Optimal reference electrode selection for electric source imaging

被引:14
作者
Gencer, NG
Williamson, SJ
Gueziec, A
Hummel, R
机构
[1] NYU, CTR NEURAL SCI, NEW YORK, NY 10003 USA
[2] NYU, COURANT INST MATH SCI, NEW YORK, NY 10003 USA
来源
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY | 1996年 / 99卷 / 02期
关键词
electroencephalography; singular value decomposition; truncated pseudoinverse; reference electrode selection;
D O I
10.1016/0013-4694(96)95139-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
One goal of recording voltages on the scalp is to form images of electrical sources across the cerebral cortex (electric source imaging). In this study, an objective criterion is introduced for selecting the optimal location for the reference electrode to attain the maximum spatial resolution of the source image, for example as provided here by the truncated singular value decomposition pseudoinverse solution. The head model features a realistic cortex within a 3-shell conductive sphere, and pyramidal cell activity is represented by 9104 normal current elements distributed across the cortical area. On the scalp, 234 electrodes provide the measurements with respect to a chosen reference electrode. The effects of the reference electrode when located at the mastoid, occipital pole, vertex or center of the head are analyzed by a singular value decomposition of the lead field matrices. Sensitivity to noise, and hence the spatial resolution, is found to depend on characteristics of the lead field matrix that are determined by the choice of the image source surface, electrode array and location of the reference electrode. Using a reference close to a source surface increases the sensitivity of the measurement system in identifying the nearby activity of low spatial frequency content. However, this feature is compromised by a reduction in spatial resolution for distant cortical areas due to noise in the measurements. A new performance measure, the image sensitivity map, is introduced to identify the cortical regions that provide peak image sensitivity. This measure may be exploited in designing the geometry of an electrode array and selecting the location of the reference electrode to follow the activity on a specific area of the cortical surface.
引用
收藏
页码:163 / 173
页数:11
相关论文
共 25 条
[1]  
ALBERT A, 1972, REGRESSION MOOREPENR
[2]   EMULATION OF SOMATOSENSORY EVOKED-POTENTIAL (SEP) COMPONENTS WITH THE 3-SHELL HEAD MODEL AND THE PROBLEM OF GHOST POTENTIAL FIELDS WHEN USING AN AVERAGE REFERENCE IN BRAIN MAPPING [J].
DESMEDT, JE ;
CHALKLIN, V ;
TOMBERG, C .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1990, 77 (04) :243-258
[3]   Electrical impedance tomography: Induced-current imaging achieved with a multiple coil system [J].
Gencer, NG ;
Ider, YZ ;
Williamson, SJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (02) :139-149
[4]  
GEORGE JS, 1991, SPIE MED IMAGING 5, V1443, P37
[5]  
Golub G, 2013, Matrix Computations, V4th
[6]   Exploiting triangulated surface extraction using tetrahedral decomposition [J].
Gueziec, A ;
Hummel, R .
IEEE TRANSACTIONS ON VISUALIZATION AND COMPUTER GRAPHICS, 1995, 1 (04) :328-342
[7]  
Gueziec A., 1995, Second Annual International Symposium on Medical Robotics and Computer Assisted Surgery, MRCAS '95, P132
[8]  
GUEZIEC A, 1994, P SOC PHOTO-OPT INS, V2359, P631
[9]   AN OPTIMAL CONSTRAINED LINEAR INVERSE METHOD FOR MAGNETIC SOURCE IMAGING [J].
HUGHETT, P .
ANNALS OF BIOMEDICAL ENGINEERING, 1995, 23 (04) :506-523
[10]   INTERPRETATION OF INACCURATE, INSUFFICIENT AND INCONSISTENT DATA [J].
JACKSON, DD .
GEOPHYSICAL JOURNAL OF THE ROYAL ASTRONOMICAL SOCIETY, 1972, 28 (02) :97-&