The Effects of duct height on heat transfer enhancement of a co-rotating type rectangular finned surface in duct

被引:21
作者
Islam, M. D. [1 ]
Oyakawa, K. [2 ]
Yaga, M. [2 ]
Kubo, I. [1 ]
机构
[1] Petr Inst, Dept Mech Syst Engn, Airport Rd,POB 2533, Abu Dhabi, U Arab Emirates
[2] Univ Ryukyus, Dept Mech Syst Engn, Fac Engn, Okinawa 9030213, Japan
关键词
Convective heat transfer; Duct height; Heat transfer enhancement; Infrared image system; Rectangular fin; PRESSURE-DROP; FLUID-FLOW; ARRAYS; BLOCKS;
D O I
10.1016/j.expthermflusci.2008.10.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
Experiments were performed to investigate the effect of duct height on heat transfer enhancement of a surface affixed with arrays (7 x 7) of short rectangular plate fins of a co-rotating type pattern in the duct. An infrared imaging system is used to measure detailed distributions of the heat transfer at the endwall along with the fin base. An infrared camera of TVS 8000 with 160 x 120 point In-Sb sensor was used to measure the temperature distributions in order to calculate the local heat transfer coefficients of the representative fin regions. Pressure drop and heat transfer experiments were performed for a co-rotating fin pattern varying the duct height from 20-50 mm. The friction factor calculated from the pressure drop shows that comparatively larger friction occurs for the smaller duct cases and the friction factor slowly decreases with increasing Reynolds number. The effect of duct height on the area-averaged heat transfer results show that heat transfer initially increases with duct height and then finally decreases with increasing the duct height. Detailed heat transfer analysis and iso-heat transfer coefficient contour gives a clear picture of heat transfer characteristics of the overall surface. The relative performance graph indicates that a 25 mm duct is the optimum duct height for the highest thermal performance. In addition. a significant thermal enhancement, 2.8-3.8 times the smooth surface, can be achieved at lower Reynolds number with a co-rotating fin pattern in the duct. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:348 / 356
页数:9
相关论文
共 15 条
[1]  
Bergles A.E., 1974, Proceedings of the Fourth International Heat Transfer Conference, V2, P239
[2]  
Bilen K, 2002, HEAT MASS TRANSFER, V38, P649, DOI 10.1007/S002310100275
[3]   Study on heat transfer and fluid flow characteristics with short rectangular plate fin of different pattern [J].
Didarul, Islam Md. ;
Kenyu, Oyakawa ;
Minoru, Yaga ;
Izuru, Senaha .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2007, 31 (04) :367-379
[4]   Investigation of turbulent heat transfer and fluid flow in longitudinal rectangular-fin arrays of different geometries and shrouded fin array [J].
El-Sayed, SA ;
Mohamed, SM ;
Abdel-latif, AM ;
Abouda, AE .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2002, 26 (08) :879-900
[5]   LOCAL HEAT-TRANSFER FROM A SQUARE PRISM TO AN AIRSTREAM [J].
IGARASHI, T .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1986, 29 (05) :777-784
[6]   Heat transfer enhancement from a surface affixed with rectangular fins of different patterns and arrangement in duct flow [J].
Islam, Md. Didarul ;
Oyakawa, Kenyu ;
Yaga, Minoru .
JOURNAL OF ENHANCED HEAT TRANSFER, 2008, 15 (01) :31-50
[7]  
KADLE DS, 1986, ASME, V108, P16
[8]   A CORRELATION FOR HEAT-TRANSFER AND WAKE EFFECT IN THE ENTRANCE REGION OF AN IN-LINE ARRAY OF RECTANGULAR BLOCKS SIMULATING ELECTRONIC COMPONENTS [J].
MOLKI, M ;
FAGHRI, M ;
OZBAY, O .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1995, 117 (01) :40-46
[9]   Fluid Flow and Infrared Image Analyses on Endwall Fitted with Short Rectangular Plate Fin [J].
Oyakawa, Kenyu ;
Didarul, Islam Md ;
Yaga, Minoru .
JOURNAL OF THERMAL SCIENCE, 2006, 15 (02) :145-151
[10]   HEAT-TRANSFER PERFORMANCE COMPARISONS OF 5 DIFFERENT RECTANGULAR CHANNELS WITH PARALLEL ANGLED RIBS [J].
PARK, JS ;
HAN, JC ;
HUANG, Y ;
OU, S ;
BOYLE, RJ .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (11) :2891-2903