Measuring methotrexate polyglutamates in red blood cells: a new LC-MS/MS-based method

被引:69
作者
den Boer, E. [1 ]
Meesters, R. J. W. [2 ]
van Zelst, B. D. [1 ]
Luider, T. M. [3 ]
Hazes, J. M. W. [4 ]
Heil, S. G. [1 ]
de Jonge, R. [1 ,5 ]
机构
[1] Erasmus Univ, Med Ctr Rotterdam, Dept Clin Chem, NL-3015 CE Rotterdam, Netherlands
[2] Univ Los Andes, Dept Chem, Fac Sci, Bogota, Colombia
[3] Erasmus Univ, Med Ctr, Dept Neurol, NL-3015 CE Rotterdam, Netherlands
[4] Erasmus Univ, Med Ctr, Dept Rheumatol, NL-3015 CE Rotterdam, Netherlands
[5] Erasmus MC, Dept Clin Chem, NL-3015 CE Rotterdam, Netherlands
关键词
Methotrexate; Methotrexate polyglutamates; Erythrocytes; Rheumatoid arthritis; JUVENILE IDIOPATHIC ARTHRITIS; FLUORESCENCE POLARIZATION IMMUNOASSAY; TANDEM MASS-SPECTROMETRY; HIGH-DOSE METHOTREXATE; RHEUMATOID-ARTHRITIS; INTRACELLULAR METHOTREXATE; ERYTHROCYTES; ASSOCIATION; VARIABILITY;
D O I
10.1007/s00216-012-6581-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The folate antagonist methotrexate (MTX) is the anchor drug in the treatment of rheumatoid arthritis. The therapeutic effects of MTX are attributed to the intracellular levels of MTX, present in the cell as polyglutamates (MTXPGn). We developed a new liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS)-based assay to separately quantitate MTXPGn in red blood cells using stable-isotope-labelled internal standards. Samples were analyzed by LC-ESI-MS/MS using a Waters Acquity UPLC BEH C18 column with a 5-100% organic gradient of 10 mM ammonium bicarbonate (pH 10) and methanol. The analysis consisted of simple sample preparation and a 6-min run time. Detection was done using a Waters Acquity UPLC coupled to a Waters Quattro Premier XE with electrospray ionization operating in the positive ionization mode. Assay validation was performed following recent Food and Drug Administration guidelines. The method was linear from 1-1,000 nM for all MTXPGn (R (2) > 0.99). The coefficient of variation ranged from 1-4% for intraday precision and 6-15% for interday precision. Samples were stable for at least 1 month at -80 A degrees C. Recovery ranged from 98-100%, and the relative matrix-effect varied from 95-99%. The lower limit of quantitation was 1 nM for each MTXPGn. Fifty patient samples from the tREACH study were analyzed. The MTXPGn concentration and distribution of these samples were comparable with values reported in literature. The developed LC-ESI-MS/MS method for the quantitative measurement of MTXPGn in red blood cells is both sensitive and precise within the clinically relevant range. The method can be easily applied in clinical laboratories due to the combination of simple pre-treatment with robust LC-ESI-MS/MS.
引用
收藏
页码:1673 / 1681
页数:9
相关论文
共 26 条
[11]   Pharmacogenetic and metabolite measurements are associated with clinical status in patients with rheumatoid arthritis treated with methotrexate: results of a multicentred cross sectional observational study [J].
Dervieux, T ;
Furst, D ;
Lein, DO ;
Capps, R ;
Smith, K ;
Caldwell, J ;
Kremer, J .
ANNALS OF THE RHEUMATIC DISEASES, 2005, 64 (08) :1180-1185
[12]   HPLC determination of erythrocyte methotrexate polyglutamates after low-dose methotrexate therapy in patients with rheumatoid arthritis [J].
Dervieux, T ;
Lein, DO ;
Marcelletti, J ;
Pischel, K ;
Smith, K ;
Walsh, M ;
Richerson, R .
CLINICAL CHEMISTRY, 2003, 49 (10) :1632-1641
[13]   Pharmacogenomic and metabolic biomarkers in the folate pathway and their association with methotrexate effects during dosage escalation in rheumatoid arthritis [J].
Dervieux, Thierry ;
Greenstein, Neal ;
Kremer, Joel .
ARTHRITIS AND RHEUMATISM, 2006, 54 (10) :3095-3103
[14]   Application of fluorescence polarization immunoassay for determination of methotrexate-polyglutamates in rheumatoid arthritis patients [J].
Hayashi, Hideki ;
Fujimaki, Chihiro ;
Tsuboi, Seiji ;
Matsuyama, Taiji ;
Daimon, Takashi ;
Itoh, Kunihiko .
TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2008, 215 (01) :95-101
[15]   An Improved High-performance Liquid Chromatography Method for Quantification of Methotrexate Polyglutamates in Red Blood Cells of Children with Juvenile Idiopathic Arthritis [J].
Hroch, Milos ;
Tukova, Jana ;
Dolezalova, Pavla ;
Chladek, Jaroslav .
BIOPHARMACEUTICS & DRUG DISPOSITION, 2009, 30 (03) :138-148
[16]   Erythrocyte Methotrexate-polyglutamate Assay Using Fluorescence Polarization Immunoassay Technique: Application to the Monitoring of Patients with Rheumatoid Arthritis [J].
Inoue, Sachie ;
Hashiguchi, Masayuki ;
Kawai, Shinichi ;
Mochizuki, Mayumi .
YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 2009, 129 (08) :1001-1005
[17]   SYNTHESIS, RETENTION, AND BIOLOGICAL-ACTIVITY OF METHOTREXATE POLYGLUTAMATES IN CULTURED HUMAN-BREAST CANCER-CELLS [J].
JOLIVET, J ;
SCHILSKY, RL ;
BAILEY, BD ;
DRAKE, JC ;
CHABNER, BA .
JOURNAL OF CLINICAL INVESTIGATION, 1982, 70 (02) :351-360
[18]   Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS [J].
Matuszewski, BK ;
Constanzer, ML ;
Chavez-Eng, CM .
ANALYTICAL CHEMISTRY, 2003, 75 (13) :3019-3030
[19]   Assessment of intracellular methotrexate and methotrexate-polyglutamate metabolite concentrations in erythrocytes by ultrafast matrix-assisted laser desorption/ionization triple quadrupole tandem mass spectrometry [J].
Meesters, Roland J. W. ;
den Boer, Ethan ;
de Jonge, Robert ;
Lindemans, Jan ;
Luider, Theo M. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) :3063-3070
[20]  
NCCLS, 1986, NCCLS, V6