranial aneurysms [J].
Baek, H. ;
Jayaraman, M. V. ;
Richardson, P. D. ;
Karniadakis, G. E. .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2010, 7 (47) :967-988
[3]  
Bijari P. B., 2012, J BIOMECH
[4]   Curvilinear immersed boundary method for simulating fluid structure interaction with complex 3D rigid bodies [J].
Borazjani, Iman ;
Ge, Liang ;
Sotiropoulos, Fotis .
JOURNAL OF COMPUTATIONAL PHYSICS, 2008, 227 (16) :7587-7620
[5]  
Boutsianis E., J BIOMECH ENG, V131
[6]   Flow changes caused by the sequential placement of stents across the neck of sidewall cerebral aneurysms [J].
Cantón, G ;
Levy, DI ;
Lasheras, JC ;
Nelson, PK .
JOURNAL OF NEUROSURGERY, 2005, 103 (05) :891-902
[7]   Efficient pipeline for image-based patient-specific analysis of cerebral aneurysm hemodynamics: Technique and sensitivity [J].
Cebral, JR ;
Castro, MA ;
Appanaboyina, S ;
Putman, CM ;
Millan, D ;
Frangi, AF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) :457-467
[8]   Exploring High Frequency Temporal Fluctuations in the Terminal Aneurysm of the Basilar Bifurcation [J].
Ford, Matthew D. ;
Piomelli, Ugo .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2012, 134 (09)
[9]   PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models [J].
Ford, Matthew D. ;
Nikolov, Hristo N. ;
Milner, Jaques S. ;
Lownie, Stephen P. ;
DeMont, Edwin M. ;
Kalata, Wojciech ;
Loth, Francis ;
Holdsworth, David W. ;
Steinman, David A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02)
[10]  
Gallo D., 2012, J BIOMECH