Remote-controlled magnetic pulmonary vein isolation using a new three-dimensional non-fluoroscopic navigation system: A single-centre prospective study

被引:10
作者
Da Costa, Antoine [1 ]
Ben H'Dech, Mouna [1 ]
Romeyer-Bouchard, Cecile [1 ]
Bisch, Laurence [1 ]
Gate-Martinet, Alexis [1 ]
Levallois, Marie [1 ]
Isaaz, Karl [1 ]
机构
[1] Univ St Etienne, Serv Cardiol, Hop Nord, CHU St Etienne, F-42055 St Etienne 2, France
关键词
Atrial fibrillation; X-ray; Pulmonary vein; Remote magnetic navigation; RADIOFREQUENCY CATHETER ABLATION; PAROXYSMAL ATRIAL-FIBRILLATION; RHYTHM MANAGEMENT AFFIRM; OF-CARDIOLOGY FOUNDATION; IRRIGATED-TIP CATHETER; FOLLOW-UP; IMAGE INTEGRATION; INITIAL-EXPERIENCE; RADIATION-EXPOSURE; TASK-FORCE;
D O I
10.1016/j.acvd.2013.04.008
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. - Catheter ablation of atrial fibrillation (AF) focuses on pulmonary vein isolation (PVI), but the procedure is associated with significant X-ray exposure. Few data exist concerning the combination of remote magnetic navigation (RMN) and a new three-dimensional non-fluoroscopic navigation system (Carto (R) 3), which facilitates precise catheter navigation and limits X-ray exposure. Aims. - To assess the efficacy and extent of fluoroscopic exposure associated with the combination of RMN and the Carto 3 system in patients requiring AF ablation. Methods. - Between January and September 2011, catheter ablation was performed remotely using the Carto 3 system in 81 consecutive patients who underwent PVI for symptomatic drug-refractory AF. The radiofrequency generator was set to a fixed power <= 35W. The primary endpoint was wide-area circumferential PVI confirmed by spiral catheter recording during ablation and including additional lesion lines (left atrial roof and coronary sinus defragmentation) or complex fractionated atrial electrograms for persistent AF. Secondary endpoints included procedural data, complications and freedom from atrial tachycardia (AT)/AF. Results. - Mean age was 60 +/- 9 years; 20% were women; 73% had symptomatic paroxysmal AF; 27% had persistent AF. The CHA(2)DS(2)-VASc score was 1.2 +/- 1. Median procedure time was 3.5 +/- 1 hours; median total X-ray exposure time was 13 +/- 7 minutes;. transseptal puncture and catheter positioning took 8 +/- 4 minutes, left atrium electroanatomical reconstruction 1 +/- 4 minutes and catheter ablation 3.5 +/- 5 minutes. Recurrences were AT (n = 3; 3.7%), paroxysmal AF (n = 8; 9.9%) and persistent AF (n = 4; 4.9%); redo ablation was performed in these 15 (19%) patients. After a median follow-up of 15 +/- 6 months and a single procedure, 71% of patients were free of symptoms; 84% remained asymptomatic after two procedures. Conclusions. - RMN with irrigated catheters combined with the Carto 3 system can be effectively performed in patients requiring AF ablation with minimal use of fluoroscopy, but larger randomized studies are warranted. (c) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:423 / 432
页数:10
相关论文
共 44 条
[1]   Morphologic Analysis of Left Atrial Anatomy by Magnetic Resonance Angiography in Patients With Atrial Fibrillation: A Large Single Center Experience [J].
Anselmino, Matteo ;
Blandino, Alessandro ;
Beninati, Serena ;
Rovera, Chiara ;
Boffano, Carlo ;
Belletti, Marco ;
Caponi, Domenico ;
Scaglione, Marco ;
Cesarani, Federico ;
Gaita, Fiorenzo .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (01) :1-7
[2]   2012 American College of Cardiology Foundation/Society for Cardiovascular Angiography and Interventions Expert Consensus Document on Cardiac Catheterization Laboratory Standards Update A Report of the American College of Cardiology Foundation Task Force on Expert Consensus Documents [J].
Bashore, Thomas M. ;
Balter, Stephen ;
Barac, Ana ;
Byrne, John G. ;
Cavendish, Jeffrey J. ;
Chambers, Charles E. ;
Hermiller, James Bernard, Jr. ;
Kinlay, Scott ;
Landzberg, Joel S. ;
Laskey, Warren K. ;
McKay, Charles R. ;
Miller, Julie M. ;
Moliterno, David J. ;
Moore, John W. M. ;
Oliver-McNeil, Sandra M. ;
Popma, Jeffrey J. ;
Tommaso, Carl L. ;
Harrington, Robert A. ;
Bates, Eric R. ;
Bhatt, Deepak L. ;
Bridges, Charles R. ;
Eisenberg, Mark J. ;
Ferrari, Victor A. ;
Fisher, John D. ;
Gardner, Timothy ;
Gentile, Federico ;
Gilson, Michael F. ;
Hlatky, Mark A. ;
Jacobs, Alice K. ;
Kaul, Sanjay ;
Moliterno, David J. ;
Mukherjee, Debabrata ;
Rosenson, Robert S. ;
Weitz, Howard H. ;
Wesley, Deborah J. ;
Holmes, David R., Jr. ;
Lewin, John C. ;
Oetgen, William J. ;
May, Charlene L. ;
Phoubandith, Dawn R. ;
Kharlamova, Tanja ;
Barrett, Erin A. ;
Ronan, Grace ;
Jones, Tiffany .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (24) :2221-2305
[3]   Image integration increases efficacy of paroxysmal atrial fibrillation catheter ablation: results from the CartoMerge™ Italian Registry [J].
Bertaglia, Emanuele ;
Della Bella, Paolo ;
Tondo, Claudio ;
Proclemer, Alessandro ;
Bottoni, Nicola ;
De Ponti, Roberto ;
Landolina, Maurizio ;
Bongiorni, Maria Grazia ;
Coro, Leonardo ;
Stabile, Giuseppe ;
Dello Russo, Antonio ;
Verlato, Roberto ;
Mantica, Massimo ;
Zoppo, Franco .
EUROPACE, 2009, 11 (08) :1004-1010
[4]   Catheter Ablation Utilizing Remote Magnetic Navigation: A Review of Applications and Outcomes [J].
Bradfield, Jason ;
Tung, Roderick ;
Mandapati, Ravi ;
Boyle, Noel G. ;
Shivkumar, Kalyanam .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (08) :1021-1034
[5]   CHARACTERISTICS AND PROGNOSIS OF LONE ATRIAL-FIBRILLATION - 30-YEAR FOLLOW-UP IN THE FRAMINGHAM-STUDY [J].
BRAND, FN ;
ABBOTT, RD ;
KANNEL, WB ;
WOLF, PA .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 254 (24) :3449-3453
[6]   Remote magnetic navigation for atrial fibrillation ablation: is 'As Good as Manual' good enough [J].
Burkhardt, J. David ;
Di Biase, Luigi ;
Natale, Andrea .
EUROPACE, 2011, 13 (01) :5-6
[7]  
Calkins H, 2012, HEART RHYTHM, V9, P632, DOI 10.1016/j.hrthm.2011.12.016
[8]   Ablation of atrial fibrillation: does the addition of three-dimensional magnetic resonance imaging of the left atrium to electroanatomic mapping improve the clinical outcome? [J].
Caponi, Domenico ;
Corleto, Antonella ;
Scaglione, Marco ;
Blandino, Alessandro ;
Biasco, Luigi ;
Cristoforetti, Yvonne ;
Cerrato, Natascia ;
Toso, Elisabetta ;
Morello, Mara ;
Gaita, Fiorenzo .
EUROPACE, 2010, 12 (08) :1098-1104
[9]   Remote-Controlled Magnetic Pulmonary Vein Isolation Using a New Irrigated-Tip Catheter in Patients With Atrial Fibrillation [J].
Chun, K. R. Julian ;
Wissner, Erik ;
Koektuerk, Buelent ;
Konstantinidou, Melanie ;
Schmidt, Boris ;
Zerm, Thomas ;
Metzner, Andreas ;
Tilz, Roland ;
Boczor, Sigrid ;
Fuernkranz, Alexander ;
Ouyang, Feifan ;
Kuck, Karl-Heinz .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2010, 3 (05) :458-464
[10]   Relationships between sinus rhythm, treatment, and survival in the atrial fibrillation follow-up investigation of rhythm management (AFFIRM) study [J].
Corley, SD ;
Epstein, AE ;
DiMarco, JP ;
Domanski, MJ ;
Geller, N ;
Greene, HL ;
Josephson, RA ;
Kellen, JC ;
Klein, RC ;
Krahn, AD ;
Mickel, M ;
Mitchell, LB ;
Nelson, JD ;
Rosenberg, Y ;
Schron, E ;
Shemanski, L ;
Waldo, AL ;
Wyse, DG .
CIRCULATION, 2004, 109 (12) :1509-1513