Novel Augmentation Technique for Patellar Tendon Repair Improves Strength and Decreases Gap Formation: A Cadaveric Study

被引:24
作者
Black, James C. [1 ]
Ricci, William M. [2 ]
Gardner, Michael J. [3 ]
McAndrew, Christopher M. [2 ]
Agarwalla, Avinesh [2 ]
Wojahn, Robert D. [2 ]
Abar, Orchid [2 ]
Tang, Simon Y. [2 ]
机构
[1] Mercy Springfield, Mercy Orthoped Trauma, 3050 E Riverbluff Blvd, Ozark, MO 65721 USA
[2] Washington Univ, Sch Med, Dept Orthopaed Surg, St Louis, MO USA
[3] Stanford Univ, Dept Orthopaed Surg, Sch Med, Redwood City, CA USA
关键词
PHYSICAL-ACTIVITY; RUPTURE; QUADRICEPS; SUTURE; MUSCLE; MOBILIZATION; DISRUPTIONS; INJURY; MODEL;
D O I
10.1007/s11999-016-5009-7
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Patellar tendon ruptures commonly are repaired using transosseous patellar drill tunnels with modified-Krackow sutures in the patellar tendon. This simple suture technique has been associated with failure rates and poor clinical outcomes in a modest proportion of patients. Failure of this repair technique can result from gap formation during loading or a single catastrophic event. Several augmentation techniques have been described to improve the integrity of the repair, but standardized biomechanical evaluation of repair strength among different techniques is lacking. The purpose of this study was to describe a novel figure-of-eight suture technique to augment traditional fixation and evaluate its biomechanical performance. We hypothesized that the augmentation technique would (1) reduce gap formation during cyclic loading and (2) increase the maximum load to failure. Ten pairs (two male, eight female) of fresh-frozen cadaveric knees free of overt disorders or patellar tendon damage were used (average donor age, 76 years; range, 65-87 years). For each pair, one specimen underwent the standard transosseous tunnel suture repair with a modified-Krackow suture technique and the second underwent the standard repair with our experimental augmentation method. Nine pairs were suitable for testing. Each specimen underwent cyclic loading while continuously measuring gap formation across the repair. At the completion of cyclic loading, load to failure testing was performed. A difference in gap formation and mean load to failure was seen in favor of the augmentation technique. At 250 cycles, a 68% increase in gap formation was seen for the control group (control: 5.96 +/- 0.86 mm [95% CI, 5.30-6.62 mm]; augmentation: 3.55 +/- 0.56 mm [95% CI, 3.12-3.98 mm]; p = 0.02). The mean load to failure was 13% greater in the augmentation group (control: 899.57 +/- 96.94 N [95% CI, 825.06-974.09 N]; augmentation: 1030.70 +/- 122.41 N [95% CI, 936.61-1124.79 N]; p = 0.01). This biomechanical study showed improved performance of a novel augmentation technique compared with the standard repair, in terms of reduced gap formation during cyclic loading and increased maximum load to failure. Decreased gap formation and higher load to failure may improve healing potential and minimize failure risk. This study shows a potential biomechanical advantage of the augmentation technique, providing support for future clinical investigations comparing this technique with other repair methods that are in common use such as transosseous suture repair.
引用
收藏
页码:2611 / 2618
页数:8
相关论文
共 41 条
[1]   Traumatic patella tendon rupture: early mobilisation following surgical repair [J].
Bhargava, SP ;
Hynes, MC ;
Dowell, JK .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2004, 35 (01) :76-79
[2]   Extensor tendon ruptures after total knee arthroplasty [J].
Bonnin, M. ;
Lustig, S. ;
Huten, D. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) :S21-S31
[3]   The use of suture anchors in repair of the ruptured patellar tendon - A biomechanical study [J].
Bushnell, Brandon D. ;
Byram, Ian R. ;
Weinhold, Paul S. ;
Creighton, R. Alex .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2006, 34 (09) :1492-1499
[4]  
Clayton RA, INJURY, V39, P1338
[5]  
Dempster WT., 1961, Biomechanical Studies of the Musculo-Skeletal System, P81
[6]  
Enad J G, 2001, J South Orthop Assoc, V10, P17
[7]   Biomechanical Properties of Suture Anchor Repair Compared With Transosseous Sutures in Patellar Tendon Ruptures A Cadaveric Study [J].
Ettinger, Max ;
Dratzidis, Antonios ;
Hurschler, Christof ;
Brand, Stephan ;
Calliess, Tilman ;
Krettek, Christian ;
Jagodzinski, Michael ;
Petri, Maximilian .
AMERICAN JOURNAL OF SPORTS MEDICINE, 2013, 41 (11) :2540-2544
[8]   The Role of Mechanical Loading in Tendon Development, Maintenance, Injury, and Repair [J].
Galloway, Marc T. ;
Lalley, Andrea L. ;
Shearn, Jason T. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (17) :1620-1628
[9]  
GELBERMAN R H, 1984, Journal of Orthopaedic Research, V2, P39, DOI 10.1002/jor.1100020107
[10]  
GELBERMAN RH, 1980, CLIN ORTHOP RELAT R, P283