Wear at the taper-trunnion junction of contemporary ceramic-on-ceramic hips shown in a multistation hip simulator

被引:14
|
作者
Bhalekar, Rohan M. [1 ]
Smith, Simon L. [1 ]
Joyce, Thomas J. [1 ]
机构
[1] Newcastle Univ, Sch Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
total hip replacement; ceramic-on-ceramic; hip simulator; taper-trunnion junction; wear; TITANIUM-ALLOY; IN-VITRO; METAL; FAILURE; HEAD; PROSTHESES; UHMWPE; DEBRIS; MICROSEPARATION; BEARINGS;
D O I
10.1002/jbm.b.34213
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ceramic-on-ceramic (CoC) total hip replacements (THR) have a substantially lower wear rate than metal-on-polyethylene (MoP) hips, as shown by hip simulator testing. However, the revision rates of CoC and MoP hips are comparable. To try and explain this discrepancy the wear, at both the bearing surfaces and taper-trunnion interface of 36 mm BIOLOXdelta CoC THRs, mounted on 12/14 titanium (Ti6Al4V) trunnions was investigated using a hip simulator (n = 3) and a dynamically loaded CoC sample in a separate test station. Wear was assessed gravimetrically and surface roughness measurements of the articulating and taper surfaces taken at regular intervals. Scanning electron microscopy, surface roughness, and gravimetric measurements of trunnions was performed. After 5 million cycles, the mean total wear from the ceramic articulating surfaces was 0.25 mm(3) from the hip simulator test, and that from the titanium trunnions was 0.29 mm(3). This metal wear may provide an explanation for adverse reaction to metal debris found in contemporary CoC hip joints. It is therefore vital to consider taper-trunnion wear in preclinical testing of artificial hip joints. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1199-1209, 2019.
引用
收藏
页码:1199 / 1209
页数:11
相关论文
共 35 条
  • [31] Influence of Metallic Deposition on Ceramic Femoral Heads on the Wear Behavior of Artificial Hip Joints: A Simulator Study
    Hembus, Jessica
    Roessler, Lisa
    Jackszis, Mario
    Klinder, Annett
    Bader, Rainer
    Zietz, Carmen
    MATERIALS, 2020, 13 (16)
  • [32] Hip-simulator wear studies of an alumina-matrix composite (AMC) ceramic compared to retrieval studies of AMC balls with 1-7 years follow-up
    Clarke, I. C.
    Green, D. D.
    Williams, P. A.
    Kubo, K.
    Pezzotti, G.
    Lombardi, A.
    Turnbull, A.
    Donaldson, T. K.
    WEAR, 2009, 267 (5-8) : 702 - 709
  • [33] Wear behaviour and wear debris characterization of UHMWPE on alumina ceramic, stainless steel, CoCrMo and Ti6Al4V hip prostheses in a hip joint simulator
    Shibo W.
    Shirong G.
    Hongtao L.
    Huang X.
    Journal of Biomimetics, Biomaterials, and Tissue Engineering, 2010, 7 (01): : 7 - 25
  • [34] Clinical Outcomes and Bearing-Specific Complications Following Fourth-Generation Alumina Ceramic-on-Ceramic Total Hip Arthroplasty: A Single-Surgeon Series of 749 Hips at a Minimum of 5-Year Follow-Up
    Lim, Seung-Jae
    Ryu, Hyung-Gon
    Eun, Hyeon-Jun
    Park, Chan-Woo
    Kwon, Kyeu-Back
    Park, Youn-Soo
    JOURNAL OF ARTHROPLASTY, 2018, 33 (07) : 2182 - +
  • [35] Comparing Ceramic-Metal to Metal-Metal Total Hip Replacements-A Simulator Study of Metal Wear and Ion Release in 32-and 38-mm Bearings
    Ishida, Tsunehito
    Clarke, Ian C.
    Donaldson, Thomas K.
    Shirasu, Hideo
    Shishido, Takaaki
    Yamamoto, Kengo
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2009, 91B (02) : 887 - 896