A noninvasive head probe that combines near-infrared spectroscopy (NIRS) and electroencephalography (EEG) for simultaneous measurement of neural dynamics and hemodynamics in the brain is presented. It is composed of a compliant expandable mechanism that accommodates a wide range of head size variation and an elastomeric web that maintains uniform sensor contact pressure on the scalp as the mechanism expands and contracts. The design is intended to help maximize optical and electrical coupling and to maintain stability during head movement. Positioning electrodes at the inion, nasion, central, and preauricular fiducial locations mechanically shapes the probe to place 64 NIRS optodes and 65 EEG electrodes following the 10-5 scalp coordinates. The placement accuracy, precision, and scalp pressure uniformity of the sensors are evaluated. A root-mean-squared (RMS) positional precision of 0.89 +/- 0.23 mm, percent arc subdivision RMS accuracy of 0.19 +/- 0.15%, and mean normal force on the scalp of 2.28 +/- 0.88 N at 5 mm displacement were found. Geometric measurements indicate that the probe will accommodate the full range of adult head sizes. The placement accuracy, precision, and uniformity of sensor contact pressure of the proposed head probe are important determinants of data quality in noninvasive brain monitoring with simultaneous NIRS-EEG. (C) 2013 Society of Photo-Optical Instrumentation Engineers (SPIE) [DOI: 10.1117/1.JBO.18.2.027005]
引用
收藏
页数:11
相关论文
共 55 条
[1]  
[Anonymous], 2005, Electric fields of the brain: The neurophysics of eeg
[2]   THE THEORETICAL BASIS FOR THE DETERMINATION OF OPTICAL PATHLENGTHS IN TISSUE - TEMPORAL AND FREQUENCY-ANALYSIS [J].
ARRIDGE, SR ;
COPE, M ;
DELPY, DT .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (07) :1531-1560
[3]   Intracortically distributed neurovascular coupling relationships within and between human somatosensory cortices [J].
Arthurs, O. J. ;
Donovan, T. ;
Spiegelhalter, D. J. ;
Pickard, J. D. ;
Boniface, S. J. .
CEREBRAL CORTEX, 2007, 17 (03) :661-668
[4]   Variability of electrode positions using electrode caps [J].
Atcherson, Samuel R. ;
Gould, Herbert Jay ;
Pousson, Monique A. ;
Prout, Tina M. .
BRAIN TOPOGRAPHY, 2007, 20 (02) :105-111
[5]   CENTILES FOR ADULT HEAD CIRCUMFERENCE [J].
BUSHBY, KMD ;
COLE, T ;
MATTHEWS, JNS ;
GOODSHIP, JA .
ARCHIVES OF DISEASE IN CHILDHOOD, 1992, 67 (10) :1286-1287
[6]   A Novel Anthropometric Chart for Craniofacial Surgery [J].
Christofides, Efthimios Andreas ;
Steinmann, Mark Eugene .
JOURNAL OF CRANIOFACIAL SURGERY, 2010, 21 (02) :352-357
[7]   Cerebral autoregulation in Alzheimer's disease [J].
Claassen, Jurgen A. H. R. ;
Zhang, Rong .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2011, 31 (07) :1572-1577
[8]   Hydrogel-based photonic sensor for a biopotential wearable recording system [J].
Fernandes, Mariana S. ;
Dias, Nuno S. ;
Silva, Alexandre F. ;
Nunes, Jivago S. ;
Lanceros-Mendez, Senentxu ;
Correia, Jose H. ;
Mendes, Paulo M. .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :80-86
[9]   Scalp electrode impedance, infection risk, and EEG data quality [J].
Ferree, TC ;
Luu, P ;
Russell, GS ;
Tucker, DM .
CLINICAL NEUROPHYSIOLOGY, 2001, 112 (03) :536-544
[10]   Coupling between somatosensory evoked potentials and hemodynamic response in the rat [J].
Franceschini, Maria Angela ;
Nissilae, Ilkka ;
Wu, Weicheng ;
Diamond, Solomon G. ;
Bonmassar, Giorgio ;
Boas, David A. .
NEUROIMAGE, 2008, 41 (02) :189-203