The Force Attenuation Provided by Hip Protectors Depends on Impact Velocity, Pelvic Size, and Soft Tissue Stiffness

被引:52
作者
Laing, Andrew C. [1 ]
Robinovitch, Stephen N. [1 ,2 ]
机构
[1] Simon Fraser Univ, Sch Kinesiol, Fac Sci Appl, Injury Prevent & Mobil Lab, Burnaby, BC V5A 1S6, Canada
[2] Simon Fraser Univ, Sch Engn Sci, Burnaby, BC V5A 1S6, Canada
来源
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME | 2008年 / 130卷 / 06期
基金
加拿大自然科学与工程研究理事会;
关键词
biomechanics; biomedical measurement; bone; fracture; geriatrics; orthopaedics; prosthetics;
D O I
10.1115/1.2979867
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Wearable hip protectors represent a promising strategy for preventing hip fractures. However, there is lack of agreement on biomechanical testing standards and subsequent uncertainty about the ability of hip protectors to attenuate impact force during a fall. To address this issue, we designed a fall impact simulator that incorporated a "biofidelic" surrogate pelvis, which matched the surface geometry and soft tissue stiffness measured in elderly women (n=15). We then used this system to measure the attenuation in peak femoral neck force provided by two commercially available soft shell protectors (Safehip Soft and Hipsaver) and one rigid shell protector (Safehip Classic). Finally, we examined how the force attenuation provided by each protector was influenced by systematic changes in fall severity (impact velocity), body size (pelvis size), and soft tissue stiffness. With the biofidelic pelvis, the force attenuation averaged over all impact velocities was 27% for Safehip Soft, 17% for Safehip Classic, and 19% for Hipsaver. However, the rank order of hip protectors (and especially the performance of Safehip Classic) varied with the test conditions. Safehip Classic attenuated force by 33% during a low velocity (1 m/s) fall, but only by 8% for a high velocity (4 m/s) fall. In the latter condition, improved attenuation was provided by the soft shell hip protectors (19% by Safehip Soft and 21% by Hipsaver). As soft tissue stiffness increased from softest to most rigid, the attenuation provided by Safehip Classic increased 2.9-fold (from 26% to 76%), while Safehip Soft increased 1.7-fold (from 36% to 60%) and Hipsaver increased 1.1-fold (from 36% to 38%). As pelvis size decreased from largest to smallest, the attenuation provided by Safehip Classic increased 8-fold, but for a high velocity fall and moderate tissue stiffness, never exceeded that provided by Safehip Soft and Hipsaver. Our results indicate that, under biofidelic testing conditions, the soft shell hip protectors we examined generally provided greater force attenuation (averaging up to 27%) than the hard shell protector. Measured values of force attenuation were highly sensitive to variations in impact velocity, pelvic size, and pelvic soft tissue stiffness. This indicates the need to develop international testing standards to guide market approval, the selection of protectors for clinical trials, and the design of improved hip protectors.
引用
收藏
页数:9
相关论文
共 34 条
[1]  
Bouxsein ML, 2007, J BONE MINER RES, V22, P825, DOI [10.1359/jbmr.070309, 10.1359/JBMR.070309]
[2]   Hip protectors in aged-care facilities: a randomized trial of use by individual higher-risk residents [J].
Cameron, ID ;
Venman, J ;
Kurrle, SE ;
Lockwood, K ;
Birks, C ;
Cumming, RG ;
Quine, S ;
Bashford, G .
AGE AND AGEING, 2001, 30 (06) :477-481
[3]  
CAVANAUGH JM, 1990, P 34 STAPP CAR CRASH, P1
[4]   Anatomical hip model for the mechanical testing of hip protectors [J].
Derler, S ;
Spierings, AB ;
Schmitt, KU .
MEDICAL ENGINEERING & PHYSICS, 2005, 27 (06) :475-485
[5]   Reproducibility and side differences of mechanical tests for determining the structural strength of the proximal femur [J].
Eckstein, F ;
Wunderer, C ;
Boehm, H ;
Kuhn, V ;
Priemel, M ;
Link, TM ;
Lochmüller, EM .
JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 (03) :379-385
[6]   Effect of hip fracture on mortality in elderly women:: The EPIDOS prospective study [J].
Empana, JP ;
Dargent-Molina, P ;
Bréart, G .
JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2004, 52 (05) :685-690
[7]   Effects of trochanteric soft tissues and bone density on fracture of the female pelvis in experimental side impacts [J].
Etheridge, BS ;
Beason, DP ;
Lopez, RR ;
Alonso, JE ;
McGwin, G ;
Eberhardt, AW .
ANNALS OF BIOMEDICAL ENGINEERING, 2005, 33 (02) :248-254
[8]   Reducing hip fracture risk during sideways falls: Evidence in young adults of the protective effects of impact to the hands and stepping [J].
Feldman, Fablo ;
Robinovitch, Stephen N. .
JOURNAL OF BIOMECHANICS, 2007, 40 (12) :2612-2618
[9]  
Jaglal SB, 1996, CAN J SURG, V39, P105
[10]   Prevention of hip fracture in elderly people with use of a hip protector. [J].
Kannus, P ;
Parkkari, J ;
Niemi, S ;
Pasanen, M ;
Palvanen, M ;
Järvinen, M ;
Vuori, I .
NEW ENGLAND JOURNAL OF MEDICINE, 2000, 343 (21) :1506-1513