Structural health monitoring of the Tamar suspension bridge

被引:167
作者
Koo, K. Y. [1 ]
Brownjohn, J. M. W. [1 ]
List, D. I. [2 ]
Cole, R. [2 ]
机构
[1] Univ Sheffield, Sheffield S1 3JD, S Yorkshire, England
[2] Tamar Bridge & Torpoint Ferry Joint Comm, Plymouth, Devon, England
基金
英国工程与自然科学研究理事会;
关键词
structural health monitoring; suspension bridges; environmental effects; MODAL PARAMETER-IDENTIFICATION; FULL-SCALE MEASUREMENT; TYPHOON; EXCITATION; VIBRATION;
D O I
10.1002/stc.1481
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents experiences and lessons from the structural health monitoring practice on the Tamar Bridge in Plymouth, UK, a 335-m span suspension bridge opened in 1961. After 40years of operations, the bridge was strengthened and widened in 2001 to meet a European Union Directive to carry heavy goods vehicles up to 40tonnes by a process in which additional stay cables and cantilever decks were added and the composite deck was replaced with a lightweight orthotropic steel deck. At that time, a structural monitoring system comprising wind, temperature, cable tension and deck level sensors was installed to monitor the bridge behaviour during and after the upgrading. In 2006 and 2009, respectively, a dynamic response monitoring system with real-time modal parameter identification and a robotic total station were added to provide a more complete picture of the bridge behaviour, and in 2006 a one-day ambient vibration survey of the bridge was carried out to characterize low-frequency vibration modes of the suspended structure. Practical aspects of the instrumentation, data processing and data management are discussed, and some key response observations are presented. The bridge is a surprisingly complex structure with a number of inter-linked loadresponse mechanisms evident, all of which have to be characterized as part of a long-term structural health monitoring exercise. Structural temperature leading to thermal expansion of the deck, main cables and additional stays is a major factor on global deformation, whereas vehicle loading and wind are usually secondary factors. Dynamic response levels and modal parameters show apparently complex relationships among themselves and with the quasi-static load and response. As well as the challenges of fusing and managing data from three distinct but parallel monitoring systems, there is a significant challenge in interpreting the load and response data firstly to diagnose the normal service behaviour and secondly to identify performance anomalies. Copyright (c) 2012 John Wiley & Sons, Ltd.
引用
收藏
页码:609 / 625
页数:17
相关论文
共 28 条
[1]  
[Anonymous], 1996, SUBSPACE IDENTIFICAT, DOI DOI 10.1007/978-1-4613-0465-4
[2]  
[Anonymous], FHWARD86183
[3]  
[Anonymous], 2004, SIGKDD, DOI DOI 10.1145/1014052.1014104
[4]  
Brownjohn J. M. W., 2008, IABMAS08
[5]   HUMBER BRIDGE FULL-SCALE MEASUREMENT CAMPAIGNS 1990-1991 [J].
BROWNJOHN, JMW ;
BOCCIOLONE, M ;
CURAMIE, A ;
FALCO, M ;
ZASSO, A .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 1994, 52 (1-3) :185-218
[6]  
Brownjohn JMW, 2007, IMAC
[7]  
Brownjohn JMW, 2001, ASSESSMENT STRUCTURA
[8]  
Carder D.S., 1937, B SEISMOL SOC AM, V27, P267, DOI [DOI 10.1785/BSSA0270040267, 10.1785/BSSA0270040267]
[9]   Modal parameter identification of Tsing Ma suspension bridge under typhoon victor: EMD-HT method [J].
Chen, J ;
Xu, YL ;
Zhang, RC .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2004, 92 (10) :805-827
[10]   Dynamic testing of Alfred Zampa Memorial Bridge [J].
Conte, Joel P. ;
He, Xianfei ;
Moaveni, Babak ;
Masri, Sami F. ;
Caffrey, John P. ;
Wahbeh, Mazen ;
Tasbihgoo, Farzad ;
Whang, Daniel H. ;
Elgamal, Ahmed .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (06) :1006-1015