Wear at the taper-trunnion junction of contemporary ceramic-on-ceramic hips shown in a multistation hip simulator

被引:14
|
作者
Bhalekar, Rohan M. [1 ]
Smith, Simon L. [1 ]
Joyce, Thomas J. [1 ]
机构
[1] Newcastle Univ, Sch Engn, Newcastle Upon Tyne NE1 7RU, Tyne & Wear, England
关键词
total hip replacement; ceramic-on-ceramic; hip simulator; taper-trunnion junction; wear; TITANIUM-ALLOY; IN-VITRO; METAL; FAILURE; HEAD; PROSTHESES; UHMWPE; DEBRIS; MICROSEPARATION; BEARINGS;
D O I
10.1002/jbm.b.34213
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ceramic-on-ceramic (CoC) total hip replacements (THR) have a substantially lower wear rate than metal-on-polyethylene (MoP) hips, as shown by hip simulator testing. However, the revision rates of CoC and MoP hips are comparable. To try and explain this discrepancy the wear, at both the bearing surfaces and taper-trunnion interface of 36 mm BIOLOXdelta CoC THRs, mounted on 12/14 titanium (Ti6Al4V) trunnions was investigated using a hip simulator (n = 3) and a dynamically loaded CoC sample in a separate test station. Wear was assessed gravimetrically and surface roughness measurements of the articulating and taper surfaces taken at regular intervals. Scanning electron microscopy, surface roughness, and gravimetric measurements of trunnions was performed. After 5 million cycles, the mean total wear from the ceramic articulating surfaces was 0.25 mm(3) from the hip simulator test, and that from the titanium trunnions was 0.29 mm(3). This metal wear may provide an explanation for adverse reaction to metal debris found in contemporary CoC hip joints. It is therefore vital to consider taper-trunnion wear in preclinical testing of artificial hip joints. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1199-1209, 2019.
引用
收藏
页码:1199 / 1209
页数:11
相关论文
共 35 条
  • [21] Wear of 36-mm BIOLOX® delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions
    Al-Hajjar, Mazen
    Fisher, John
    Tipper, Joanne L.
    Williams, Sophie
    Jennings, Louise M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H5) : 535 - 542
  • [22] Effect of angular mismatch on tribocorrosion at taper-trunnion junction using a finite element model considering mechanical and chemical wear
    Zhang, Guoxian
    Cui, Wen
    Peng, Xing
    Pu, Jian
    Li, Junyan
    Jin, Zhongmin
    TRIBOLOGY INTERNATIONAL, 2023, 184
  • [23] Ceramic-on-ceramic vs. metal-on-metal in total hip arthroplasty (THA): do 36-mm diameters exhibit comparable wear performance?
    Spinelli, M.
    Affatat, S.
    Corvil, A.
    Viceconti, M.
    MATERIALWISSENSCHAFT UND WERKSTOFFTECHNIK, 2009, 40 (1-2) : 94 - 97
  • [24] Severe Wear and multiple Pseudotumor formation due to revision for ceramic head breakage after ceramic-on-ceramic Total hip arthroplasty: a case report
    Dan Xing
    Chaolei Yang
    Rujun Li
    Yunfei Hou
    Bolong Kou
    Hu Li
    Jianhao Lin
    BMC Musculoskeletal Disorders, 20
  • [25] Investigation of the wear properties of ceramic total hip prostheses made of alumina and zirconia combination: A hip simulator study
    Ueno, M
    Ikeuchi, K
    BIOCERAMICS 15, 2003, 240-2 : 809 - 812
  • [26] Minimum 10-Year Results of Cementless Ceramic-On-Ceramic Total Hip Arthroplasty Performed With Transverse Subtrochanteric Osteotomy in Crowe Type IV Hips
    Caylak, Remzi
    Ors, Cagri
    Togrul, Emre
    JOURNAL OF ARTHROPLASTY, 2021, 36 (10) : 3519 - 3526
  • [27] Incidence of Ceramic Component Fractures in Total Hip Arthroplasty Using Contemporary Ceramic-On-Ceramic Bearings: A Retrospective Study Spanning Two Decades From Two Tertiary Referral Hospitals
    Ko, Young-Seung
    Kang, Sang Yoon
    Kim, Hong Seok
    Park, Jung-Wee
    Lee, Young-Kyun
    Yoo, Jeong Joon
    JOURNAL OF ARTHROPLASTY, 2025, 40 (04) : 1055 - 1061.e3
  • [28] Does a micro-grooved trunnion stem surface finish improve fixation and reduce fretting wear at the taper junction of total hip replacements? A finite element evaluation
    Ashkanfar, Ariyan
    Langton, David J.
    Joyce, Thomas J.
    JOURNAL OF BIOMECHANICS, 2017, 63 : 47 - 54
  • [29] Computer-based motion simulation of total hip prostheses with ceramic-on-ceramic wear couple. Analysis of implant design and orientation as influence parameters
    Bader, R
    Steinhauser, E
    Gradinger, R
    Willmann, G
    Mittelmeier, W
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2002, 140 (03): : 310 - 316
  • [30] Primary Total Hip Arthroplasty With Ceramic-On-Ceramic Articulations: Analysis of a Single-Center Series of 1,083 Hips at a Minimum of 10-Year Follow-Up
    Niu, Erlong
    Fu, Jun
    Li, Hao
    Ni, Ming
    Hao, Libo
    Zhou, Yonggang
    Xu, Chi
    Chen, Jiying
    JOURNAL OF ARTHROPLASTY, 2023, 38 (08) : 1539 - 1544