Percutaneous endobiliary forceps biopsy of biliary strictures for histopathologic examination

被引:13
作者
Augustin, Anne Marie [1 ]
Steingrueber, Marcus [1 ]
Fluck, Friederika [1 ]
Goetze, Oliver [2 ]
Bley, Thorsten Alexander [1 ]
Kickuth, Ralph [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Wurzburg, Germany
[2] Univ Hosp Wurzburg, Dept Internal Med 2, Wurzburg, Germany
关键词
FINE-NEEDLE-ASPIRATION; BILE-DUCT; EUS-FNA; OBSTRUCTION; DIAGNOSIS; ERCP; CYTOLOGY; DRAINAGE; BRUSH;
D O I
10.5152/dir.2020.19329
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE We aimed to investigate the feasibility, accuracy and safety of percutaneous endobiliary cholangio-forceps biopsy of biliary strictures in our institution. METHODS A total of 13 percutaneous transhepatic endobiliary biopsies (7 men and 6 women, mean age 66.85 +/- 16.76 years) were performed between January 2015 and March 2019 using a transluminal forceps biopsy device. Technical success, rate of complications, number of biopsy specimens, procedure and fluoroscopy time, mean radiation exposure were evaluated; sensitivity and accuracy were calculated. RESULTS Technical success, i.e., acquisition of at least three (median, 3.00; range, 3-5) macroscopic representative samples, could be achieved in all 13 biopsies. Access was gained via the right liver lobe in 12 of 13 cases (92.3%). All patients presented blood work indicative of cholestasis prior the intervention, with mean bilirubin 4.72 +/- 3.72 mu mol/L, mean gamma-glutamyl transferase 574.16 +/- 360.92 IU/L, and median alkaline phosphatase 407 IU/L (165-1366 IU/L). In 12 of 13 cases (92.3%), biopsied material was sufficient for the pathologist to make a histopathologic diagnosis. Analysis revealed cases of malignancy in eight of 13 cases (61.5%), all of which turned out to be cases of cholangiocarcinoma. In four benign cases (30.8%), diagnosis was considered to be confirmed by further imaging or clinical follow-ups, which showed no signs of progressive disease. There was one case (7.7%) of a false-negative result with proof of malignancy in subsequent surgical tissue extraction. A calculation of diagnostic performance yielded a sensitivity rate of 88.9% and an accuracy rate of 92.3%. There was one case of minor and one case of major complication in our study collective, leading to an overall complication rate of 15.4%. CONCLUSION Percutaneous transhepatic biliary drainage (PTBD)-based forceps biopsy via the transhepatic drainage tract in patients with biliary obstruction of unknown origin is a technically feasible and safe technique with good diagnostic value rates. The procedure should be considered in patients not suitable for endoscopic strategies with indication for establishment of PTBD.
引用
收藏
页码:339 / 344
页数:6
相关论文
共 27 条
  • [1] A PROSPECTIVE COMPARISON OF THE EVALUATION OF BILIARY OBSTRUCTION USING COMPUTED-TOMOGRAPHY AND ULTRASONOGRAPHY
    BARON, RL
    STANLEY, RJ
    LEE, JKT
    KOEHLER, RE
    MELSON, GL
    BALFE, DM
    WEYMAN, PJ
    [J]. RADIOLOGY, 1982, 145 (01) : 91 - 98
  • [2] Fluoroscopic percutaneous brush cytology, forceps biopsy and both in tandem for diagnosis of malignant biliary obstruction
    Boos, Johannes
    Yoo, Raphael J.
    Steinkeler, Jennifer
    Ayata, Gamze
    Ahmed, Muneeb
    Sarwar, Ammar
    Weinstein, Jeffrey
    Faintuch, Salomao
    Brook, Olga R.
    [J]. EUROPEAN RADIOLOGY, 2018, 28 (02) : 522 - 529
  • [3] DONALD JJ, 1993, CAN ASSOC RADIOL J, V44, P185
  • [4] BRUSH AND FORCEPS BIOPSY OF BILIARY DUCTS VIA PERCUTANEOUS TRANS-HEPATIC CATHETERIZATION
    ELYADERANI, MK
    GABRIELE, OF
    [J]. RADIOLOGY, 1980, 135 (03) : 777 - 778
  • [5] Transhepatic forceps biopsy combined with biliary drainage in obstructive jaundice: safety and accuracy
    Fohlen, Audrey
    Bazille, Celine
    Menahem, Benjamin
    Jegonday, Marc Antoine
    Dupont, Benoit
    Le Pennec, Vincent
    Lubrano, Jean
    Guiu, Boris
    Pelage, Jean Pierre
    [J]. EUROPEAN RADIOLOGY, 2019, 29 (05) : 2426 - 2435
  • [6] REVIEW ARTICLE - PERCUTANEOUS TRANS-HEPATIC BILIARY DRAINAGE - EXPERIENCE WITH 311 PROCEDURES
    GUNTHER, RW
    SCHILD, H
    THELEN, M
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1988, 11 (02) : 65 - 71
  • [7] FINE-NEEDLE ASPIRATION BIOPSY - PANCREATIC AND BILIARY TUMORS
    HALLCRAGGS, MA
    LEES, WR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (02) : 399 - 403
  • [8] Cholangiocarcinoma at the hepatic hilus: Sonographic findings
    Hann, LE
    Greatrex, KV
    Bach, AM
    Fong, YM
    Blumgart, LH
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 168 (04) : 985 - 989
  • [9] EUS-FNA versus ERCP for tissue diagnosis of suspect malignant biliary strictures: a prospective comparative study
    Hourneaux Moura, Diogo Turiani
    Guidamaraes, Eduardo
    de Moura, Hourneaux
    Matuguma, Sergio Eiji
    dos Santos, Marcos Eduardo
    Hourneaux Moura, Eduardo Turiani
    Baracat, Felipe Iankelevich
    Artifon, Everson L. A.
    Cheng, Spencer
    Bernardo, Wanderley Marque
    Chacon, Danielle
    Tanigawa, Ryan
    Jukemura, Jose
    [J]. ENDOSCOPY INTERNATIONAL OPEN, 2018, 6 (06) : E769 - E777
  • [10] Inchingolo R, 2018, ACTA RADIOL