On the performance and accuracy of 2D navigator pulses

被引:72
作者
Nehrke, K [1 ]
Börnert, P [1 ]
Groen, J [1 ]
Smink, J [1 ]
Böck, JC [1 ]
机构
[1] Humboldt Univ, Fac Med Charite, Dept Radiol, Campus Virchow Clin, D-10098 Berlin, Germany
关键词
motion artifacts; navigator echo; RF pulse; two-dimensional selective excitation; gradient distortion;
D O I
10.1016/S0730-725X(99)00043-0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to investigate and to optimize the performance of two-dimensional spatially selective excitation pulses used for navigator applications on a clinical scanner. The influence of gradient imperfections, off-resonance effects, and incomplete k-space covering on the pencil beam-shaped spatial excitation profile of the 2D RF pulse was studied. The studies involved experiments performed on phantoms and in vivo. In addition, simulations were carried out by numerical integration of the Bloch equations. The accuracy of positioning of the pencil beam was increased by a factor of three by employing a simple correction scheme for the compensation of gradient distortions. The spatial selectivity of the 2D RF pulse was improved by taking sampling density corrections into account. The 2D RF pulse performance was found to be sufficient to monitor the diaphragm motion even at moderate gradient strength. For applications, where a high spatial resolution is required or a less characteristic contrast is present a strong gradient system is recommended, (C) 1999 Elsevier Science Inc.
引用
收藏
页码:1173 / 1181
页数:9
相关论文
共 25 条
[1]   Effects of gradient anisotropy in MRI [J].
Aldefeld, B ;
Börnert, P .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :606-614
[2]   Curved slice imaging [J].
Bornert, P ;
Schaffter, T .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :932-939
[3]  
Bracewell R. N., 1986, FOURIER TRANSFORM IT, V31999
[4]   ADAPTIVE TECHNIQUE FOR HIGH-DEFINITION MR IMAGING OF MOVING STRUCTURES [J].
EHMAN, RL ;
FELMLEE, JP .
RADIOLOGY, 1989, 173 (01) :255-263
[5]   CORRECTING FOR NONUNIFORM K-SPACE SAMPLING IN 2-DIMENSIONAL NMR SELECTIVE EXCITATION [J].
HARDY, CJ ;
CLINE, HE ;
BOTTOMLEY, PA .
JOURNAL OF MAGNETIC RESONANCE, 1990, 87 (03) :639-645
[6]   RAPID NMR CARDIOGRAPHY WITH A HALF-ECHO M-MODE METHOD [J].
HARDY, CJ ;
PEARLMAN, JD ;
MOORE, JR ;
ROEMER, PB ;
CLINE, HE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1991, 15 (05) :868-874
[7]   BROAD-BAND NUCLEAR MAGNETIC-RESONANCE PULSES WITH TWO-DIMENSIONAL SPATIAL SELECTIVITY [J].
HARDY, CJ ;
CLINE, HE .
JOURNAL OF APPLIED PHYSICS, 1989, 66 (04) :1513-1516
[8]   Density compensation functions for spiral MRI [J].
Hoge, RD ;
Kwan, RKS ;
Pike, GB .
MAGNETIC RESONANCE IN MEDICINE, 1997, 38 (01) :117-128
[9]   OPTIMIZED GRADIENT WAVE-FORMS FOR SPIRAL SCANNING [J].
KING, KF ;
FOO, TKF ;
CRAWFORD, CR .
MAGNETIC RESONANCE IN MEDICINE, 1995, 34 (02) :156-160
[10]   Effects of polar sampling in k-space [J].
Lauzon, ML ;
Rutt, BK .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (06) :940-949