ACCURACY OF REMOVABLE PARTIAL DENTURE METAL FRAMEWORKS FABRICATED BY COMPUTER-AIDED DESIGN/COMPUTER-AIDED MANUFACTURING METHOD: A SYSTEMATIC REVIEW AND META-ANALYSIS

被引:16
作者
Mai, Hai Yen [1 ]
Mai, Hang-Nga [2 ]
Kim, Ho-Jin [3 ]
Lee, Jaesik [4 ]
Lee, Du-Hyeong [1 ,2 ,5 ]
机构
[1] Kyungpook Natl Univ, Sch Dent, Dept Prosthodont, Daegu, South Korea
[2] Kyungpook Natl Univ, Inst Translat Res Dent, Daegu, South Korea
[3] Kyungpook Natl Univ, Sch Dent, Dept Orthodont, Daegu, South Korea
[4] Kyungpook Natl Univ, Sch Dent, Dept Pediat Dent, Daegu, South Korea
[5] Kyungpook Natl Univ, Inst Translat Res Dent, Sch Dent, Dept Prosthodont, 2175 Dalgubeoldaero, Daegu 41940, South Korea
基金
新加坡国家研究基金会;
关键词
Accuracy; Computer aided design; computer aided manufacturing; Metal framework; Removable partial denture; 3D printing; DESIGN; CAD/CAM; CLASPS; PROSTHESES; FIT;
D O I
10.1016/j.jebdp.2021.101681
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective This systematic review and meta-analysis aimed to investigate the accuracy of removable partial denture (RPD) frameworks fabricated by computer-aided de-sign/ computer-aided manufacturing (CAD/CAM) systems compared to frame-works produced by conventional casting methods.Methods A systematic literature search was conducted in electronic databases following the preferred reporting items for systematic reviews and meta-analyses (PRISMA) guidelines, using formulated Boolean operator for searching articles evaluating the fit accuracy of CAD/CAM-fabricated RPD metal frameworks. The agreement of data collection among the reviewers was confirmed using the Cohen kappa coefficient. The modified methodological index for non-randomized studies (MI-NORS) scale was used to assess the quality of the included studies. Heterogene-ity among studies was evaluated, and meta-analyses with global and subgroup analyses were performed.Results A total of 208 articles were identified with 18 articles available for the narrative review and 7 studies available for meta-analysis on the 3D-printed frameworks for RPD (the overall Cohen kappa coefficient = 0.944). There was no article on the accuracy of RPD frameworks made by milling method. The meta-analysis re-vealed that the misfit of frameworks obtained with the CAD/CAM method was significantly higher than that of the conventional lost wax and casting method (SMD = 1.23 gm, 95% CI = 0.3610-2.0981 gm, z = 2.77, P = .0055). Regarding the CAD/CAM techniques used for fabricating RPD metal frameworks, the within subgroup analysis showed that the CAD/CAM-based indirect fabrication method produced frameworks with fit accuracy more similar to the conventional lost-wax and casting method (SMD = 1.15 gm, 95% CI = - 0.06136-2.9192 gm, z = 1.28, P < .01) than the CAD/CAM-based direct fabrication method (SMD = 1.35 gm, 95% CI = -0.2722-2.4381 gm, z = 2.45, P < .01), even though there was no statistical difference between the techniques ( P = .8482).Conclusions The fit accuracy of RPD metal frameworks fabricated by the CAD/CAM method was lower than that of frameworks fabricated by the conventional casting method, but it was within the clinically acceptable range in dimensional misfit. The indirect metal 3D printing technique based on pattern printing and subse-quent casting produced frameworks with fit accuracy more similar to the conven-tional method than the direct fabrication technique.
引用
收藏
页数:11
相关论文
共 46 条
[1]   Direct selective laser sintering of metals [J].
Agarwala, Mukesh ;
Bourell, David ;
Beaman, Joseph ;
Marcus, Harris ;
Barlow, Joel .
RAPID PROTOTYPING JOURNAL, 1995, 1 (01) :26-36
[2]   Patient satisfaction with laser-sintered removable partial dentures: A crossover pilot clinical trial [J].
Almufleh, Balqees ;
Emami, Elham ;
Alageel, Omar ;
de Melo, Fabiana ;
Seng, Francois ;
Caron, Eric ;
Nader, Samer Abi ;
Al-Hashedi, Ashwaq ;
Albuquerque, Rubens ;
Feine, Jocelyne ;
Tamimi, Faleh .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) :560-567
[3]   An analytical model to design circumferential clasps for laser-sintered removable partial dentures [J].
Alsheghri, Ammar A. ;
Alageel, Omar ;
Caron, Eric ;
Ciobanu, Ovidiu ;
Tamimi, Faleh ;
Song, Jun .
DENTAL MATERIALS, 2018, 34 (10) :1474-1482
[4]   Accuracy of CAD-CAM-fabricated removable partial dentures [J].
Arnold, Christin ;
Hey, Jeremias ;
Schweyen, Ramona ;
Setz, Juergen M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (04) :586-592
[5]  
Bajunaid Salwa O, 2019, J Contemp Dent Pract, V20, P476
[6]  
BEAUMONT AJ, 1989, J PROSTHET DENT, V62, P551
[7]   Trial fitting of a removable partial denture framework made using computer-aided design and rapid prototyping techniques [J].
Bibb, R. J. ;
Eggbeer, D. ;
Williams, R. J. ;
Woodward, A. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H7) :793-797
[8]   Rapid manufacture of removable partial denture frameworks [J].
Bibb, Richard ;
Eggbeer, Dominic ;
Williams, Robert .
RAPID PROTOTYPING JOURNAL, 2006, 12 (02) :95-99
[9]  
Bilgin Mehmet Selim, 2016, Eur J Dent, V10, P286, DOI 10.4103/1305-7456.178304
[10]   Restoration of the partially edentulous mouth - A comparison of overdentures, removable partial dentures, fixed partial dentures and implant treatment [J].
BudtzJorgensen, E .
JOURNAL OF DENTISTRY, 1996, 24 (04) :237-244